User s
'
Guide

980389-001 Rev. A



Proprietary Statement This manual contains proprietary information of Zebra Technologies Corporation. It is intended solely for the information and use of parties operating and maintaining the equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to any other parties for any other purpose without the expressed written permission of Zebra Technologies Corporation.
Product Improvements Continuous improvement of products is a policy of Zebra Technologies Corporation. All specifications and signs are subject to change without notice.
FCC Compliance Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
“The user is cautioned that any changes or modifications not expressly approved by Zebra Technologies Corporation could void the user’s authority to operate the equipment.”
Liability Disclaimer Zebra Technologies Corporation takes steps to assure that its published Engineering specifications and Manuals are correct; however, errors do occur. Zebra Technologies Corporation reserves the right to correct any such errors and disclaims liability resulting therefrom.
No Liability for Consequential Damage In no event shall Zebra Technologies Corporation or anyone else involved in the creation, production, or delivery of the accompanying product (including hardware and software) be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or the results of use of or inability to use such product, even if Zebra Technologies Corporation has been advised of the possibility of such damages. Because some states do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.
Trademarks The Zebra logo and the zebra head design are both registered trademarks and R402 is a service mark of ZIH Corp. Windows and MS-DOS are registered trademarks of Microsoft Corp. All other marks are trademarks or registered trademarks of their respective holders.
Copyrights This copyrighted manual and the label printer described herein are owned by Zebra Technologies Corporation. All rights are reserved. Unauthorized reproduction of this manual or the software in the label printer may result in imprisonment of up to one year and fines of up to $10,000 (17 U.S.C.506). Copyright violators may be subject to civil liability.
©2002 ZIH Corp. All rights reserved.




This section describes what you get in your shipping box and provides an overview of printer parts. This section also has procedures that describe how to open and close the printer and report any problems.
Thank you for choosing the Zebra
™Printer, a high-quality thermal transfer on-demand printer with RFID capability manufactured by the industry leader in quality, service, and value—Zebra Technologies Corporation. For over 25 years, Zebra Technologies Corporation has provided customers with the highest caliber of products and support.
This manual provides all of the information you will need to operate your printer on a daily basis. RFID specific ZPL II commands are contained in this manual. To create label formats, refer to the ZPL II Programming Guide (part # 46530L). This guide is available by contacting your distributor or Zebra Technologies Corporation.
driver or label preparation software. Refer to the driver or software documentation for more information.
The Zebra R402 printer, when connected to a host computer, functions as a complete system for printing and encoding “smart” labels, tickets, and tags.


Save the carton and all packing materials in case you need to ship or store the printer later. After unpacking, make sure you have all parts. Follow the procedures for inspecting the printer to familiarize yourself with printer parts so you can follow the instructions in this book.


Look at the outside of the printer and make sure that all parts are present.
To access the media compartment, you must open the printer.
Pull the release levers towards you and lift the cover.




Hold the top cover and press the cover lock to release.
Lower the top cover. The ribbon carriage automatically folds up into place.

If you discover damage or missing parts:

This section describes how to set up your printer for the first time and use the most common operating procedures for loading media in tear-off mode and loading ribbon.
You can operate this printer in two different modes: tear-off or peel-off.
The printer typically uses roll media, but you can use fan-fold media as well.
For procedures to use optional modes and features, refer to the Operation and Options section.

Check the power supply to make certain it is appropriate for your input voltage.
with your printer.
Never operate the printer and power supply in an area where they can get wet. Serious personal injury could result!

When you load media, you must place the roll on the media hangers and then adjust the media guides.
Whether your roll media is inside or outside wound you load it into the printer the same way.


The adjustable guides direct the media toward the platen and print head.


If your media roll has a larger diameter core, you can use an accessory (part number 105810-002) to adapt the core to the media holders.



You must use thermal transfer media (accepts wax and/or resin transferred off a ribbon) when you use a ribbon. When loading ribbon, you install the supply and take-up rolls, then tighten the ribbon on the carriage.
Before following these steps, prepare the ribbon by removing its wrapping and pulling its adhesive strip free.
You can find your first ribbon take-up core in the packing box. Subsequently, use the empty supply core to take up the next roll of ribbon.


