Manuale d’uso / di manutenzione del prodotto SF 50 del fabbricante Aarrow Fires
Vai alla pagina of 34
INSTALLATION & OPERATING INSTRUCTIONS The Stratford Multifuel Sf & Si Stoves Stratford Sf 50 Convector PLEASE RETAIN THESE INSTRUCT IONS FOR FUTURE REFERENCE.
2 Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Stratford Multifuel to ensure ultimate performance and years of trouble free enjoyment. Every detail on the fire has been carefully engineered and designed which is why we are so confident in the reliability of our product.
3 The Stratford Sf & Si Installation and Operating Instructions Contents Operating Instructions 1 Introductio n - The Principle of the Fire 5 2 Checklist 6 A - Stratford Sf B - Stratford Si 3 F i .
4 WARNING To All Solid Fuel Users PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE "CALCO", "PETROCOKE " OR "WONDERCO" MUST NOT BE BURNED IN THIS APPLIANCE TO USE THIS FUEL W.
5 Operating Instructions For The Stratford Multifuel Sf & Si. 1. INTRODUCTION - THE PRINCIPLE OF THE FIRE Your Aarrow Fire is built to the highest standard of craftsmansh ip using the best materials and the most modern equipment available.
6 2. CHECK LIST Inside the ap pliance you s hould find the followi ng. Stratford Sf 30 Stratford Sf 50 Stratford Sf 70 Stratford Sf 90 Stratford Si 40 Stratford Si 60 Conv.
7 3. FIRE BED Grate The grates in the Stratford Sf & Si Multifuel units co mpri se a series of reciprocating cast iron bars seated on a pivoted "comb".
8 4. REFRACTORY LINING FOR S f CONVECTOR MODELS ONLY Warning: Refracto ry linings a re very fr agile, han dle with ex treme care . Stratford Sf Multifuel Convectors are lined with reflective panels, cons isting of a combination of rectangular linings, whic h sit on the rear ledge, a nd side lini ngs which sit on the l andings.
9 • Remove front fuel retaine r bars. • Set the four li nings on t he side ledges on either side of the fireb ox. See Fig 5. • Set the three 197mm x 230mm rectangular linings on the u pper surface of the grate bar channel at the rear of the firebox.
10 6. THE AIR SYSTEM Flue Outlet/Hot Plate only for Sf The flue outlet is packed together with the firebrick lin ing and multi-purpose tool, insid e the appliance.
11 Disassemble Air Wash (see fig. 7) The air wash may be disassembled for cleaning or adj ustment to achieve this the following pro cedure should be followed when the fire is cold and unlit. • Support Air Wash cover with one ha nd • Move cover up by smartly tapping the bo ttom with a hammer.
12 Ash pit door Figure 8 7. GLASS/TRIM A gilt trim fitted around firedoor glass comes as standard . It clips on to the small lugs at the top and botto m of the aperture in the cast iron firedoor, as a "spring fit". When fitted, the trim locks the glass retaining clips in position.
13 8. DOOR ADJUSTMENTS The catch can be adjusted by sharply tapping the catch on the inside of the door as shown in Fig 10. Once the appliance has been under fi re for a period of t ime the fire door m ay appear to have m oved out of alignment with relation to th e door aperture or catch on the door in terlock mechanism.
14 9. SPARE PARTS LIST A - Stratford Sf Description Item Part No Sf30 Sf50 Sf70 Sf90 Ashpit Door, complete with Han dle & Seal 1 AFS045 AFS046 AFS049 AFS049 Ashpit Door Handle 2 AFS 041 AFS041 AFS.
15 B -Stratford Si Description Item Part No Si40 Si60 Ashpit Door, complete with Ha ndle & Seal 1 AFS045 AFS046 Ashpit Door Handle 2 AFS041 AFS041 Decorative Trim (Door Surround) Gold B l a c k 3 .
16 10. ACCESSORIES Stands Elegant stands are availabl e for the Stratfo rd Sf only . These increase the height of the appliance and rear fl ue outlet by approximately 125 mm (6'').
17 TECHNICAL DATA THE STRATFORD Sf RANGE Stratford Sf 30 Stratford Sf 50 Stratford Sf 70 Stratford Sf 90 Conv. Boiler Conv. Boiler Conv. Boiler Conv. Boiler Room Heater only Min/Max output (kw) 2 - 8 .
