Manuale d’uso / di manutenzione del prodotto IM708 del fabbricante Lincoln Electric
Vai alla pagina of 38
INVERTEC V350-PRO (CE) OPERA TOR’S MANUAL For use with machines Code; 10670 IM708 January, 2001 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’ s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les pr é cautions de s û ret é specifiques qui parraissent dans ce manuel aussi bien que les pr é cautions de s û ret é g é n é rales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v SAFETY v V350-PRO (CE) L10093 3-1-96H Conf or mance standard: EN 50 199 Electromagnetic Compatibility (EMC) Product Standard f or Arc Welding Equipment. It All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be received b y other equipment, electrical interference ma y result.
vi SAFETY vi V350-PRO (CE) The size of the surrounding area to be considered will depend on the structure of the building and othe r Methods of Reducing Emissions Consideration should be giv en to shielding the supply cable of permanently installed welding equipmen t conduit or equivalent.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
viii viii T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ..................................................................
V350-PRO (CE) A-1 INST ALLA TION A-1 TECHNICAL SPECIFICA TIONS - INVERTEC V350-PR O (CE) INPUT A C V OL T A GE & DC OUTPUT OUTPUT CABLES, CONNECTIONS AND LIMIT A TIONS Product Ordering Input AC Rated DC Output Output Weight Dimensions Name Information Voltage Amps/Volts/Duty Cycle Range with Cord HxWxD 50/60 Hz (continuous) 350A / 34V / 60% 14.
A-2 INST ALLA TION A-2 SELECT SUIT ABLE LOCA TION The Invertec V350-PRO (CE) will operate in harsh environments. Even so, it is important that simple pre- ventative measures are followed in order to assure long life and reliable operation.
A-3 INST ALLA TION A-3 V350-PRO (CE) LN-10 Connection Instructions • Turn the Invertec power switch "off". • Connect the K1505 control cable from the LN-10 to the Invertec 24/42VAC 14-pin amphenol connector on the rear of the Invertec. • Connect the electrode cable to the output terminal of polarity required by the electrode.
A-4 INST ALLA TION A-4 V350-PRO (CE) PARALLEL OPERATION The V350-PRO (CE) are operable in parallel in CC mode. For best results, the currents of each machine should be reasonably well shared.
B-1 OPERA TION V350-PRO (CE) B-1 SAFETY PRECA UTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. ------------------------------------------------------------------------ FUMES AND GASES can be danger- ous.
B-2 OPERA TION B-2 5. THERMAL • This status light indicates when the power source has been driven into thermal overload. If the output terminals were "ON", the "ON" light will blink indicat- ing that the output will be turned back on once the unit cools down to an acceptable temperature level.
B-3 OPERA TION B-3 • The Arc Control regulates the relative Slope of the process. Slope dynamically controls the force the arc has to penetrate an open root.
B-4 OPERA TION B-4 TIG mode • The remote will default to the 6-pin amphenol if a remote control is connected to the 6-pin amphenol and one of the 14-pin amphenols. If a remote is not connected to the 6-pin amphenol then the remote will default to the 14-pin amphenols if a remote is connected to one of the 14-pin amphenols.
B-5 OPERA TION B-5 AUXILIARY POWER • 115VAC, 42VAC and 24VAC power is available from the two 14-pin amphenols on the rear of the unit. (K1728-2 Construction model of the Invertec V350-PRO (CE) does not have the amphenols) These supplies are intended to supply power for auxiliary equipment like wire feeders and the TIG Module.
C-1 A CCESSORIES C-1 OPTIONS / A CCESSORIES "CE" VERSION – K1728-3 • The "CE" version is the Factory version with the addition of power line filtering allowing the machine to comply with the European and Australian EMC emission requirements.
D-1 MAINTENANCE D-1 VISUAL INSPECTION Clean interior of machine with a low pressure air stream. Make a thorough inspection of all compo- nents. Look for signs of overheating, broken leads or other obvious problems. Many problems can be uncovered with a good visual inspection.
E-1 TR OUBLESHOO TING E-1 V350-PRO (CE) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 V350-PRO (CE) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TR OUBLESHOO TING E-3 V350-PRO (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TR OUBLESHOO TING E-4 V350-PRO (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TR OUBLESHOO TING E-5 V350-PRO (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIA GRAMS F-1 V350-PRO (CE) TURN THE POWER SWITCH OF THE WELDING POWER SOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLES OR WHEN CONNECTING OR DISCONNECTING PLUGS TO WELDING POWER SOURCE.
F-2 DIA GRAMS F-2 V350-PRO (CE) N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
F-3 DIA GRAMS F-3 V350-PRO (CE) N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
F-4 DIA GRAMS F-4 V350-PRO (CE) N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION. N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF", REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE. N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
F-5 DIA GRAMS F-5 V350-PRO (CE) Only qualified persons should install, use or service this machine. using the disconnect switch at the fuse box WARNING Turn off input power to the Welding Power Source Before connecting the wire feeder. ELECTRIC SHOCK CAN KILL N.
F-6 DIA GRAMS F-6 V350-PRO (CE) Only qualified persons should install, use or service this machine. using the disconnect switch at the fuse box WARNING Turn off input power to the Welding Power Source Before connecting the wire feeder. ELECTRIC SHOCK CAN KILL N.
F-7 DIA GRAMS F-7 V350-PRO (CE) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-8 DIA GRAMS F-8 V350-PRO (CE) 1 4.7 9 1 2.4 4 3.44 21.60 27.82 5.50 10.0 0 MOUNTING HOLE LOCATIONS M19527 13.1 0 1/4- 20 NUT (4 PLAC ES) NOTE: MOUNTING SCREWS CA 8/00 N NOT PROTR UDE MORE THAN 0.
NO TES.
Now A vailable...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lincoln Electric IM708 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lincoln Electric IM708 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lincoln Electric IM708 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lincoln Electric IM708 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lincoln Electric IM708, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lincoln Electric IM708.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lincoln Electric IM708. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lincoln Electric IM708 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.