You must align the ribbon so that it will be taken straight onto the core.

continuous media, see “Manual Calibration” on page 49.
An auto calibration is performed when the printer is turned on (if media is loaded) or after a media error is cleared. When it is auto calibrating, the printer sets the sensor levels for, and determines the length of, the label you are using.
If the status light flashes red, refer to “Manual Calibration” on page 49.


Press up to turn ON or down to turn OFF the printer.
Takes the printer out of a “pause” condition. (The printer is put into “pause” by either a ZPL II command or an error condition.) See “What the Status Light is Telling You” on page 43.
Use the Feed button for printer setup and status (see “Feed Button Modes” on page 52).
Functions as a printer operational indicator (see “What the Status Light is Telling You” on page 43).

Before you connect the printer to your computer, make sure that the printer is in proper working order. You can do this by printing a configuration label.
If you cannot get this label to print, refer to Troubleshooting on page 43.
Zebr a Technol ogi es ZTC R402- 200dpi
+10 DARKNESS +000 TEAR OFF TEAR OFF PRI NT MODE NON- CONTI NUOUS MEDI A TYPE WEB SENSOR TYPE THERMAL- TRANS. PRI NT METHOD 104 0/ 8 MM PRI NT WI DTH 1233 LABEL LENGTH 22. 0I N 557MM MAXI MUM LENGTH 38400 BAUD 8 BI TS DATA BI TS NONE PARI TY XON/ XOFF HOST HANDSHAKE NONE PROTOCOL 000 NETWORK I D NORMAL MODE COMMUNI CATI ONS 7EH CONTROL PREFI X 5EH FORMAT PREFI X 2CH DELI MI TER CHAR ZPL I I ZPL MODE FEED MEDI A POWER UP FEED HEAD CLOSE DEFAULT BACKFEED +020 LABEL TOP +0000 LEFT POSI TI ON 029 WEB S. 068 MEDI A S. 050 RI BBON S. 050 MARK S. 001 MARK MED S. CS MODES ENABLED . . MODES DI SABLED 832 8/ MM FULL RESOLUTI ON SP. 814. B
FI RMWARE I N THI S PRI NTER I S COPYRI GHTED

This printer comes with a bidirectional parallel data interface. You must supply the required interface cable for your application.
attaching the interface cable.
The power supply barrel connector must be inserted into the power supply receptacle on the back of the printer before connecting or disconnecting the com- munications cables.
This printer complies with FCC “Rules and Regula- tions,” Part 15, for Class B Equipment, using fully shielded six-foot data cables. Use of longer cables or unshielded cables may increase radiated emissions above the Class B limits.
The required cable (IEEE 1284-compliant is recommended) must have a standard 36-pin parallel connector on one end, which is plugged into the parallel port located on the back of the printer. The other end of the parallel interface cable connects to the printer connector at the host computer.
For pinout information, refer to page 57.
Data cables must be of fully shielded construction and fitted with metal or metalized connector shells. Shielded cables and connectors are required to prevent radiation and reception of electrical noise.
Keep data cables as short as possible (6’ [1.83 m] recommended).
Do not tightly bundle the data cables with power cords.
Do not tie the data cables to power wire conduits.

When using the parallel port, typically there is no setup is required once the cable is plugged in. If you should encounter any problems, consult the user’s guide that came with your computer.
Print width may be set by way of the five-flash sequence in “Feed Button Modes” (see page52) or refer to the Print Width (^PW) command (consult your ZPL II Programming Guide).
The relative darkness setting is controlled by either the six-flash sequence in “Feed Button Modes” (see page 52) or the Set Darkness (~SD) ZPL II command (follow the instructions in the ZPL II Programming Guide).
Print quality is affected by print speed and the media you are using. Only by experimenting will you find the optimal mix for your application.
If you find that the print speed needs to be adjusted, refer to the Print Rate (^PR) command in the ZPL II Programming Guide.

