W all-Mount Power V ector Amplifiers WV100, WV150, & WV250 Models Inst allation and Use Manual © 2002 Bogen Communications, Inc. All rights reserved.
Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. How ev er , information is subject to change. Important Safety Information W ARNING: T o Reduce The Risk of Fire Or Electric Shock, Do Not Expose This Apparatus T o Rain Or Moisture.
Contents Page P ANEL DESCRIPTIONS..................................................................................................2-3 W all-Mount Po w er V ector Front Panel ............................................................................
P anel Descriptions W all-Mount Po wer V ector Fr ont P anel 1 . Input V olume Control Each of the 8 module ba ys are controlled b y an independent v olume contr ol. 2. Signal / Clip Indicator A single two-color LED located abov e each channel’ s volume control indicates the audio activity of that chan- nel’ s input.
P anel Descriptions W all-Mount Po wer V ector Module Bay (Rear) 1 . Module Ba ys The amplifier has eight module ba ys, all of which can accommodate input modules, with two ba ys (ba ys 7 and 8) that can accommodate either input or output modules.
Installation P ackage Contents • Amplifier • 2 Cables • Instruction Manual • Combined XLR receptacle and phone jack • 2 Scre ws (M 3 x 8) • 6 Scre ws (M 4 x 8) Mounting A surface-mount (model BBS) or flush-mount (model BBF shown below) back bo x as w ell as a WMAD door is requir ed for installation.
Modules Module Installation Eight module ba ys are a vailable to accept Bogen’ s new advanced plug-in input modules. Module ba ys 7 & 8 can also accommodate Bogen’ s new advanced plug-in output modules, thereby allo wing users to customize the amplifier to suit the needs of the installation.
Connections Speakers T ransf ormer -Coupled Speaker Connections T ransf ormer -coupled, constant voltage speak er loads ar e connected to their respectiv e load type (i.e ., 70V speak ers to the 70V terminal, 25V speaker systems to the 25V terminals) and the COM terminal.
Connections COM and GND T erminals A shorting jumper typically connects the COM and GND terminals of the amplifier together . The COM terminal is a common lead from the output transformer . For the transformer -coupled speak er output to work, one of the speak er load leads must be connected to this terminal.
8 Connections System Expansion of Po wer V ector Amplifier s Using the bridging RCA connector , it is possible to connect two or mor e Pow er V ector amplifiers. It is not rec- ommended that more than thr ee amplifiers be bridged together due to bridging loss.
Operation Fr ont P anel Controls & Indicators Input V olume Contr ols Each input module ma y be individually controlled by its cor r esponding volume control knob . Signal / Clip Indicator A single LED located above each channel’ s volume contr ol indicates the audio activity of that channel’ s input.
10 Operation Output Limiter The Output Limiter control sets the thr eshold at which the unit hard limits the output signal. Once the Limiter's threshold is exceeded, the output signal is pre vented from incr easing any further .
Block Dia gram 11.
12 Specifications P o wer Output (RMS): WV 1 00: 1 00W ( 1 40W T ypical, @ 1 kHz/0. 1% /4 Ω) WV 1 50: 1 50W (200W T ypical, @ 1 kHz/0. 1% /4 Ω) WV250: 250W (340W T ypical, @ 1 kHz/0. 1% /4 Ω) Fr equency Response T ransf ormer : 45-20 kHz; 0/-2 dB @ FRP Direct: 20-20 kHz; 0/- 1 dB @ FRP Distortion T ransf ormer : 0.
T r oubleshooting 13 • Amplifier not plugged in. • A C outlet dead. • Po w er switch off. • Circuit br eaker tripped. • Speak er connections on amplifier ar e incorr ect. • T rans / Direct Out selector not set corr ectly . • Poor / br oken speak er wiring.
50 S pring S treet, Ramsey , NJ 07446, U.S.A. T el. 201-934-8500, Fax: 201-934-9832, www .bogen.com W arranty Bogen W all-Mount Pow er V ector Amplifiers, modules, and components ar e warranted to be .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bogen WV250 Manual è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bogen WV250 Manual - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bogen WV250 Manual imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bogen WV250 Manual ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bogen WV250 Manual, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bogen WV250 Manual.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bogen WV250 Manual. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bogen WV250 Manual insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.