18 Recommended fuels are as fellows: The Hetas Ltd, "Three Tick" appliance approval only covers th e use of the following fuels in this ap pliance; Phurnacite, Phur nacite Plus , Centurion, Maxibrite, Extracite, Pureheat, Blazebrite, Taybrite, Sunb rite (Doubles/Singl es), Anthracit e and Welsh Dry Steam C oal (Large/ Small Nuts ).
19 Lighting the fire Solid fuel burning • On multifuel fires with variable grate setting facility set the grate to the "coal" burn ing position. • Ensure that ash pan is in positio n and the fire door closed. • Set the air wash to one quarter open position.
20 In the morning • Open air control fully un til the embers begin to glow brightly. • Lightly de -ash. • Place smaller pieces of fuel on the fire up to the top of the fuel retainer ba rs. • When the fi re is well establ ished de-ash and em pty the ash pan.
21 For Stratford Si • Engage the operating tool on the comb extentio n. • Move up and down vigorously the riddling lever (Ash will fall into the ash pan beneath the grate).
22 Aarrow fires are designed so that the flue can be swept t hrough the appliance once the throat plate has been removed. Access for cleaning shoul d also be inco rp orated in t he chimney (i.e. a soot do or). Door Glass The door glass should remai n clear during norm al daytim e burning.
23 Installation Instructions For The Stratford Sf & Si Multifuel 17. GENERAL During installat ion ensure that adequat e precautions ar e taken to avoid unnecessar y risk to yourself or any householder.
24 21. AIR FOR COMBUSTION There must always be a permanent m eans of provi ding air f or combus tion into t he room i n which the fi re is installed. A permanent vent with a total free area of at leas.
25 When a flue lining is fitted (to stainl ess steel or pum ice chimney system s) it should be supported independe ntly to the appliance, i.e. with clip s, brackets, flue lintels, etc. NOT simply resting on t op of the appl iance. It sh ould be possible to remove the fire for m ajor m aintenance work.
26 B - The Stratford Si Take out the removable items from the appliance (see se cti on 18 Handling ). Plug bo iler connections, which are not require d. Checking the thermostat. The thermostat is fitted within the ou ter casing on the left hand sid e of the unit's front .
27 MINIMUM 6" dia. SOOT DOOR ASBESTOS ROPE PACKING MINIMUM 150mm (6") BRICK UP APERTURE FILL VOID REAR FLUE OUTLET ALL INSTALLATIONS MUST CONFORM TO THE BUILDING REGULATIONS Reinstate brickw ork around pipes using li me mortar, and ma ke good.
28 register plate TOP FLUE OUTLET INSULATED CHIMNEY SYSTEM Soot door Horizontal 150mm (6") between support brackets 2.4 metres (8' 0") maximum or Maximum 50mm (2") gap to wall 600m.
29 TYPICAL INSTALLATIONS FOR INTEGRAL BOILER Central Heating and Domestic Hot Water, System Using Three Boiler Tappings. TYPICAL INSTALLATIONS FOR INTEGRAL BOILER Central Heating and Domestic Hot Water, System Using Four Boiler Tappings. Note: Diagrammatic representatio n only.
30 26. WATER CONNECTIONS Heating systems The size of the heating system, which can be run, will depend on the output rating of the appliance. It will b e necessary to work out heat loss calculations for the system envisage d in order to establ ish the kW/hr r ating.
31 A check list (Pre-lighting Checks) app ears in the Operating In structions, but in additio n to this the installer should: • Operate the heating system and set the pump head.
32 28. GUARANTEE Once again we would l ike to thank y ou very much for buying a St ratford fire. When you buy an Aarrow fi re, you are not only buyi ng a first cl ass appliance - you are buying a commitm ent from us to l ook after y ou and y our appliance for as lo ng as you wa nt.
33 30. SERVICE RECORD Date of Visit Company Name of Engineer Telephone Work Carried Out Parts Replaced Stamp or Signature Should you have any q uestions about your fi re that are not covered in this m.
34 Manufactured by July 2001.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Aarrow Fires SF 50 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Aarrow Fires SF 50 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Aarrow Fires SF 50 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Aarrow Fires SF 50 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Aarrow Fires SF 50, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Aarrow Fires SF 50.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Aarrow Fires SF 50. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Aarrow Fires SF 50 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.