This section helps you get the most from your printer.
You must use programming to control many of the printer’s functions. A few examples:
For detailed information about creating labels using ZPL II, refer to the ZPL II Programming Guide or visit our web site at www.zebra.com
To improve print quality, changing both print speed and density may be required to achieve the desired results. Your application’s printer driver provides control of the speed and heat (density).
The print head becomes hot while printing. To protect from damaging the print head and risk of personal injury, avoid touching the print head. Use only the cleaning pen to perform maintenance.
The discharge of electrostatic energy that accumulates on the surface of the human body or other surfaces can damage or destroy the print head or electronic components used in this device. You must observe static-safe procedures when working with the print head or the electronic components under the top cover.
You must use the correct media for the type of printing you require. When printing without a ribbon, you must use direct thermal media. When using ribbon, you must use thermal transfer media. The printer’s ribbon sensor detects motion of the supply spindle.

If labels or ribbon run out while printing, leave the printer power on while reloading (data loss results if you turn off the printer). After you load a new label or ribbon roll, the printer flashes double-green until you press the Feed button to restart .
Always use high quality, approved labels, tags and ribbons. If adhesive backed labels are used that don’t lay flat on the backing liner, the exposed edges may stick to the label guides and rollers inside the printer, causing the label to peel off from the liner and jam the printer. Permanent damage to the print head may result if a non-approved ribbon is used as it may be wound incorrectly for the printer or contain chemicals corrosive to the print head. Approved supplies can be ordered from your dealer.
If ribbon runs out in the middle of a print job, the indicator lights orange and the printer waits for you to add a fresh roll.
To remove used transfer ribbon, perform the following steps.
When reinstalling a partially used supply roll, tape the cut end onto the empty take-up roll.


The optional dispenser allows you to print in “peel-mode” where the label backing follows a different path and the labels are presented one at a time for subsequent placement.
^XA ^MMP ^XZ ^XA ^JUS ^XZ to the printer. Refer to your ZPL II Programmer’s Manual.
During the print job, the printer will peel off the backing and present a single label. Take the label from the printer so it will print the next label.


Printing on fan-fold media requires you to set both the media hangers and the media guides in position.

The Zebra R402 Smart Label Printer and Encoder serves as dynamic tool for both printing and programming smart labels, tickets and tags. Smart labels are usually made from two components, media and a RFID (radio frequency identification) transponder. The media will usually be comprised of synthetic- or paper-based material that can be printed upon using direct thermal or thermal transfer printing techniques. The media is typically made from the same materials and adhesives standard a non-RFID barcode printer would use. The second component of smart label is the transponder, sometimes known as the RFID tag. The transponder is usually comprised of an antenna coil that is bonded to an integrated circuit (IC) chip. The IC contains the RF drivers, coders, decoders and memory. At a minimum, RFID tags have memory that can be read, while the vast majority also have memory that can be programmed by the user as well.

The communication between the RFID tag and R402 printer is established when the transponder lines up with the printer’s antenna. Note that transponder position, prior to encode/decode, is critical. The optimal transponder position varies with antenna coil size and type of RFID IC used. It is important to use media and tags that have been specifically designed for use in the R402. Failure to do so may result in the inability to read or program the embedded RFID tags.
Printing and programming of smart labels in handled through the use of Zebra's printer programming language, ZPL. The printer segments the received ZPL's RFID and non-RFID related commands. The R402 will execute the RFID commands first, followed by the others (like the printing commands for barcodes or human readable text). Each transponder has blocks of addressable memory that are written to and read from through ZPL commands. Many transponders also contain a pre-programmed unique ID/serial number. The ZPL commands also provide for exception handling, such as setting the number of read/write retries before declaring the transponder defective. If an RFID tag is declared defective (fails to program correctly or cannot be detected) the printer ejects it and prints the word "void" across the entire label. This process will continue for two more RFID tags using the same data and format, assuming the problems persist. After the third tag is ejected the printer removes the customer format from the print queue, and proceeds with the next format (if one exists in the buffer).

