U S E R ’ S M A N U A L MI M- D0 0 D M S ( Da t a M an ag em e n t S erv e r) DB98-29777A(4) E K C CHINESE ENGLISH.
E- 2 Sa f e t y P r e c a u ti o n s Do n ot a tt e mp t to i ns ta ll o r re pa ir t hi s DM S by y ou rs el f . T hi s D MS c o n ta in s no u se r- se rvi ce ab le p art s. A lw a ys c on su lt a ut ho ri z e d se rvi c e pe rs on ne l fo r r e pa ir s .
E- 3 ENGLISH C o n t e n t s Gene ral Descri ptio n I NT RO DU CT IO N O F DM S . . . . . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . .. .. . .. . 4 A DV A NT A G E S OF D M S S Y ST E M .
E- 4 Ge n er a l D e s c r ip ti o n I NT RO DU CTI ON OF DM S ( D A T A M AN A GE ME NT S E RV ER ) The DMS is an Interne t based devic e for cen tral mana gemen t of Samsu ng syst em air-condi tione rs. It supports LAN & W A N and oper ates 24 hours without a separa te PC.
E- 5 ENGLISH Ge n er a l D e s c r ip ti o n T ER MS DM S The abbr eviatio n of Data Managemen t Ser ver . U P PE R C ON T RO LL ER It means S-NET Series , a local contr oller of the DVM system . S-NET 3, S-NET mini and S-NET i are linked to a DMS.
E- 6 Devi ce T y pe Indoor Unit Indoor unit communic ation error Indoor unit sensor rela ted err or Other error s Outd oor Unit Outd oor unit comm unica tion err or Pi pe inspectio n error Outd oor un.
E- 7 ENGLISH M ai n F u n ct io n Item C onten t Remar k Schedu le P eriod Starting and ending date of a sched ule Ex cept ion Day Setup Set an exc eption day within a schedul e period to igno re the .
E- 8 M ai n F u n ct io n ( C o n ti n u ed ) Ov e rvi ew The DMS c alcula tes and d istribu tes the po wer c onsume d by each indoor unit by rec eiving th e tot al po wer usa ge fr om the w att- hour m eter int er fac e modu les (S IM) and t aking in to ac count t he op erat ion st atus of th e indo or uni ts.
E- 9 ENGLISH M ai n F u n ct io n ( C o n ti n u ed ) Tim e seg mentatio n is used t o divide 24 hou rs in to d iff eren t sections and to di stribu te po wer ac cor ding to each s ection.
E- 10 U s i ng t h e D MS t hr o ug h t he W eb Ref er to “3.2 .9 Set ting an d View ing the Sys te m En vir onmen t ” or the ins tal la tio n manu al on how to se t the IP add re ss of the DMS . Setti ng t he W eb En vir onme nt I nstal l JRE 1.
E- 11 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb Login Function Details L ogin allo ws only author ized users to a cce ss the we b page . There is no limi t on t he num ber o f user s tha t can acc ess t he DMS at t he sam e tim e, h ow ever , less t han 5 users are rec ommended for acc ess s peed r easons .
E- 12 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Details On t his sc ree n user s can monit or th e ope rati on sta tus o f all indoo r units and c ontrol each indoo r unit . (But , if the ERV s yst em is instal led , can c heck t he wh ole ERV c ontrol stat us.
E- 13 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) M o ni t o r in g an d C on t r ol 2 Se le ct a nd cl ic k o n t he in do or un it an d th e b ac kg ro und co lo r of th e i nd oo r u ni t i s c ha ng ed to gr ee n. T he op er a ti on st at us of th e s el ec t ed ind oo r un it is di sp la ye d on th e u pp er pa rt.
E- 14 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 3 En ab le /D is ab le Re mo te C on tr ol . W he n p r es si ng th e bu tt on, se le cte d i nd oo r u ni t w il l b e u nd erl in ed . W he n p r es si ng th e bu tt on , u nde rl in e o n s el ec te d i nd oo r u ni t w il l di sa pp ea r .
E- 15 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 5 [ C ur r en t T em pe ra tu r e] Se le ct i on . Wh en se le cti ng t he ch ec k b o x, di sp la y t he cu rr en t t e mp er a t ur e o f t h e wh ol e i ns ta ll ed in do or un it s .
E- 16 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Details On t his sc ree n user s can monit or th e ope rati on sta tus o f all ERV s and con trol each ERV . M o ni t o r in g an d C on t r ol ( ER V S y st em ) Monitoring and Control 1 The status of all ERVs can be viewed from the ‘Monitor all indoor units.
E- 17 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) M o ni t o r in g an d C on t r ol ( ER V S y st em ) 2 Se le ct a nd cl ic k o n t he ERV an d t he ba ck gr ou nd co lo r o f th e ER V i s ch an ged to gr ee n. Th e o pe ra ti on st at us of th e s el ec t ed ER V i s di sp la y ed on th e u pp er pa rt.
