Manuale d’uso / di manutenzione del prodotto OM-945 del fabbricante Hobart Welding Products
Vai alla pagina of 68
Champion 10,000 Pro cesses Descrip ti on Stick (SMAW) W elding Engine Driven Welding Generator OM -945 194 047AD 2007 − 05 ™.
Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1 or visit our website at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS SECTION 9 − MAINTENANCE − (KOHLER-POWERED UNITS) 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1. Routine Maintenance (Kohler-Powered Units) 32 . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-945 Page 1 SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING rom_2007 − 04 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-945 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. Keep your head out of the fumes. Do not breathe the fumes. If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-945 Page 3 1-3. Engine Hazards BA TTER Y EXPLOSION can BLIND. Always wear a face shield, rubber gloves, and protective clothing when working on a battery . Stop engine before disconnecting or connect- ing battery cables or servicing battery .
OM-945 Page 4 HOT MET AL from air arc cutting and gouging can cause fire or explosion. Do not cut or gouge near flammables. W atch for fire; keep extinguisher nearby . HOT P ARTS can cause burns and injury . Do not touch hot compressor or air system parts.
OM-945 Page 5 H. F . RADIA TION can cause interference. High-frequency (H.F .) can interfere with radio navigation, safety services, computers, and communications equipment. Have only qualified persons familiar with electronic equipment perform this installation.
OM-945 Page 6 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION rom_2007 − 04fre Se protéger , ainsi que toute autre personne travaillant sur les lieux, contre les étincelles et le métal chaud.
OM-945 Page 7 Une tension DC importante subsiste à l’intérieur des onduleurs après avoir coupé l’alimentation. Couper l’alimentation du poste et décharger les condensateurs d’entrée comme indiqué dans la Section Maintenance avant de toucher des composants.
OM-945 Page 8 Suivre les recommandations dans OSHA 1910.252(a)(2)(iv) et N F P A 51B pour les travaux à chaud et avoir de la surveillance et un extincteur à proximité. LE BRUIT peut affecter l’ouïe. Le bruit des processus et des équipements peut affe c l’ouïe.
OM-945 Page 9 Dévisser le bouchon légèrement et laisser la vapeur s’échapper avant d’enlever le bouchon. L ’utilisation d’un groupe autonome à l’intérieur PEUT VOUS TUER EN QUELQUES MINUTES. Le s fumées d’un groupe autonome contient du monoxyde de carbone.
OM-945 Page 10 LE SURCHAUFFEMENT peut endom- mager le moteur électrique. Arrêter ou déconnecter l’équipement avant d e démarrer ou d’a rrêter le moteur . Ne pas laisser tourner le moteur trop lentement sous risque d’en - dommager le moteur électrique à cause d’une tension et d’une fré - quence trop faibles.
OM-945 Page 1 1 2-6. P r oposition californienne 65 A vertissements Les équipements de soudage et de coupage produisent des fumées et des gaz qui contiennent des produits chimiques dont l’État de Californie reconnaît qu’ils provoquent des mal- formations congénitales et, dans certains cas, des cancers.
OM-945 Page 12 SECTION 3 − DEFINITIONS 3-1. Symbol Definitions Stop Engine Fast (Run, W eld/Power) Fast/Slow (Run/Idle) Slow (Idle) Start Engine Read Operator’s Manual A Amperes V V olts Engine Oi.
OM-945 Page 13 4-2. Dimensions, Weights, and Operating Angles Dimensions Height 33-1/2 in (851 mm) A Width 18-1/2 in (470 mm) A B C ! Depth 38 in (965 mm) B C D G ! Do not move or operate unit where it could tip. A 18 in (457 mm) D G 4 HOLES w here it co u ld tip .
OM-945 Page 14 4-4. Fuel Consumption (All Models) 197 254 Continuous Welding 4-5. Duty Cycle 197 148 Duty cycle is the percentage of 10 minutes that unit can weld at rated load without overheating. NOTICE − Exceeding duty cycle ca n damage unit and void warranty .
OM-945 Page 15 4-6. V olt-Ampere Curves 197 253 The volt-ampere curve shows the minimum and maximum voltage an d amperage output capabilities of th e welding generator . Curves of a ll other settings fall between the curves shown. Notes 16 Gauge (.063 in) 22 Gauge (.
OM-945 Page 16 SECTION 5 − INST ALLA TION ! Do not lift unit from end. ! Do not weld on base. W elding on base can cause fuel tank fire or explosion. Bolt unit down using holes provided in base ! Always securely fasten weld- ing generator onto transport vehicle or trailer and comply with all DOT and other applica- ble codes.