Texas Instruments transponders are high frequency (13.56MHz) RFID devices. Each transponder has 256 bits of memory. Data is segmented into 4 byte (32 bit) blocks that are uniquely addressable, for a total of 8 blocks. Each memory block is lockable using the write protect function during the writing process.
Texas Instruments Tag-it™ Blocks Block # Description Bytes 0 User Data
1 User Data 2 User Data 3 User Data 4 User Data 5 User Data 6 User Data 7 User Data
32 User

Philips I•Code transponders are high frequency (13.56MHz) RFID devices. Each transponder has 512 bits of memory. Data is segmented into 4 byte (32 bit) blocks that are uniquely addressable for a total of 16 blocks. Each memory block is lockable using the write protect function during the writing process. The first two blocks of data (block 0 and 1) are pre-programmed, non-changeable, and are used for storage of a unique 64 bit serial number. The next two blocks (blocks 2 and 3) are used for storage of configuration information; block 4 is used for family or application identification and blocks 5 to 15 are free for user application use.
If you are using these transponders for your own use, and don’t require universal special function or family codes, then you can program blocks 3 through 15.
Philips I•Code Blocks Block # Description Bytes 0 Serial Number (write protected) 1 Serial Number (write protected) 2 Write Protect Block (Caution*) 3 Special Function Block 8 Optional 4 Family Code 5 User Data
6 User Data 7 User Data 8 User Data 9 User Data 10 User Data 11 User Data 12 User Data 13 User Data 14 User Data 15 User Data
* The bits in block 2 determine the write access conditions for itself and each of the remaining blocks. You can leave blocks 2 through 15 open or you can write-protect them. Write-protected blocks (included block 2) can never be written to from the moment they are locked
40 User

Inside Technologies Picotag® transponders are high frequency (13.56MHz) RFID devices. Each transponder has 2048 bits of memory. Data is segmented into 8 byte (64 bit) blocks that are uniquely addressable for a total of 31 blocks. Blocks 6 to 12 are lockable using the write protect function during the writing process. The first block of data (block 0) is pre-programmed and is used for storage of a unique 64 bit serial number. The next two blocks (blocks 2 and 3) are used for storage of configuration information; blocks 3 to 31 are free for user application use.
Block Byte number within a block 0 1 2 3 4 5 6 7 0 Serial Number (64 bits)
1Fh E.A.
S. Fuses
2 Application Issuer Area 3 Application Area 4 5 6
7 8 9 10 11 12 13 Application Area ... 31
Block Write Lockable Application Area

ISO-15693 is an international standard for 13.56 MHz RFID devices. As this is a public standard, tags and integrated circuits may be produced by a wide variety of manufacturers. The current standard stipulates that manufacturers may configure memory in various ways ( up to 256 blocks comprising a block size up to 256 bits (32 bytes)). The standard also stipulates that a manufacturer may, or may not, use the recommend methods of reading and writing to the tag as stipulated in the standard. For these reasons, the R402 may not be compatible with every manufacturers ISO-15693 transponders. Contact your technical support representative for the latest list of supported ISO-15693 transponders.

The format for the ^WT instruction is: ^WTb,r,m,w,s
where
^WT = Write Tag command
b = Block Number
Default value: 0 Other values: 1 to n, where n is the maximum number of blocks for the tag
This is the starting block number. If the user sends more than a block of data it will overflow into the next block. If the user overflows the block and subsequent blocks cause errors (write protects, beyond range, etc.), the write will be aborted, but blocks already written will not revert to original contents. It’s up to the caller to ensure blocks aren’t accidentally overwritten.
Default value: 0 Other values: 1 to 10, number of retries
m = motion
Default value: 0 (Feed label after writing) Other value: 1 (No Feed after writing, other ZPL may cause a feed)
Default value: 0 (NOT write protected) Other value: 1 (Write protect)
s = Special mode
Reserved

The format for the ^RT instruction is: ^RT#,b,n,f,r,m,s
where
^RT = Read Tag command
# = Number to be assigned to the Field
Default value: 0 Other Values: 1 to 9999
b = Starting Block Number
Default value: 0 Other values: 1 to n, where n is the maximum number of blocks for the tag
Default value: 1 Other values: 2 to n, where n is maximum number of blocks minus starting block number. In other words, if the tag has 8 blocks (starting with block 0) and you’re starting with block 6, n can be 2. This would give you block 6 and block 7 information.
Default value: 0 ASCII Other values: 1 Hexadecimal
r = Retries
Default value: 0 Other values: 1 to 10, number of retries
m = motion
Default value: 0 (Feed label after writing) Other value: 1 (No Feed after writing, other ZPL may cause a feed)
Default value: 0 Other values: 1 to 255, to specify more detailed mode control.