E- 18 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 3 E na bl e Re mo te C on tr ol /D is ab le Re mo t e C on tr o l . Wh en pr es si ng th e b ut to n, ca nn ot c on tr o l t he ERV b y t he w ir e d r em ot e c on tr o l i n e ac h r oo m a n d ca n c on t r ol t he E RV on ly on th e D MS w e bp ag e s cr e en .
E- 19 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 5 [ C ur r en t T em pe ra tu r e] Se le ct i on . Wh en se le cti ng t he ch ec k b o x o n t he ER V sy s t e m, d is pl a y wi th “- -” . In or d er t o r et ur n t o t he mo ni to ri ng sc re en , s el ec t a ga in th e [ C ur re n t T em p e r a t ur e .
E- 20 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Details T he DMS u ser s c an vi ew an d d ele te er ro r his tory o f t he DVM sy st em. The DMS s ave s up to 2 56 erro rs . V i ew E rr o r Hi st o ry 1 All er ror histor y can be checked from the ‘View Error Histor y ’ page.
E- 21 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) V i ew E rr o r Hi st o ry Function Details Us ers can se t, ed it, a nd del et e s ched ule s f or co ntr olli ng t he DVM sy st em.
E- 22 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) On th e Crea te Ne w Sched ule scre en, use rs c an se t the Sche dul e Nam e, Sched ule Pe riod , App lied Ind oor Unit , and E ve nt . 1 F or the event, users can set the Repeat or not, Day , On T ime, Off Time , T emperature , Mode, ER V Mode and Remote Control Allow or not.
E- 23 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 3 W he n p r es si ng th e ‘ Se le ct i nd oo r u ni t’ bu tt on fr om th e , us er s c an se le ct th e s ch ed ul e in do or u ni t.
E- 24 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Explanation Us ers can se t, in qui r e, an d ed it the i nf orm at ion of pow er dis tribu tio n se ctio n. Ref er t o p g. 4 f or mor e in f orm ati on o n t he P ow er Dis tribu ti on F unct ion .
E- 25 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Se tt in g an d V i ew in g th e P o w er D is tr ib ut io n F u n ct i on 4 3 S e ct io n s a re c l a s s i f i e d i nt o S e ct io n A , S e ct io n B , a n d S e ct io n C .
E- 26 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Explanation Us ers can vi ew or ed it th e c onne ctio n b etwee n th e i ndo or un its and ass ign ed w at t- hou r m et er . DM S w ill dis trib ute po wer based on the inf orma tion which has be en set u p fr om t his me nu.
E- 27 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 2 Ch ec k t he in do or /o ut do or u ni ts co nne ct ed to th e w a tt -h our me te r . 3 Check the SIM transmitter channel (watt-hour meter). If the indoor unit power is supplied from the outdoor unit, set the ‘Outdoor SIM ch.
E- 28 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) No te In do or /Ou td oo r u ni t SI M c ha nne l s et ti ng - If t he re is SI M tr an sm it te r c onn ect ed to th e D MS, us er c an se t u p t he SI M ch an ne l.
E- 29 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Explanation Us ers can in qu ir e o pe ra tio n b rea kdo wns and po wer us age by ind oor uni ts th at is sa ved in t he D MS.
E- 30 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Ind ividu al Ind oor unit (b y per iod) 1 Select ‘Individual indoor units (by date)’ in to check the power consumption and the running rate by date for individual indoor unit.
E- 31 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) V i ew in g P o w e r D is tr ib ut io n Re su lt 1 Click ‘SETUP FOR POWER DISTRIBUTION’ on the DMS web page. 2 W he n t he V i rtu al c ha nn el f or t he In do or /O ut doo r u ni t i s s et , ab ov e s cr een wi ll ap pe ar .
E- 32 4 Ch ec k t he r es ul t o f p o w er di st rib ut ion . Cl ic k ‘S ear ch ’ to re-e nt er th e p ow er usa ge f or e ac h c ha nn el . Cl ic k ‘S av e A s F il e ’ to sa v e th e r es ul t a s e xc el fil e. Se le ct ‘ ra te ’ to ch ec k t he r es ul t o f p ow er di st ri bu ti on in r at e .
E- 33 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Explanation T he DMS u ser s c an r est rict th e i ndoo r u nit as c ool onl y or he at onl y . Setti ng th e In door Unit Res triction Setting the Indoor Unit Restriction 1 Click ‘RESTRICTED INDOOR UNIT USE’ on the DMS web page.
E- 34 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 3 Cl ic k [ ] t o s el ect op er at io n m od e l im it . Us er s c an se lec t ‘ No ne ’ , ‘ C oo l o nl y’ or ‘H ea t o nl y’ .
