Manuale d’uso / di manutenzione del prodotto 0968 del fabbricante Vermont Casting
Vai alla pagina of 38
1 Vermont Castings Defiant Homeowner ’ s Installation and Operating Manual For use in the United States and Canada SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS.
2 Vermont Castings Defiant This manual describes the installation, operation, and maintenance of the V ermont Castings Defiant Model 1910 catalytic-equipped wood burning heater . This heater meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold on or after July 1, 1990.
3 Vermont Castings Defiant T able of Contents Specifications .................................... 4 Installation ......................................... 5 Clearance Charts ............................ 12 Assembly ....................................
4 Vermont Castings Defiant Specifications Defiant, Model 1910 Range of heat output .......... 10,600 to 44,400 Btu’s/hr .* Maximum heat output ........................ 55,000 Btu’s/hr .** Area heated ............................ Up to 2,400 Square feet Fuel Size/type .
5 Vermont Castings Defiant Installation SAFETY NOTICE: IF YOUR DEFIANT IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
6 Vermont Castings Defiant What Kind of Chimney to Use You must connect the Defiant to a code-approved masonry chimney with a flue liner, to a relined masonry chimney that meets local codes, or to a p.
7 Vermont Castings Defiant Accessories to help make the connection between stainless steel chimney liners and your Defiant are available through your local dealer . Chimney Connector Guidelines A chimney connector is the single-wall pipe that connects the stove to the chimney.
8 Vermont Castings Defiant Securing the Single-wall Connector to a Masonry Chimney Both freestanding masonry chimneys and fireplace masonry chimneys may be used for your installation.
9 Vermont Castings Defiant If the chimney connector in your installation enters the chimney above a fireplace, follow all the guidelines mentioned above for freestanding installations.
10 Vermont Castings Defiant NOTE: Do not vent your Defiant into a factory-built (zero-clearance) fireplace. These appliances and their chimneys are specifically designed as a unit for use as fireplaces. It may void the listing or be hazardous to adapt them for any other use.
11 Vermont Castings Defiant Keep the Stove a Safe Distance from Surrounding Materials Both a stove and its chimney connector radiate heat in all directions when operating, and nearby combustible materials can overheat dangerously if they are too close to the heat source.
12 Vermont Castings Defiant Defiant Clearance Chart for use with either a 6” or 8” flue collar/chimney connection Stove Clearance Stove Installed Parallel to Wall Unprotected Surfaces Protected Su.
13 Vermont Castings Defiant T op Exit Installations, no heat shields Defiant Clearance Diagrams for use with either a 6” or 8” flue collar/chimney connection Stove Installed Parallel to Wall Stove.
14 Vermont Castings Defiant DE F I A NT 48" (1220mm) 48" (1220mm) 48" (1220mm) Fig. 13 Parallel installation with rear wall pass-through, two wall shields. Reduced clearances to both rear and side walls. W all shields may meet at corner if desired.
15 Vermont Castings Defiant Distance from the Center of the Flue Collar to the W all The information on this page is helpful in planning stove placement, particularly in those installations with chimneys that pass through the ceiling. However, this is not a clearance chart.
16 Vermont Castings Defiant Set Up Your Stove Cast iron stoves are heavy, and it will take two to four people to move your Defiant into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel. Install the handle on the griddle.
17 Vermont Castings Defiant Assemble the Removable Insert Handle The white removable insert handle opens and closes the front doors. Remove after each use, and store it in the handle holder behind the left front leg. Assemble the handle by passing the 3 ³⁄₈ " screw through the ceramic shaft and into the bright metal nub.
18 Vermont Castings Defiant A Damper Directs Air Flow Within the Stove The damper handle on the left side of the stove operates the damper to direct air flow within the stove. The damper is open when the handle points to the rear , enabling smoke to pass directly into the chimney .
19 Vermont Castings Defiant WARNING: FIREPLACE STOVES EQUIPPED WITH DOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE FIREPLACE STOVE OPENING, CREATING RISKS FROM BOTH FIRE AND SMOKE.
20 Vermont Castings Defiant Use the Air Control Settings that Work Best for You No single air control setting will fit every situation. Each installation will differ depending on the quality of the fuel, the amount of heat desired, and how long you wish the fire to burn; outdoor air temperature and pressure also affect draft.