^FO20,120^A0N,60^FN1^FS
^FO20,100^A0N,20^FN2^FS
^RT1,0,7,3,0,5,0,0^FS
^RT2,0,2,2,0,5,0,0^FS
^XZ
The first ^RT command automatically detects the tag type, starting at block 7, reads three blocks of data in ASCII format. It will retry the command 5 times if necessary. A “void” label will be generated if the read is unsuccessful after ‘r’ retries. The data read will go into the ^FN1 location of the recalled format.
The second ^RT command automatically detects the tag type, string at block 2, reads two blocks of data in ASCII format. It retries up to 5 times. The data read will go into the ^FN2 location of the recalled format.
The data can be sent back to the host via the ^HV command.

The format for the ^RS instruction is: ^RSt,#
where
t = tag type
Default value: 0 –NONE (No tags available) Other values:
1- Auto detect (automatically determine the tag type, by querying the tag) 2- Texas Instruments Tag-it™ tags 3- Philips I•Code tags 4- Inside Technologies Picotag® 2K 5- ISO 15693 tag*
Set to 0 (zero) to not move the media. Default value: Label length minus eight dot rows
Use caution when using this function in combination with ^RI (reading the unique ID number) or ^RT (reading tag data). Problems can occur if the data read from the tag is going to be printed on the label. Any data read from the transponder must be positioned to be printed above the read/write position. Failure to do this will prevent read data from being printed on the label, ticket or tag.
* ISO-15693 is an international standard for 13.56 MHz RFID devices. As this is a public standard, tags and integrated circuits may be produced by a wide variety of manufacturers. The current standard stipulates that manufacturers may configure memory in various ways ( up to 256 blocks comprising a block size up to 256 bits (32 bytes)). The standard also stipulates that a manufacturer may, or may not, use the recommend methods of reading and writing to the tag as stipulated in the standard. For these reasons, the R402 may not be compatible with every manufacturers ISO-15693 transponders. Contact your technical support representative for the latest list of supported ISO-15693 transponders.

The format for the ^RI instruction is: ^RIn
where
n = field number to store the unique ID
The unique ID will be read from the tag and available to print or return to the host computer.
The example below reads the unique ID/serial number from a tag, and prints it on a label:
^FO100,100^A0N, 60^FN0^FS
^RI0^FS
^FD ^FS
^XZ

TM is Zebra Technologies Corporation’s Zebra Programming Language II label design language. ZPL II lets you create a wide variety of labels from the simple to the very complex, including text, bar codes, and graphics.
This section is not intended as an introduction to ZPL II. If you are a new ZPL II user, order a copy of the ZPL II Programming Guide (part# 46530L) or go to the internet address http://support.zebra.com and select the Documentation Button to download the guide.
From the DOS command window, use the “COPY” command to send a file to the Zebra printer. For example, if your file name is format1.zpl then type, “COPY FORMAT 1.ZPL XXXX”, where “XXXX” is the port to which your Zebra printer is connected, for example, “LPT1.”

Line # Type this label format Resulting printout
5. ^RT0,6,2^FS
6. ^RT1,6,2,1
7. ^XZ
Line 1 Indicates start of label format. Line 2 Writes the data “Zebra” to block 6 for the tag (one byte will
spill into block 7, since we have 4 bytes/block. Line 3 Print field number ‘0’ at location 100,100.^FN0 is replaced
by what we read on line #5. Line 4 Print field number ‘1’ at location 100,200. ^FN1 is replaced
by what we read on line #6. Line 5 Read Tag into field number 0, starting at block 6, lasting for 2
blocks in ASCII format (default). Line 6 Read Tag into field number 1, starting at block 6, lasting for 2
blocks in hexadecimal format. Line 7 End of label format.



