Arada Ltd North Mills Industrial Estate, Bridport, Dorset, United Kingdom DT6 3BE T el (+44) 01308 427234 Fax (+44) 01308 423441 www .arada.uk.com Sherborne GSL Conventional Flue Gas S tove Installati.
INST ALLA TION Safety Notices 3 General Information 3-4 Contents List & Part Identification 5 Important Notices 6 Statutory Requirements 6 Certification 6 T echnical Data 7 Gas Fire Dimensions 7 I.
References in this manual to British Standards and Statutory Regulations and Requirements apply only to the United Kingdom. For Ireland the rules in force must be used. Before installation, check that the local distribution conditions, nature of the gas, pressure and the adjustment of the appliance are compatible.
5. S tove location See installation instructions on page 7. 6. Packed details For packed weight see packaging labels. 7.Unpacking note When the stove is unpacked ensure no damage occurs if placed on the carpet as it can leave inden- tation marks. For contents list see page 5.
ALL TYPES Main Box Aarrow Sherborne GSL CF 5 INST ALLA TION INSTRUCTIONS • • Packed Inside S tove Coal Set (NG & LPG) or Log Set (NG Only) or • • Log Set (LPG Only) • GLASS FRAME ASSEMBL.
IMPOR T ANT NOTICES A qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current Building Regulations.
Aarrow Sherborne GSL CF 7 INST ALLA TION INSTRUCTIONS TECHNICAL DA T A Natural Gas Gas Category I 2H NOx Class Unclassified T able 1 Fig. 3 Efficiency Class CLASS 2 INST ALLING THE STOVE A CORGI quali.
PREP ARA TION OF THE STOVE Prior to starting the installation and after removing the packaging, check that all the parts have been supplied to the contents list on page 5. Carry out the following:- S tep 1 Remove outer casing (disengage locking levers see page 25, steps 1a /b, 2, 3, 4, and 5).
SHELF CLEARANCES Combustible shelf clearances The minimum height from the extreme top surface of the stove to the underside of a shelf or other projection made of wood or any other combustible material is shown on graph 1.
FLUE SYSTEM The stove must be connected to a suitable and efficient flue that provides a good updraught to safely take the products of combustion (fumes) from the stove outlet to the outside air . T o ensure a good updraught it is important that the flue gases are kept warm and that the flue size suits the stove.
FITTING THE FLUE SPIGOT AND BLANKING PLA TE Note: Blanking plate fitted to top flue outlet for packing The gas stove is designed so that the flue can be fitted to either the top or the rear of the appliance. Fit the flue spigot and blanking plate for either top or rear flue outlet in accordance with figure 5a or 5b (below).
12 Aarrow Sherborne GSL CF INST ALLA TION INSTRUCTIONS Fig. 6b Fig. 6a Fig. 6c. Y=See Graph 1.
CONNECTING THE GAS SUPPL Y Once the stove is in place it is then possible to connect the gas supply . The gas supply point is located centrally at the rear (as show in fig.7) and should be connected in accordance with the follow- ing requirements. Fig.
FITTING AND ARRANGING THE COALS (Both NG & LPG versions) Ensure the appliance is cold Safety Notice - Please see SAFETY NOTICES ref. Coal / Log sets page 3. W arning: The coals and the coal matrix are fragile ensure they are handled carefully . Ensure location is correct.
Plan V iew Of Coal Set Layout. Note - Ensure that the pilot light is visible through the slot in the front right base matrix and that the pilot flame is not impinged. FITTING AND ARRANGING THE LOGS (NG ONL Y) Ensure the appliance is cold Safety Notice - Please see SAFETY NOTICES ref.
upper corner of the curved left hand log. See Fig. 12b. Note, the top resting position of the central log is angled to the left. 6) Place 2x smaller twigs as shown in Fig. 12b. Note, the bottom of the twigs rest between the stove body and burner . T ake care with the right hand twig to avoid impinging upon the pilot assembly .
3) Place the curved log to the left hand side of the firebox, rest the top of this log onto the top of the Y shaped open end of the rear log. T ake the straight log and position this to the right hand side of the firebox, again rest the rear of this log onto the rear Y shaped log, opposite end to the curved log.
NOTE: If the optional remote contr ol system has been ordered with the stove and is not fitted please proceed. FOR A MANUAL ST OVE (WITHOUT REMOTE CONTROL) PROCEED TO P AGE 22.
ASSEMBLE MOTOR 1) Remove the front cover from the valve. This is done by unscrewing the small pozi screw , located by knob B. Unclip the right hand side of the cover located to the side of knob A. See Fig. 16a & b. 2) Remove the cover and dispose of the spacer tube fitted with the screw .
ASSEMBLE RECEIVER Important The remote system is intended for use with original Aarrow parts only . 1) Carefully push the multi block connector on to the connection within the reciever unit as shown in Fig 17a.
HANDSET 1) Insert the battery (9v) into Remote control. Slide back the battery compartment cover , insert and connect a suitable battery and replace the cover . 2) The remote is now ready to use. In the event of battery failure the flame height can still be adjusted man- ually using the knob B on the valve.
COMMISSIONING THE ST OVE Refit the glass/glass frame assembly . Refit the outer body and secure with the locking levers. If horizontal flue is used fit the canopy cover plate. (See page 25 step 1a.) If top flue is used locate the infill plate (See page 25 step 1b).
Advise the end user 1. That there will be an odour from the stove when the stove is first lit and is non-toxic. It is advised that the stove is initially run with the room well ventilated to disperse the fumes. 2. How the valve controls operate and how to light the pilot.
24 Aarrow Sherborne GSL CF INST ALLA TION INSTRUCTIONS CHECKLIST Hearths, Fir eplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory , and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002.