21 Vermont Castings Defiant In general, the fire must be sufficiently well- established to ensure that catalytic activity is initiated. When first starting a fire, a medium- to high- firing rate must be maintained until the stove, catalyst, and fuel are all stabilized at the proper operating temperatures, and the chimney is warmed.
22 Vermont Castings Defiant 5. Close the damper when the griddle temperature reaches 450 ° F (230˚C). 6. Adjust the air control for your desired heat output. ST264 Fig. 28 Add larger pieces of wood as the fire begins to burn well. NOTE: Stove installations vary widely , and the operating guidance given here is only a starting point .
23 Vermont Castings Defiant likely to glow at its higher temperatures, which it reaches when the firebox is in its lower range - the catalyst is an afterburner , and the more waste fuel there is in the smoke, the hotter the catalyst gets. We strongly advise the use of a stove-top thermom- eter as a guide to stove performance.
24 Vermont Castings Defiant DRAFT MANAGEMENT A stove is part of a system, which includes the chimney, the operator, the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well.
25 Vermont Castings Defiant There should be no more than eight feet of single- wall stove pipe between the stove and a chimney; longer runs can cool the smoke enough to cause draft and creosote problems. With prefabricated chimney , bring it down to six to eight feet from the stove.
26 Vermont Castings Defiant Negative Pressure Good draft also depends on a supply of air to the stove; a chimney can’t pull in more air than is available to it.
27 Vermont Castings Defiant Keep Y our Stove Looking New and W orking Its Best Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep the painted cast iron of your Defiant looking new.
28 Vermont Castings Defiant Check the Operation of the Primary Air Shutter The primary air shutter is at the back of the ash drop and is visible from the back of the stove. (Fig. 33) The shutter must open and close freely when you move the thermostat lever.
29 Vermont Castings Defiant The Catalytic Element This wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation.
30 Vermont Castings Defiant Alignment Notches Left Wedge Brick Guide Brick Clip Bricks ST556 Fig. 37 Remove the bricks and the brick retainer . Right Wedge Lower Fireback ST557 Fig. 38 Remove the lower fireback. 3. Carefully remove the catalytic combustor ’s refractory access cover , then remove the combustor .
31 Vermont Castings Defiant 6. If the element is in good condition and clean, re- install it in the stove and replace the refractory access cover . 7. Replace the fireback, the five bricks and their clip, the left and right wedges, and the baffle.
32 Vermont Castings Defiant 7. Press the gasketed part firmly against its normal mating surface to seat the gasket evenly in its channel. Close and latch the door to do this, or tap other parts with the rubber mallet (or hammer/block of wood).
33 Vermont Castings Defiant Appendix: Catalytic Combustor In any chemical reaction, including the combustion process, there are certain conditions which must be met before the reaction can take place.
34 Vermont Castings Defiant Appendix: Chimney and Fireplace Hazards General - A. Improper chimney height. The top of the chimney must be at least 3 feet higher than the spot where it passes through or past the roof, or two feet higher than everything else within ten feet horizontally, whichever is higher.
35 Vermont Castings Defiant 85 13 29 1 2 3 6 4 8 16 26 17 18 5 14 46 47 49 64 66 7 28 34 36 37 40 41 48 27 11 30 31 33 84 10 67 42 44 57 58 43 66 52 85 35 65 59 61 73 81 80 83 74 76 45 70 71 54 56 79 .
36 Vermont Castings Defiant Item/Model Number Part Number Defiant (continued) 13. Left Griddle Quadrant 1301807 14. Right Griddle Quadrant 1301832 16. Griddle 1301641 17. Griddle Handle 1600657 18. Griddle Handle Spacer 1600070 19. Griddle Handle Bolt 1201308 20.
37 Vermont Castings Defiant W arranty Limited 3 Y ear W arranty The Vermont Castings Majestic Products Company warrants that this woodburning stove will be free of defects in material and workmanship .
38 Vermont Castings Defiant 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www .majesticproducts.com • www.vermontcastings.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vermont Casting 0968 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vermont Casting 0968 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vermont Casting 0968 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vermont Casting 0968 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vermont Casting 0968, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vermont Casting 0968.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vermont Casting 0968. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vermont Casting 0968 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.