E- 35 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 5 Se t lo w er li mi t t emp er at ur e( C oo l) . Y ou ca n s et the lo we r li mi t t em pe ra tu re b y s el ec ti ng ‘ Ca nc el ’ or ‘ App ly’ .
E- 36 Not e Mix ed ope ra tio n ca n occu r ev en if you set c ontro l mode li mit . If the in door un it wi th c ont ro l mode lim it is in mix ed ope ra tion, DMS wi ll solv e the pro ble m aut omati ca lly by c ontro lling it in c ontro l mode li mit .
E- 37 ENGLISH Function Explanation T he DMS u ser s c an se t a nd vi ew in fo rma tion r ela ted to t he DMS sy st em insta llat ion and oper at ion . (The insta ller must c omp let e the sys te m e nvi ro nme nt s etu p whe n in sta lli ng th e D MS .
E- 38 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 1 DMS Net work Information Change the set information by inquiring the existing set network information from the DMS network information and clicking the ‘Edit’ button. I f this information is changed, the DMS is restar ted automatically .
E- 39 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 6 Send erro r report email In order to send automat ically to an e -mail when an error of the air cond itione r is occurr ed, inpu t an e -mail addre ss, ID , passw ord, and SMTP server info rmatio n by clicking the ‘Edit’ butt on.
E- 40 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Setting the Operation mode of A/C Running LED 1 Click ‘SY STEM ENVIRONMENT ’ on the DMS web page. 2 Cl ic k ‘ E di t’ on the Op er at io n m ode of A/ C R un ni ng LE D . ‘ Ed it’ wi ll cha ng e t o ‘S av e ’ .
E- 41 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 1 Check the setting histor y from the Log window . DMS saves maximum 256 histories of each setting. If the number of histor y exceeds 256, DMS will delete the oldest histor y .
E- 42 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) Function Details T r acki ng is the m ost i niti al sta ge th at a DM S re co gn iz es the DVM in doo r/ out door un its . Wh en perform ing a T rac king , so me inf orm ati on m ay be lo st; t hus , u se with car e.
E- 43 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 2 When the T r acking P assw ord Input window appears , enter the passw ord. 3 When the T racking Confirm window appears, press ‘C onfirm ’ . T racking will star t. MIM-D00_IB_E_29777-2.
E- 44 U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 4 Notification with ‘Now track ing, please wait ’ sign will appear . T racking may take from few seconds up to 3 minutes. T racking time may differ depending on the number for controllers.
E- 45 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) 6 Enter the name of the centralized controller and the indoor units. 7 Pr ess ‘Sav e ’ . Changed name of the centralized controller and the indoor unit will be saved on DMS.
E- 46 Note Do not run T racking ex cept for the fo llow ing cond itions : A ft er i ni ti al in st al la ti on . - A ft er i ni ti al i ns t a ll at io n, r un T r a ck i ng f o r D M S t o r e c o g n iz e th e in st al la ti on s tr uct ur e .
E- 47 ENGLISH U s i ng t h e D MS t hr o ug h t he W eb ( C o n ti n u ed ) U se r Ma na ge me n t 1 Click ‘USER MANAGEMENT’ on the DMS web page. 2 W he n U ser Man ag em en t sc re en ap pe ar s, en t er us er ID , P as sw or d an d De sc ri pt io n.
E- 48 1 Click ‘USER MANAGEMENT’ on the DMS web page. 2 W he n U ser Man ag em en t sc re en ap pe ar s, se le ct t he us er yo u wi sh t o e di t. Y ou ca n s el ect nu mb er of us er s a t o nc e o r se le ct in di vi du al us er . 3 E di t t he P as sw or d a nd th e D es cr ip ti on on se le ct ed ID .
E- 49 ENGLISH 1 Click ‘USER MANAGEMENT’ on the DMS web page. 2 W he n U ser Man ag em en t sc re en ap pe ar s, se le ct t he us er yo u wi sh t o d el et e. Y ou ca n s el ect nu mb er of us er s a t o nc e o r se le ct in di vi du al us er .
E- 50 This product uses soft wares distributed under GPL and LGPL liscense. Therefor e, you can receive the source code of GPL and L GPL used in this product by requesting the email address below . E-mail : oss.request@samsung.c om GPL S oft ware - Monta Vista Linux Kernel 2.
E- 51 ENGLISH So ft w ar e Berkeley DB software is used in this product. The source code of Berkeley DB software can be received when request to the following email address or can be downloaded from the website. E-mail: oss.request@samsung.com Berkeley DB software : db-3.
MIM-D00_IB_E_29777-2.indd 52 2009-05-08 ソタタ・10:08:14.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Samsung MIM-D00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Samsung MIM-D00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Samsung MIM-D00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Samsung MIM-D00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Samsung MIM-D00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Samsung MIM-D00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Samsung MIM-D00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Samsung MIM-D00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.