EN Reference Manual.
ACD1 Reference Manual 2 Contents Introduction............................................. 3 About the documentation ................................. 3 Supported amplifiers ......................................... 3 Setup ...........................
ACD1 Reference Manual 3 Intr oduction About the documentation This document explains mainly the operation and specifications of the A CD1 amplifier control de vice itself. When using the A CD1, y ou will also need to consult various manuals other than this document.
ACD1 Reference Manual 4 Introduction T erms This section explains terminology specific to the A CD1. ■ Amp Editor This is computer application software. W ith this software, you can use your computer to monitor and control the A CD1 and the amplifiers connected to the A CD1.
ACD1 Reference Manual 5 Contr ols and Connectors q Display This sho ws information about the scene, the A CD1 itself, or the connected amplifiers. This will light red when an abnormal- ity (a W ARNING or higher alert) occurs. This will also blink blue and white when the Identify operation is performed in Amp Editor.
ACD1 Reference Manual 6 Controls and Connectors y Ground scre w The A C power cord is a 3-wire type. If the A C outlet used is earthed (grounded), this de vice will be properly earthed as well. Also, grounding the scre w sometimes reduces hum and interference noise.
ACD1 Reference Manual 7 Panel operations By pressing b uttons on the panel you can monitor or contr ol various parameters of the A CD1 itself or of the con- nected amplifiers. The f ollowing parameters can be monitor ed/controlled. Category Sub category Operation performed 1.
ACD1 Reference Manual 8 Panel operations The main roles of each b utton are as follo ws. As an example, we’ll explain how to stor e the scene of an amplifier connected to the A CD1.
ACD1 Reference Manual 9 Panel operations 5. Use the [ ▲ INC/YES] / [ ▼ DEC/NO] b uttons to select the ID of the amplifier f or which you want to stor e settings. 6. Press the [NEXT] b utton to move to the scene number . 7. Use the [ ▲ INC/YES] / [ ▼ DEC/NO] b uttons to select the scene number that y ou want to store.
ACD1 Reference Manual 10 Panel operations Here’ s how to r ecall or store scenes for a specified amplifier . ■ Recalling a scene (“1. Scene” ➝ “Recall”) Recalls a scene for the specified amplifier . • If you select “ALL ” as the Amp ID , the scene name will not be displayed.
ACD1 Reference Manual 11 Panel operations These settings allow y ou to control an amplifier connected to the A CD1. ■ Po wer on/standb y (“2. Amp Contr ol” ➝ “Standby”) Switches the po wer of the specified amplifier between On and Standby .
ACD1 Reference Manual 12 Panel operations This indicates the output lev el of the amp connected to the A CD1. ■ Amplifier output (“3. Output Monitor”) Displays the output le vel for each channel of the specified amplifier .
ACD1 Reference Manual 13 Panel operations ■ Identify (“4. Device Setup” ➝ “Identify”) Blinks the “Identify” icon of the corresponding A CD1 in Amp Editor. Here y ou can make overall settings f or the A CD1 and view various types of inf ormation.
ACD1 Reference Manual 14 Panel operations ■ LCD bac klight (“5. Utility” ➝ “LCD Bac klight”) This specifies the lit status of the A CD1’ s LCD backlight. ■ Restricting panel operations (“5. Utility” ➝ “P anel Operation”) Here you can turns panel operation lock on/of f.
ACD1 Reference Manual 15 Panel operations ■ Enabling scene recall operations via EMG commands (“5. Utility” ➝ “EMG Scene Setup”) Specifies whether the EMG scene will be recalled when the EMG (Emer - gency) signal is recei ved. The follo wing three types of EMG signal can be recei ved.
ACD1 Reference Manual 16 Panel operations ■ GPI IN calibration (“5. Utility” ➝ “GPI Calibration”) Calibrates the detected range of the [GPI IN] connector input v oltage. Here y ou can make network settings f or the A CD1. ■ IP Address Mode setting (“6.
ACD1 Reference Manual 17 Panel operations ■ Po rt settings f or an external contr oller (“6. Network Setup” ➝ “IP Ctrl P or t #”) Here you can specify the port number that will be used to control the A CD1 from an external de vice such as an AMX or Crestron unit.
ACD1 Reference Manual 18 Connector wiring This section explains how to wir e the [GPI] and [F A UL T OUTPUT] connectors located on the A CD1’s r ear panel. Be sure to use the supplied Eur oblock connector . If you lose the connector , contact your Y amaha dealer .
ACD1 Reference Manual 19 Connector wiring Connect GPI (General Purpose Interface) de vices (e.g., contr ol- lers) to the rear panel [GPI] connector . Y ou can use GPI to send or r eceive contr ol signals to or from an external de vice. The A CD1 provides 4-port input and 4-port output.
ACD1 Reference Manual 20 Connector wiring Y ou can connect a lamp etc. to the r ear panel [F A UL T OUTPUT] connector to indicate that an abnormality has occurred. The [F A UL T OUTPUT] connector consists of NO (Normally Open), C (Common), and NC (Normally Closed).
ACD1 Reference Manual 21 Appendix Messages that may appear in the A CD1’ s display and the appropriate responses ar e listed below . F or more about alert messages, refer to the Amp Editor o wner’ s manual. The A CD1 allows the f ollowing single-byte characters to be displayed and input.
ACD1 Reference Manual 22 Appendix Tr oubleshooting Symptom P ossible causes Response All scene data sav ed in the ACD1 has disap- peared The power w as tur ned off while the ACD1’ s data was being sa ved Once again synchronize the unit with Amp Editor to transmit the settings from Amp Editor.
ACD1 Reference Manual 23 Appendix *1 Suppor ted models XP7000, XP5000, XP3500, XP2500, XP1000, XM4180, XM4080, XH200 Guaranteed cable length: 50m *2 Suppor ted models T5n, T4n, T3n, PC9501N, PC6501N, .
ACD1 Reference Manual 24 Appendix Unit : mm * Specifications and descr iptions in this owner’ s manual are for inf or mation purposes only . Y amaha Cor p . reserves the right to change or modify products or specifications at any time without prior notice.
U .R.G., Pro Audio & Digital Musical Instrument Division, Y amaha Corporation © 2009 Y amaha Corporation 911-PO-C0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Yamaha ACD1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Yamaha ACD1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Yamaha ACD1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Yamaha ACD1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Yamaha ACD1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Yamaha ACD1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Yamaha ACD1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Yamaha ACD1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.