OM-945 Page 17 5-2. Engine Prestart Checks (Robin-Powered Units) 802 353-G Full Gasoline Check all fluids daily . Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil. Engine stops if oil pressure gets too low . Follow run-in procedure in engine manual.
OM-945 Page 18 ! Always wear a face shield, rubber gloves and protec- tive clothing when working on a battery . Remove battery from unit. 1 V ent Caps 2 Sulfuric Acid Electrolyte (1.265 Specific Gravity) 3 W ell Fill each cell with electrolyte to bottom of well (maximum).
OM-945 Page 19 5-6. Installing Exhaust Pipe 801 681 / Ref. 226 427-A ! Engine backfire can cause se- vere burns or other injuries. Do not point exhaust pipe to- ward control panel. Keep away from exhaust outlet. Point exhaust pipe in desired di- rection but always away from front panel and direction of travel.
OM-945 Page 20 5-8. Connecting T o Weld Output T erminals 803 778-A / Ref. 226 427-A T ools Needed: 4 2 3 Do not place anything between Correct Installation Incorrect Installation 1 weld cable terminal and copper bar .
OM-945 Page 21 SECTION 6 − OPERA TING THE WELDING GENERA TOR If the unit is extremely overloaded, weld and generator power will stop. T urn unit off and restart to reset the generator prote ction circuit and restore weld generator power output.
OM-945 Page 22 6-2. Cold Weather Engine Operation Ref. 226 427-A 1 Engine Control Switch Carburetor Icing Carburetor icing causes the unit to drop below the normal idle speed and then stall. This condition occurs when the temperature is near freezing and the rela- tive humidity is high.
OM-945 Page 23 SECTION 7 − OPERA TING AUXILIAR Y EQUIPMENT If the unit is extremely overloaded, weld and generator power will stop. T urn unit off and restart to reset the generator prote ction circuit and restore weld generator power output.
OM-945 Page 24 7-2. Optional Generator Power Receptacles ! If unit does not have GFCI re- ceptacles, use GFCI- protected extension cord. Combined output of all receptacles limited to 10 kV A/kW rating of the generator .
OM-945 Page 25 7-3. Wiring Instructions For Optional 240 V olt, Single-Phase Plug (NEMA 14-50P) plug1 1 1/03 − 120 813-D The plug can be wired for a 240 V , 2-wire load or a 120/240V , 3-wire load.
OM-945 Page 26 SECTION 8 − MAINTENANCE (ROBIN-POWERED UNITS) 8-1. Routine Maintenance (Robin-Powered Units) ! Stop engine before maintaining. S ee Engine Manual and Maintenance Label for important start-up, service, and storage information. Service engine more often if used in severe conditions.
OM-945 Page 27 8-2. Maintenance Label (Robin-Powered Units).
OM-945 Page 28 8-3. Servicing Air Cleaner (Robin − Powered Units) aircleaner3 1 1/04 − 803 070 / S-0759 oil 1 2 ! Stop engine and let cool. NOTICE − Do not run engine with- ou t air cleaner or with dirty element. 1 W rapper Wash wrapper with soap and water solution.
OM-945 Page 29 8-4. Overload Protection (Robin-Powered Units) 802 342 / Ref. 802 353-G ! Stop engine. Disconnect nega- tive ( − ) battery cable. If the unit is extremely over- loaded, weld and generator pow- er will stop. T urn unit off and re- start to reset the generator protection circuit and restore weld and generator power output.
OM-945 Page 30 ! Stop engine and let cool. 1 Oil Drain V alve 2 1/2 ID x 7 in Hose 3 Oil Filter Change engine oil and filter ac- cording to engine owner’s manual. ! Close valve and valve cap before adding oil and running engine. Fill crankcase with new oil to full mark on dipstick (see Section 8- 2).
OM-945 Page 31 8-7. Adjusting Engine Speed (Robin-Powered Units) 802 353-G / 802 457 After tuning engine, check engine speeds with a tachometer (see table). If necessary , adjust speeds as follows: Start engine and run until warm. Remove wrapper to access speed adjustments.
OM-945 Page 32 SECTION 9 − MAINTENANCE − (KOHLER-POWERED UNITS) 9-1. Routine Maintenance (Kohler-Powered Units) ! Stop engine before maintaining. S ee Engine Manual and Maintenance Label for important start-up, service, and storage information.
