Manuale d’uso / di manutenzione del prodotto 2550 del fabbricante Vermont Casting
Vai alla pagina of 40
0956 Encore Co v er 2/01 Homeowner ’ s Installation and Operating Manual SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAIN- T AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS.
2 Encore W oodbur ning Stove 2000956 Congratulations on your choice of a V ermont Castings Encore. With this purchase you have made a commitment to make the hearth a place of warmth, beauty , and comfort in your home. At CFM Corporation, we share that joy and appreciation for the hearth.
3 Encore W oodbur ning Stove 2000956 Specifications 2" (50mm) 25 " (640mm) T op exit flue collar height 27" (685mm) 25 " (660mm) 18 " (470mm) 7 .
4 Encore W oodbur ning Stove 2000956 SAFETY NOTICE: IF YOUR ENCORE IS NOT PROP- ERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC- TIONS AND INST ALLA TION INSPECTION REQUIRE- MENTS IN YOUR AREA.
5 Encore W oodbur ning Stove 2000956 What Kind of Chimney to Use Y ou must connect the Encore to a code-approved masonry chimney with a flue liner , to a relined masonry chimney that meets local code.
6 Encore W oodbur ning Stove 2000956 Chimney Connector Guidelines A chimney connector is the double-wall or single-wall pipe that connects the stove to the chimney . The chim- ney itself is the masonry or prefabricated structure that encloses the flue.
7 Encore W oodbur ning Stove 2000956 ST492 Defiant freestanding installation 1 1/00 Chimney Elbow Slip Pipe Standard Connector Oval to Round Adapter Flue Collar Thimble Flue Liner Flue ST492 Fig. 6 An exploded view of the chimney connection in a free- standing masonry installation.
8 Encore W oodbur ning Stove 2000956 • The fireplace damper must be sealed to prevent room air from escaping up the flue. However , it must be possible to re-open the damper to inspect or clean the chimney . * Check These Clear- ances ST244 Plymouth fplc over mantel 12/99 * * Chimney Connector Shields Mantel Seal this off ST244 Fig.
9 Encore W oodbur ning Stove 2000956 D E F I A N T ST493 Brick pass thru 1 1/00 W all Stud Chimney Connector 12” Noncombustible Material Floor Pro- tection ST493 Fig.
10 Encore W oodbur ning Stove 2000956 Floor Protection for Fireplace Installations Do not assume that your fireplace hearth is completely noncombustible. Many fireplace hearths do not meet the “completely noncombustible” requirement because the brick or concrete in front of the fireplace opening is supported by heavy wood framing.
1 1 Encore W oodbur ning Stove 2000956 In general, the greatest clearance is required when you place a stove and its connector with no heat shields near a wall with no heat shield.
12 Encore W oodbur ning Stove 2000956 Chimney Connector Heat Shields Chimney Connector Heat Shields should be used whenever the rear heat shield is used, or in any other situation when it is necessary to protect nearby com- bustibles from the heat of the connector .
13 Encore W oodbur ning Stove 2000956 Alcove Installations Because of their restricted air flow and heat reten- tion characteristics, alcove installations have specific construction requirements and special clearances. No rear stove or chimney connector heat shields are used in alcove installations.
14 Encore W oodbur ning Stove 2000956 24” (610 mm) 8” (203 mm) 12” (305 mm) 4” (102 mm) 2 12” (305 mm) * (A) 24” (B) 31” (C) 24” (D) 8” (E) 15” (F) 8” (610 mm) (787 mm) (610 mm) .
15 Encore W oodbur ning Stove 2000956 Stove Installed Parallel to W all Stove Installed Parallel to W all Stove in Corner Stove in Corner Unprotected Surfaces Protected Surfaces T op Exit , No Heat Sh.
16 Encore W oodbur ning Stove 2000956 W all Shield Requirements for Common Installations E E C B A B D ST629a Encore wall shield AA 02/01 E E A = 30” (762 mm) B = 44” (1 1 18 mm) C = 36” (914 mm) D = 66” (1676 mm) E = 1” (25 mm) ST629a Fig. 23 Parallel installation, vertical chimney connector , with stove, connector and wall shields.
17 Encore W oodbur ning Stove 2000956 Distance from the Center of the Flue Collar to the W all in T op-Exit Installations The information on this page is helpful in planning stove placement for top-exiting installations, particularly those in- stallations with chimneys that pass through the ceiling.
18 Encore W oodbur ning Stove 2000956 Set Up Y our Stove Cast iron stoves are heavy , and it will take two to four people to move your Encore into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel. Install the handle on the griddle.