Aarrow Sherborne GSL CF 25 SER VICING REPLACEMENT OF THE GLASS IMPOR T ANT When refitting the glass frame ensur e the origi- nal screws ar e used. Longer screws may foul the coal / log set placement. Ensure the appliance is cold. S tep 1a For rear flue appliance remove canopy cover plate.
26 Aarrow Sherborne GSL CF SER VICING S tep 7 Clear inside of stove of any debris. S tep 8 T o re-assemble reverse this procedure. See initial note on page 25. Note: When relocating the body and canopy assembly ensure the front location tab is engaged in the chassis.
ANNUAL SER VICE THIS GAS APPLIANCE MUST BE SERVICED EVERY TWEL VE MONTHS BY A QUALIFIED GAS ENGINEER. See "SAFETY NOTICES" ref coal set page 3. Ensure the appliance is cold. S tep 1 Isolate the gas supply from the stove. S tep 2 Remove the outer body of the stove.
28 Aarrow Sherborne GSL CF SER VICING Is the gas supply turned on? Does the pilot ignite? Ye s Does the pilot stay alight? Ye s Does the main burner light? Ye s No Is their air in the system? Ye s Is the main injector blocked? Ye s Clean and replace as necessary Is the supply pressure correct? No Is the thermocouple o.
Should you have any questions about your Sherborne GSL Gas Stove that is not covered in this manual please contact your Aarrow stove retailer . Please keep all repair receipts safely . Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
30 Aarrow Sherborne GSL CF ADDITIONAL NOTES.
USER INSTRUCTIONS Aarrow Sherborne GSL CF 31.
LIGHTING & CONTROLLING THE FIRE Under no circumstances must the stove be operated if the glass is cracked or broken. It is recommended that if the property is occupied the pilot be left on permanently . This will keep the stove and its components, including the ceramic coal / log set in a warmer state and assist the light- ing of the burner .
S tep 3. T o turn the stove and the pilot off completely , turn control knob “A” to the small flame setting, (pilot frame) depress and turn to off position, then release (See Fig.
NOTE: ONL Y FOR STOVES WITH REMOTE CONTROL SYSTEM TEMPERA TURE DISPLA Y REMOTE CONTROL When the pilot has been lit, the remote transmitter can be used to control the flame height or to turn the main burner on or off.
THERMOST A T AND TIMER REMOTE CONTROL TRANSMITTER FUNCTIONS Set the display (from *C/24 h to *F/12 h and vice versa) • After connecting the battery or by simultaneously pressing AUT O and TIMER, the display flashes you are in set mode.
Manual Mode (Man in Display) for Manual Flame Height Adjustment • Press ( A ) to turn on the fire (main burner) or to increase flame height. • Press ( B ) to decrease the flame or to turn down to pilot. • T o incrementally increase or decrease the flame height lightly tap either the ( A ) or ( B ) button.
Slide back the battery compartment cover , insert 4 suitable batteries and replace the cover If the batteries lose power , the flame height can be adjusted by manually turning knob B (see page 32) NOTE Please note the placement of the remote control (temperature sensor) is important to assure proper tempera- ture regulation.
IMPOR T ANT NOTICES A qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current Building Regulations.
SHELF CLEARANCES Combustible shelf clearances The minimum height from the extreme top surface of the stove to the underside of a shelf or other projection made of wood or any other combustible material is shown on graph 1.
40 Aarrow Sherborne GSL CF SP ARE P AR TS 1. Coal set (Complete) AFGS1 115 AFGS1 121 AFGS1 123 AFGS1 124 AFGS1087 AFGS1 125 AFGS1 126 3. Log set - LPG (Complete) 4. Injector NG - BRA Y 82/400 5. Injector LPG - BRA Y 82/160 6. Pilot assembly - NG 7. Pilot assembly - LPG 8.
Aarrow Sherborne GSL CF 41 SP ARE P AR TS 10. Control V alve AFGS1089 AFGS1 128 AFGS1093 AFS047 AFGS1 118 AFGS1095 AFGS1096 1 1. Fire door set (with handles) 12. Glass Frame Assembly 13. Hinge Kit & W ith Fixings- 14. Dummy Fuel Retainer 15. Instruction Manual 16.
42 Aarrow Sherborne GSL CF SP ARE P AR TS 17. T op Flue Cover Plate AFGS1098 Part Description V isual Aid (not to scale) Part Number AFGS1 120 18. T op Flue Infill Piece AFGS1 119 19. V alve Cover AFGS1 129 20. Flue Spigot Complete W ith Rope Gasket AFGS010 21.
Aarrow Sherborne GSL CF 43 OPTIONS & ACCESSORIES Remote Control - A remote control system can be retro-fitted to your Sherborne GSL stove. This system allows convenient control of the stove, room temperature regulation and the advantage, to be programmable to enable switching on / off by a timer function*.
44 Aarrow Sherborne GSL CF GUARANTEE Y our Sherborne GSL stove carries a Liftime* guarantee against defects to the stove body . All other components carry a guarantee period of One year from the date of purchase . This does not apply to items which would be subject to fair wear or tear .
Aarrow Sherborne GSL CF 45 ADDITIONAL NOTES.
Model.................................. Serial No............................. I’ve checked it and it’ s O.K. Assembled by ........................
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Aarrow Fires Gas Stove è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Aarrow Fires Gas Stove - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Aarrow Fires Gas Stove imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Aarrow Fires Gas Stove ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Aarrow Fires Gas Stove, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Aarrow Fires Gas Stove.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Aarrow Fires Gas Stove. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Aarrow Fires Gas Stove insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.