OM-945 Page 33 9-2. Maintenance Label (Kohler-Powered Units).
OM-945 Page 34 9-3. Servicing Air Cleaner (Kohler − Powered Units) aircleaner3 1 1/04 − 802 772 / S-0759 oil 1 2 ! Stop engine and let cool. NOTICE − Do not run engine with- ou t air cleaner or with dirty element. 1 W rapper Wash wrapper with soap and water solution.
OM-945 Page 35 9-4. Overload Protection (Kohler-Powered Units) Ref. 801 221-B / Ref. 802 353-G ! Stop engine. If the unit is extremely over- loaded, weld and generator pow- er will stop. T urn unit off and re- start to reset the generator protection circuit and restore weld and generator power out- put.
OM-945 Page 36 9-6. Changing Engine Oil, Oil Filter , and Fuel Filter (Kohler-Powered Units) 802 339-G / S-0842 T ools Needed: 3 4 5 1 2 Full ! Stop engine and let cool. 1 Oil Drain V alve 2 1/2 ID x 7 in Hose 3 Oil Filter Change engine oil and filter ac- cording to engine owner’s manual.
OM-945 Page 37 9-7. Adjusting Engine Speed (Kohler-Powered Units) 802 339-G / 801 209-A After tuning engine, check engine speeds with a tachometer (see table). If necessary , adjust speeds as follows: Start engine and run until warm. Remove wrapper to access speed adjustments.
OM-945 Page 38 SECTION 10 − TROUBLESHOOTING 10-1. T roubleshooting A. Welding T rouble Remedy No weld output. Check control settings. Check weld connections. Reset circuit breaker CB4 (see Section 8-4 or 9-4). Unit overloaded. Stop unit and reduce load.
OM-945 Page 39 T rouble Remedy Erratic power output at generator pow- er ac receptacles. Check fuel level. Check engine speed and adjust if necessary (see Section 8-7 or 9-7). Check receptacle wiring and connections. Have Factory Authorized Service Agent check brushes and slip rings.
OM-945 Page 40 T rouble Remedy During operation in near freezing tem- peratures, engine starts and goes to idle but stalls after a few minutes. T reat fuel with isopropyl alcohol de-icer product. Place Engine Control switch in the Run position until unit has been in operation and loaded for a peri- od of time.
OM-945 Page 41 SECTION 1 1 − ELECTRICAL DIAGRAM 222129 − B Figure 1 1-1. Circuit Diagram For Welding Generator (Robin And Kohler-Powered Units).
OM-945 Page 42 SECTION 12 − GENERA TOR POWER GUIDELINES The views in this section are intended to be representative of all engine-driven welding generators.
OM-945 Page 43 1 Equipment Grounding T erminal 2 Grounding Cable Use #10 AWG or larger insulated copper wire. 3 Ground Device Us e ground device as stated in electrical codes. ! Ground generator to system earth ground if supplying power to a premises (home, shop, farm) wiring system.
OM-945 Page 44 12-5. Approximate Power Requirements For Industrial Motors Industrial Motors Rating Startin g W atts Running W atts Split Phase 1/8 HP 800 300 1/6 HP 1225 500 1/4 HP 1600 600 1/3 HP 210.
OM-945 Page 45 12-7. Approximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running W atts Hand Drill 1/4 in 350 350 3/8 in 400 400 1/2 in 600 600 Circular Saw 6-1/2 .
OM-945 Page 46 12-8. Power Required T o Start Motor Single-Phase Induction Motor Starting Requirements Motor Start Code G H J K L M N P KV A/HP 6.3 7.1 8.0 9.0 10.0 1 1.2 12.5 14.0 S-0624 1 Motor Start Code 2 Running Amperage 3 Motor HP 4 Motor V oltage T o find starting amperage: Step 1: Find code and use table to find kV A/HP .
OM-945 Page 47 12-10. T ypical Connections T o Supply Standby Power T ransfer Switch Essential Loads Fused Disconnect Switch (If Required) Utility Electrical Service 12 3 4 5 W elding Generator Output ! Have only qualified persons perform these connections according to all applicable codes and safety practices.
OM-945 Page 48 12-1 1. Selecting Extension Cord (Use Shortest Cord Possible) Cord Lengths for 120 V olt Loads If unit does not have GFCI receptacles, use GFCI-protected extension cord.
OM-945 Page 49 SECTION 13 − STICK WELDING (SMA W) GUIDELINES 13-1. Stick Welding Procedure stick 2007 − 04 − ST -151 593 ! Weld current starts when electrode touches work- piece. ! Weld current can damage electronic parts in vehicles. Disconnect both battery cables before welding on a vehicle.