Cleaning
Use only the cleaning agents indicated. Zebra Technologies Corporation will not be responsible for damage caused by any other cleaning materials used on this printer.
After allowing the print head to cool for approximately one minute, use 70% isopropyl alcohol on a cotton swab to clean the print elements from end to end (the print elements are located in the thin gray line on the print head). NOTE: You do not have to turn off the printer to do this.
If print quality has not improved after performing this procedure, try cleaning the print head with Save-a-Print Head cleaning film. This specially coated material removes contamination buildup without damaging the print head. Call your authorized reseller for more information.
After every five rolls of
Manually rotate the platen roller. Clean it thoroughly with 70% isopropyl alcohol and a cotton swab or lint-free cloth.
Peel bar Clean it thoroughly with 70% isopropyl alcohol and a cotton swab.
As needed Tear bar Clean it thoroughly with 70% isopropyl alcohol and a cotton swab.
Interior Brush or air blow
No lubricating agents of any kind should be used on this printer! Some commercially available lubricants, if used, will damage the finish and the mechanical parts inside the printer.

1 Latch Assembly 105910-052
2 Feed Switch/Sensor Assy (set of 3) 105910-128
3 Upper Cover Support (set of 3) 105910-066
4 Print Head Assy - 4” TLP Print Head Cable Assy.
5 Head Up Sensor 105910-129
6 Gap/Blackline Sensor PCBA (set of 3) 105910-054
7 Platen Kit (standard set of 3) 105910-055
8 Front Bezel (standard set of 10) Front Bezel, Dispenser (single)
10 Rubber Foot Kit (set of 24) 105910-007
11 Main Control PCBA (RFID) 105910-133
12 Bottom Frame Assy 105910-130
13 Upper Cover Assy 105910-131
14 Ribbon Out Sensor (set of 3) 105910-134
15 Ribbon Carriage w/o printhead 105910-132
Motor (set of 2) Power Supply, 100V-240V Power Cord, U.S. 120V IEC320C13 (set of 5) PCBA, RFID Reader PCBA, Antenna, Type 2 Ribbon Core, 4” (set of 50) Accessory, Media Adapter Plates
105910-051 105950-043 105950-014 105903-135 105950-136 105903-053 810059-001
Manuals User’s Manual, R402 ZPL II Programmer’s Manual
105910-053 105910-065 · 105910-057 105910-022 · Not Shown



In the event you need to replace the print head, make sure your work area is prepared by protecting against static discharge. Your work area must be static-safe and include a properly grounded conductive cushioned mat to hold the printer a conductive wrist strap for yourself.
Before following the steps in this procedure, open the printer by pulling the release latches forward then lifting the top cover. Remove any ribbon from the carriage.

Assembly
The new print head comes with the clip and ground screw attached.
Reload media and ribbon. Plug in the power cord, turn on the printer and run an automatic or manual calibration to ensure proper function.



Status LED Condition and Color
For a Resolution, Refer to number:
Solid Green On 2
Flashing Yellow Stopped 3
Flashing Green Normal Operation 4
Flashing Red Stopped 5
Double Flashing Green Paused 6
Solid Yellow Various 7
Alternately Flashing Green and Red Needs Service 8
Printer · Status · Off Off 1

There is a shortage of memory.
The print head is open.

The print head is over temperature.

No print on the label.
The printed image does not look right.
There are long tracks of missing print (blank vertical lines) on several labels.
The ribbon sensor settings did not print.

The printing does not start at the top of the label, or misprinting of one to three labels.
A label format was sent to, but not recognized by, the printer.

VOID messages are printed across media.
Nothing is printed.
Call a service technician if you have been unsuccessful in getting your expected print out and data.

Manual calibration is recommended whenever you are using pre-printed labels (or label backing) or if the printer will not correctly auto calibrate.
function. To return to auto calibration, default the printer (see the four-flash sequence in “Feed Button Modes” on page 52).


