Manuale d’uso / di manutenzione del prodotto CA43-CV7 or CV13 del fabbricante BevLes
Vai alla pagina of 32
Convection Heated Holding Cabinet s 1 OPERA TION & MAINTENANCE MANUAL Phone: +1 Fax: +1 (214) 565-0976 T oll Free: +1 (800) 441-1601 Website: www .BevLes.com E-mail: sales@BevLes.com (214) 421-7366 BevLes 729 Third Avenue Dallas, TX 75226 Innovative Foodservice Equipment Custom Designed for Performance, Service and V alue.
W ARRANTY GETTING ST ARTED OPERA TION CARE OF YOUR UNIT TROUBLESHOOTING MAINTENANCE REPLACEMENT P ARTS WIRING DIAGRAMS 3 4 INTRODUCTION 4 MODELS 4 UNP ACKING 4 SETTING-UP 5 CLEANING .
4/02 BEVLES COMP ANY LIMITED W ARRANTY 729 Third A venue * Dallas, TX 75226 Phone: +1 (214) 421-7366 Fax: +1 (214) 565-0976 1/05 1. W ARRANTY.
2. GETTING ST ARTED 2-1 INTRODUCTION **NOTE: "NOTE" "W ARNING” 2-2 MODELS 2-3 UNP ACKING **NOTE: W ARNING: NOTE: BEVLES Heated Holding Cabinets are quality built equipment designed to hold prep ared foods at a safe temperature (no less than 140°), with or without humidity .
2-4 SETTING-UP **W ARNING: Locate your holding cabinet in an area where the doors can be opened without impeding your operation and where loading and unloading product will be easy .
Figure 5 10. Clean all pieces thoroughly and carefully with soapy water and soft cloths. Neveruse steelwoolor causticcleaning compounds. Avoid splashing water or any other liquid into the heating module to prevent possible damage to electrical components.
4. CARE OF YOUR UNIT As with any piece of quality equipment, your BEVLES Heated Holding Cabinet requires regular care and maintenance. The most vit al procedure is the regular and thorough cleaning of the entire unit.
4. If you are unable to locate the problem in the table or if the solutions listed don't work, please call the BEVLES manufacturing facilities for assistance at (800) 441-1601. Y ou will need to provide the factory personnel with the following information: 1.
Figure 8 Figure 9 Figure 10 6. MAINTENANCE **CAUTION: All maintenance on BEVLES Heating Holding Cabinets should be performed by trained personnel using only quality BEVLES part s. 6-1a. Removing the top mounted heating module. Required: No tools required 1.
5. Feed the wires of the replacement indicator lamp module through the opening and snap the new indicator lamp module into place. 6. Reconnect wiring with each of the two new wires going to a different wire nut (it doesn't matter how you match the new module wires).
Figure 19 Figure 16 Figure 17 Figure 18 6.1f. Replacing the thermometer . **NOTE: 6-1g. Replacing the power cord for a CA70 unit. Required: Crescent or standard 3/4" wrench 1.
6-1h. Replacing the power cord for a CA43. Required: Medium (6”) phillips screwdriver , Medium (6") flathead screwdriver , Wiring markers (color or number codes), Electrical tape , Wiring diagram for CA43(see step 10) 1. Remove the back p anel of the module by removing the five phillips head screws and gently lif ting out the back panel.
Figure 24 Figure 25 Figure 26 Diagram 3 Figure 27 Figure 28 Figure 29 Figure 30 6-1i. Replacing the thermost at for a CA70. Required: Small flathead screwdriver , Medium (6") flathead screwdriver , Medium (6") phillips screwdriver , Wiring markers (color or number codes), Electrical tape, Wiring diagram for thermost at (see step 9) 1.
Figure 31 Figure 32 7. Pull the copper thermostat probe and tubing from the fan blower motor assembly area through the opening to the front cover (it may be necessary to feed the probe, into the bottom of the assembly area under the fan blower to achieve the correct angle).
Diagram 5 Figure 39 Figure 38 Figure 37 Figure 36 Figure 35 8. Remove the two screws and nuts securing the clips that att ach the copper thermostat probe to the motor bracket. Use a medium flathead screwdriver . (Fig. 38) 9. Pull copper probe and tubing from fan blower motor area through the opening to the front panel.
Figure 43 Figure 44 Figure 45 Figure 42 Figure 41 Figure 40 6-1k. Replacing the fan blower motor assembly . **NOTE: **NOTE: **NOTE: Required: Medium (6") flathead screwdriver , Medium (6”) phillips screwdriver , Crescent or standard wrench, Wiring markers (color or number codes), Electrical tape 1.