OM-945 Page 50 13-2. Electrode and Amperage Selection Chart Ref. S-087 985-A 3/32 1/8 5/32 3/16 7/32 1/4 1/16 5/64 3/32 1/8 5/32 3/16 7/32 1/4 3/32 1/8 5/32 3/16 7/32 1/4 3/32 1/8 5/32 3/16 7/32 1/4 3.
OM-945 Page 51 13-5. Positioning Electrode Holder S-0060 90 ° 90 ° 10 ° -30 ° 45 ° 45 ° GROOVE WELDS FILLET WELDS End View of Work Angle Side View of Electrode Angle End View of Work Angle Side View of Electrode Angle 10 ° -30 ° 13-6.
OM-945 Page 52 13-8. Conditions That Affect Weld Bead Shape Weld bead shape is affected by electrode angle, arc length, travel speed, and thickness of base metal. S-0061 ELECTRODE ANGLE ARC LENGTH TRA VEL SPEED Slow Normal Fast 10 ° - 30 ° Drag T oo Short Normal T oo Long Spatter Angle T oo Small Angle T oo Large Correct Angle 13-9.
OM-945 Page 53 13-10. Butt Joints S-0662 1 T ack Welds Prevent edges of joint from draw- ing together ahead of electrode by tack welding the materials in posi- tion before final weld. 2 Square Groove Weld Good for materials up to 3/16 in (5 mm) thick.
OM-945 Page 54 13-13. Weld T est S-0057-B 1 Vise 2 Weld Joint 3 Hammer Strike weld joint in direction shown. A good weld bends over but does not break. 2 T o 3 in 1/4 in 3 2 1 2 T o 3 in 3 2 1 (51-76 mm) (6.4 mm) (51-76 mm) 13-14. T roubleshooting − Porosity Porosity − small cavities or holes resulting from gas pockets in weld metal.
OM-945 Page 55 13-16. T roubleshooting − Incomplete Fusion Incomplete Fusion − failure of weld metal to fuse completely with base metal or a preceeding weld bead. Possible Causes Corrective Actions Insufficient heat input. Increase amperage. Select larger electrode and increase amperage.
OM-945 Page 56 13-19. T roubleshooting − Burn-Through Burn-Through − weld metal melting completely through base metal resulting in holes where no metal remains. Possible Causes Corrective Actions Excessive heat input. Select lower amperage. Use smaller electrode.
OM-945 Page 57 Notes Welding Symbols Ref. AWS/ANSI A2.4.
OM-945 Page 58 SECTION 14 − P ARTS LIST 6 13 16 15 17 10 8 9 12 14 19 11 23 24 21 27 26 25 28 29 22 18 19 20 − FIG 14-3 5 7 2 3 4 42 43 1 44 − FIG 14-2 18 17 35 36 32 33 34 45 30 31 37 38 39 40 41 Ref. 802 343 − R Hardware is common and not available unless listed.
OM-945 Page 59 Description Part No. Dia. Mkgs. Item No. Figure 14-1. Main Assembly Quantity 1 +193 777 Wrapper 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-945 Page 60 Description Part No. Dia. Mkgs. Item No. Figure 14-1 . Main Assembly (Continued) Quantity 31 181 057 Cover , Base 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-945 Page 61 Description Part No. Dia. Mkgs. Item No. Figure 14-2. Panel, Front w/Components (Figure 14-1 Item 47) Quantity 1 198 122 Stand − of f Support, Pc Card .250w/Post&lock .500 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-945 Page 62 Description Part No. Item No. Figure 14-3. Generator (Figure 14-1 Item 20) Quantity 1 +220 832 Generator Assy , Front (consisting of) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 183 419 O − ring, 1.
Warranty Questions? Call 1-800-332-3281 7 AM − 6 PM EST hobart_warr 2007 − 01 Service Y o u always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281.
PRINTED IN USA © 2007 Hobart Welding Products. 2007 − 01 Hoba rt We lding Pr oducts An Illinois T ool W orks Comp any 600 W est Main Street Tr oy , OH 45373 US A For Technical A ssistan ce: Call1-8.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hobart Welding Products OM-945 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hobart Welding Products OM-945 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hobart Welding Products OM-945 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hobart Welding Products OM-945 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hobart Welding Products OM-945, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hobart Welding Products OM-945.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hobart Welding Products OM-945. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hobart Welding Products OM-945 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.