To print out a listing of the printer’s current configuration, refer to the one-flash sequence in “Feed Button Modes” on page 52.
Recalibrate the printer if it starts to display unusual symptoms, such as skipping labels. See “Auto Calibration” on page 14.
Zebr a Technol ogi es ZTC R402- 200dpi
+10 DARKNESS +000 TEAR OFF TEAR OFF PRI NT MODE NON- CONTI NUOUS MEDI A TYPE WEB SENSOR TYPE THERMAL- TRANS. PRI NT METHOD 104 0/ 8 MM PRI NT WI DTH 1233 LABEL LENGTH 22. 0I N 557MM MAXI MUM LENGTH 38400 BAUD 8 BI TS DATA BI TS NONE PARI TY XON/ XOFF HOST HANDSHAKE NONE PROTOCOL 000 NETWORK I D NORMAL MODE COMMUNI CATI ONS 7EH CONTROL PREFI X 5EH FORMAT PREFI X 2CH DELI MI TER CHAR ZPL I I ZPL MODE FEED MEDI A POWER UP FEED HEAD CLOSE DEFAULT BACKFEED +020 LABEL TOP +0000 LEFT POSI TI ON 029 WEB S. 068 MEDI A S. 050 RI BBON S. 050 MARK S. 001 MARK MED S. CS MODES ENABLED . . MODES DI SABLED 832 8/ MM FULL RESOLUTI ON SP. 814. B
FI RMWARE I N THI S PRI NTER I S COPYRI GHTED

Sometimes, resetting the printer to the factory defaults solves some of the problems. Follow the four-flash sequence instructions in “Feed Button Modes” on page 52.
If there is a problem transferring data between the computer and printer, try putting the printer in the communications diagnostics mode. The printer will print the ASCII characters and their respective hexadecimal values (a sample is shown below) for any data received from the host computer. To find out how, refer to the power off mode procedure in “Feed Button Modes” on page 52.


Power Off Mode (Communications Diagnostics Mode)
With the printer power off, press and hold the feed button while you turn on the power. The printer prints out a listing of its current configuration (see Figure 22). After printing the label, the printer will automatically enter a diagnostic mode in which the printer prints out a literal representation (see Figure 23) of all data subsequently received. To exit the diagnostic mode and resume printing, turn off and then turn on the printer.
With the printer power on and top cover closed, press and hold the feed button for several seconds. The green status LED will flash a number of times in sequence. The explanation at the right (Action) shows what happens when you release the key after the specific number of flashes.
* A configuration label prints.
* ** The media sensor calibrates and a media sensor profile prints (see “Manual Calibration” on page 49).
To reset the communication parameters. Press and release the feed button while the LED rapidly flashes yellow and green.
For autobaud synchronization: Send a ZPL II format to the printer while the LED rapidly flashes yellow and green. When the printer and host are synchronized, the LED changes to solid green. NOTE: No labels will print during autobaud synchronization.
* ** *** ****
Resets the factory defaults, auto calibrates, and saves settings into memory.
* ** *** **** *****
The print width calibrates. While the status LED alternately flashes green and yellow, a series of stacking rectangles print on the label. When the rectangle prints to the outer edges of the label, press and release the feed button. The label width and current communication parameters will be saved into memory.
* ** *** **** ***** ******
The print darkness calibrates. A series of nine samples print, starting with the lightest and ending with the darkest image. When the desired print darkness is achieved, press and release the feed button. The print darkness will be saved into memory.
If the feed button remains pressed after a 7-flash sequence, the printer will ignore the button when it is released.
Power On Modes · Flash Sequence Action · * ** ***

All specifications are subject to change without notice.
Size 7.8 inches wide / 6.8 inches tall / 9.4 inches long (depth) 200 mm wide / 173 mm tall / 240 mm long (depth)
Weight 3.6 pounds / 1.6 kilograms
Operating temp. 40 to 104 degrees Fahrenheit / 5 to 40 degrees Celsius
Operating humidity 10 to 90 percent non-condensing
Storage temp. -40 to 140 degrees Fahrenheit / -40 to 60 degrees Celsius
Storage humidity 5 to 90 percent non-condensing
Electrical Autoranging external power supply Input: 100-240VAC; 50-60 Hz Output: 20VDC; 2.5A
Print Density 203 dots per inch / 8 dots per millimeter
Print Speed 2 inches / 51 millimeters per second 3 inches / 76 millimeters per second 4 inches / 102 millimeters per second
Print Width 1.0 to 4.09 inches / 25.4 to 104 millimeters
Print Length 0.005 to 22 inches / 0.125 to 559 millimeters with standard memory
FLASH Memory (user available)
DRAM Memory (user available)
Registration Tolerance