12. For CA70 unit s, secure fan blower motor bracket with the four phillips screws. Reatt ach thermostat probe clips with two flathead screws. DO NOT kink or bend the copper probe or tubing. 13. For CA43 units, reatt ach thermostat probe clips with two flathead screws.
6-1m. Replacing the High-temperature safety thermost at. 6-1 n. Replacing the top mounted heating module seal (gasket). **NOTE: 6.1o. Replacing the fan blower cooling fan for CA43 unit s. Required: Medium (6”) flathead screwdriver , Medium (6") phillips screwdriver , Crescent wrench 1.
7. REPLACEMENT P ARTS Use only BEVLES replacement part s in repairing your unit. This assures you of continued high quality performance. T o determine the parts you need: 1. Use the drawings found in section 7-5 and refer to the parts list in section 7-6 to determine the BEVLES part numbers you need.
7-5a. Heating Module for CA70 Models 1 1A 1B 2 2A 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 22A 23 24 25 26 27 28 28A 29 30 31 32 33 34 34A Heating Module Heating Module, MP Heating Module, HW.
CA43 MODELS 7-5c. Heating Module for CA43 Models Drawing Reference Number Description 1 1A 1B 2 2A 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22A 23 24 25 26 27 28 28A 29 30 31 32 33 34 34A .
7-5a. EXPLODED VIEW - HEA TING MODULE FOR CA70 MODELS 28 28A 29 31 32 1 1A 1B 17 16 13 7 6 2 2A 8 5 12 9 11 3 4 14 10 27 18 15 33 34 34A 20 21 24 22 22A 25 23 26 30.
40 14A 24A 24 26 28 29 31 32 25A 35 39 38 1 1A 1B 37 22 21 17 33 19 20 23A 23 3A 3 36 34 18 14 15A 15 16 4 4A 12 13 10 25 30 8 9 5 5A 6 7 11 27 2A 2 7-5b.
7-5c. EXPLODED VIEW - HEA TING MODULE FOR CA43 MODELS 28A 29 28 34 34A 31 32 30 1 1A 16 19 13 7 6 2 2A 8 5 3 4 9 10 11 12 14 20 37 37A 38 21 33 24 22 22A 25 23 26 1B 15 27 18 17.
7-5d. EXPLODED VIEW - CABINET ASSEMBL Y FOR CA43 MODELS 1 1A 1B 19 20 22 21 17 33 6 6 7 3 3A 34 36 35 37 10 12 13 24A 24 23 23A 9 11 26 27 25 25A 30 31 32 28 29 8 2 2A 5 5A.
7-6 P ARTS LIST CA43-CV7 CV7HW CV13 CV13HW CVMP6 CVMP7 7-6i. Heating Module 7-6j. Heating Module Control Panel 7-6k. Heating Module Blower Motor 7-6I. Heating Module Heating Element 7-6m. Cabinet 7-6n. Cabinet Interior 7-6o. Cabinet Front Door 7-6p. Cabinet Rear Door Model Number List Number CA70-CV16 CV16HW CV32 CV32HW CVMP12 CVMP15 7-6a.
1 1A 1B 2 2A 3 3A 4 4A 5 5A 6 7 8 9 10 11 12 13 14 14A 15 15A 16 17 18 19 20 21 22 23 23A 24 24A 25 25A 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 20024 20128 20136 20028 20030 20032 20108 20036 201.
1 1A 1B 2 2A 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22A 23 24 25 26 27 28 28A 29 30 31 32 33 34 34A 35 36 37 37A 38 20068 20132 20140 41060 41 152 70169 70104 82128 50468 70288 821 16 82.
1 1A 1B 2 2A 3 3A 5 5A 6 7 8 9 10 11 12 13 17 19 20 21 22 23 23A 24 24A 25 25A 26 27 28 29 30 31 32 33 34 35 36 37 20068 20132 20140 20072 20074 20076 20124 20080 20082 50132 50140 50736 70073 50392 5.
Notes: IMPORT ANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For W ARRANTY SER VICE and/or P ARTS, this information is required.
Notes:.
Phone: +1 Fax: +1 (214) 565-0976 T oll Free: +1 (800) 441-1601 Website: www .BevLes.com E-mail: sales@BevLes.com (214) 421-7366 BevLes 729 Third Avenue Dallas, TX 75226 Innovative Foodservice Equipment Custom Designed for Performance, Service and V alue.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il BevLes CA43-CV7 or CV13 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del BevLes CA43-CV7 or CV13 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso BevLes CA43-CV7 or CV13 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul BevLes CA43-CV7 or CV13 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il BevLes CA43-CV7 or CV13, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del BevLes CA43-CV7 or CV13.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il BevLes CA43-CV7 or CV13. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo BevLes CA43-CV7 or CV13 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.