19 Encore W oodbur ning Stove 2000956 ST540 Assembly handle 1 1/00 ST540 Fig. 32 Assemble the front door handle. Operation The Encore Controls T wo controls regulate the performance of the Encore: a primary air control supplies oxygen for the fire, and a damper directs air flow within the stove to activate and deactivate the catalytic combustor .
20 Encore W oodbur ning Stove 2000956 The damper is closed when the handle points forward . Smoke from the fire is directed through the catalytic combustion system where it can be further burned for greater efficiency , before passing up the chimney .
21 Encore W oodbur ning Stove 2000956 Infrared Reflective Glass Panels for Clear Fire Viewing The inner surfaces of the infrared reflective glass panels are kept at a higher temperature than the outer surface. This design, along with a preheated ‘airwash,’ makes clear fire viewing possible at most levels of operation.
22 Encore W oodbur ning Stove 2000956 In some newer homes that are well-insulated and weather-tight, poor draft may result from insufficient air in the house. In such instances, an open window near the stove on the windward side of the house will provide the fresh air needed.
23 Encore W oodbur ning Stove 2000956 Conditioning Y our Stove Cast iron is extremely strong, but it can be broken with a sharp blow from a hammer or from the thermal shock of rapid and extreme temperature change. The cast plates expand and contract with changes in temperature.
24 Encore W oodbur ning Stove 2000956 5. Close the damper when the griddle temperature reaches 450°F (230°C). 6. Adjust the air control for your desired heat output. NOTE: Stove installations vary , and the operating guidance given here is only a starting point.
25 Encore W oodbur ning Stove 2000956 • Remove the ash pan, making sure to keep it level. • T o keep the cover from sliding off and to keep ash from falling on the floor , do not tilt the ash pan for- ward. If the stove is in operation, close the ash door while disposing of the ash.
26 Encore W oodbur ning Stove 2000956 Flue Sizing The inside size of a chimney for an ‘airtight’ stove should match the size of the stove’s flue outlet.
27 Encore W oodbur ning Stove 2000956 Back-puffing Back-puffing results when the fire produces volatile gases faster than the chimney draft pulls them out of the firebox. The gases back up in the firebox till they’re dense enough and hot enough to ignite.
28 Encore W oodbur ning Stove 2000956 Removing the Glass The left door is slightly different from the right in that one of its retainer clips is located under the door mani- fold.
29 Encore W oodbur ning Stove 2000956 2. Turn the pressure screw approximately one half turn clockwise. 3. Tighten the lock nut. Keep the pressure screw from turning as you tighten the nut.
30 Encore W oodbur ning Stove 2000956 missing, it should be replaced. Call your local V er- mont Castings’ Authorized Dealer for a replacement element. While the catalytic element is removed, check the condition of the secondary air probe. Use an inspection mirror to locate the probe within the combustion cham- ber .
31 Encore W oodbur ning Stove 2000956 8. If the element is in good condition and clean, re-in- stall it in the stove and replace the refractory access cover . 9. Replace the fireback, install the two wedges, and replace the cast iron hood. 10. Clean the chimney and chimney connector .
32 Encore W oodbur ning Stove 2000956 8. Clean any excess cement from around the chan- nel, then let the cement that holds the new gasket dry thoroughly . Adjust the Door If Necessary The stove’s door(s) may need adjustment after you have regasketed it.
33 Encore W oodbur ning Stove 2000956 Appendix: Catalytic Combustor In any chemical reaction, including the combustion process, there are certain conditions which must be met before the reaction can take place.
34 Encore W oodbur ning Stove 2000956 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
35 Encore W oodbur ning Stove 2000956 1. Included in #5008649 upper fireback assembly . 2. Not interchangeable, due to a heat-reflective coating on the room side of the panels. 3. Included in #0004345 ceramic handle assembly . Encore W oodburning Stove Model 2550 (continued) Item Description Part Number Item Description Part Number 15.
36 Encore W oodbur ning Stove 2000956 Shell Enamel Parts - Encore Enamel Color T op Left Side Right Side Front Ashlip Single Leg Classic 1308618 1308623 1308619 1308635 1307406 1307427 Biscuit 3000300.
37 Encore W oodbur ning Stove 2000956.
38 Encore W oodbur ning Stove 2000956.
39 Encore W oodbur ning Stove 2000956 W arranty Limited 3 Y ear W arranty CFM Corporation warrants that this woodburning stove will be free of defects in material and workmanship for a period of three.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting 2550 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting 2550 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting 2550 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting 2550 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting 2550, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting 2550.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting 2550. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting 2550 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.