Width 1 to 4.25 inches / 25.4 to 108 millimeters) 1 to 2.25 inches / 25.4 to 57 millimeters (tag stock)
Length 0.5 to 22 inches / 13 to 559 millimeters with standard memory
Gap 0.08 to 0.16 inch (2.0 to 4.0 millimeters) 0.118 inch / 3.0 millimeters recommended
Thickness 0.003 to 0.007 inch / 0.08 to 0.18 millimeter
Roll Size Maximum outer diameter: 5 inches (127 millimeters Inner Core diameters: 1 or 1.5 inches (25.4 or 38 millimeters) Optional media hangers available for larger inner core diameters
Requirements ✔User Zebra-brand direct thermal or thermal transfer media
that is outside wound. Media may be reflective (black mark) sensing or transmissive sensing, die-cut, notched, or continuous) ✔For die-cut labels, use only full auto dies. ✔Notched media must have a 0.5 inch (13 mm) wide by 0.094
inch (2.5 mm) long cutout located in the center of the roll. ✔The reflective media black marks must be located in the
center of the roll. Mark width 0.5 inch (13 mm) centered and perpendicular to the edge of the media; mark length 0.094 inch (2.4 mm) parallel to the bottom edge of the media.
✔Phillips I•Code ✔Texas Instruments Tag-It™ ✔Inside Technologies PicoTag® ✔ISO-15693
Always thoroughly test your desired media for your specific application before buying in large quantities.
Length 2,900 inches / 74 meter capacity; provides 1:1 media roll to ribbon ratios
Width At least as wide as media
Requirements User Zebra-brand ribbon that is outside wound.
Transponder Requirements · Setup Ink-side out

Fonts ✔CG Triumvirate Bold Condensed scalable smooth (0) ✔Zebra fonts A-H, GS, P-V ✔IBM Code Page 850 international Symbols
1D Bar Codes ✔Codabar (supports ratios of
✔Industrial 2 of 5 ✔Standard 2 of 5 ✔Interleaved 2 of 5 (supports
2:1 to 3:1) ✔Code 11 ✔Code 128/USD 8 (supports
ratios of 2:1 to 3:1, Modulus 10 Check Digit) ✔LOGMARS ✔MSI ✔Plessey ✔POSTNET ✔UPC-E ✔UPC-EAN Extensions
serialization in all subsets and UCC Case Codes) ✔Code 39 (supports ratios of
2:1 to 3:1) ✔Code 93 ✔EAN 8/JAN 8 ✔EAN 13/JAN 13 ✔EAN 14/UPC-A
2D Bar Codes ✔Codeblock ✔Code 49 ✔Data Matrix ✔MaxiCode
✔MicroPDG417 ✔PDF 417 ✔QRcode
Rotation Angles 0°, 90°, 180° and 270°
✔Downloadable graphics, scalable and
bitmap fonts, and label formats
✔Programmable quantity with print and
✔Object copying between memory areas
(RAM and internal FLASH)
✔Communicates in printable ASCII
✔Code Page 850 character set
✔Adjustable print cache
✔Controlled via mainframe,
mini-computer, PC, portable data terminal
✔Automatic virtual input buffer
✔In-spec OCR-A and OCR-B
✔Automatic memory allocation
✔Mirror image printing
✔Status message to host upon request
✔Four-position field rotation
0°, 90°, 180° and 270°

The Thermal Printer Model R402, manufactured by Zebra Technologies Corporation, complies with the applicable requirements:
EN300-683, IECS-003, EN61000-3-2, EN61000-3-3.
✔Adjustable core diameter media holders
✔Dispenser for “peel-off mode”

Pin No. Description
2-9 Data Bits 1-8
12 PError/ACK Dat Req.
14 NAuto Fd/Host Busy
18 +5 V @ 0.75 A Fused
32 NFault/nData Avail.
35 +5 V throught 1.8 K Ohms Resistor
The maximum current available through the interface port is not to exceed a total of 0.75 amps.










Pagine di riferimento in questo manuale: produttore, supporto e download.
Il significato dei codici di errore mostrati sul display e come cancellarli.
| Codice | Significato | Risolvi | |
|---|---|---|---|
| V2 | 2. 6. 98. C | p.24 |
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.