UNITED ST A TES STOVE COMP ANY 227 INDUSTRIAL P ARK RO AD • P .O. BO X 151 • SOUTH PITTSBURG, TN. 37380 • (423)-837-2100 This is an unvented gas-fired heater . It uses air (o xygen) from the room in which it is installed. Provisions for adequate combus- tion and ventilation air must be provided.
SECTION P SECTION P SECTION P SECTION P SECTION P A A A A A GE GE GE GE GE IMPOR T ANT SAFETY INFORMA TION.......................................................3-4 PR ODUCT FEA TURES ...................................................................
IMPOR T ANT SAFETY INFORMA TION 3 INST INST INST INST INST ALLER: ALLER: ALLER: ALLER: ALLER: Please leav e these instr uctions with the owner . OWNER: OWNER: OWNER: OWNER: OWNER: Please retain these instructions for future reference.
IMPOR T ANT SAFETY INFORMA TION CONTINUED 13. Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 15. Any safety screen or guard removed for servicing, must be replaced prior to heater operation.
9947 SPECIFICA TIONS Natural Gas Natural Gas Natural Gas Natural Gas Natural Gas Manifold Pressure Setting: 4" w .c. Gas Inlet Pressure: Maximum 10-1/2" w .c. Minimum 5" w .c. Propane/LPG Propane/LPG Propane/LPG Propane/LPG Propane/LPG Manifold Pressure Setting: 10" w .
6 ITEMS REQ ITEMS REQ ITEMS REQ ITEMS REQ ITEMS REQ UIRED FOR INST UIRED FOR INST UIRED FOR INST UIRED FOR INST UIRED FOR INST ALLA ALLA ALLA ALLA ALLA TION TION TION TION TION Ensure that the followi.
The following formula can be used to determine the maximum heater rating per the definition of unconfined space: BTU/HR = (L1+L2) Ft x (W) Ft x (H) Ft x 1000 50 Consider two connecting rooms with an open area between, with the following dimensions:( See Fig.
8 If placing a custom mantel above the heater, you must meet minimum clearances between mantel shelf and the top of the heater. If your installation does not meet the below minimum clearances, you must: • Raise the mantel to an acceptable height, OR • Remove the mantel.
9 Connecting directly to an unregulated propane/LPG tank can cause an explosion. Connecting directly to an unregulated propane/LPG tank can cause an explosion. Connecting directly to an unregulated propane/LPG tank can cause an explosion. Connecting directly to an unregulated propane/LPG tank can cause an explosion.
The heater regulator controls the burner pressure which should be checked at the pressure test point located on the front of the main control and is accessible by removing the control panel on the right side of the heater. The pressure should be checked with the heater burning and the control set to high (HI).
LOG POSITIONING LOG POSITIONING LOG POSITIONING LOG POSITIONING LOG POSITIONING Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fibers.
Avoid any drafts that alter the burner flame patterns. Do not allow fans to blow directly into the heater. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.
1 . STOP! Read the safety information on the previous page. 2 . Set the thermostat to lowest setting. 2 . Turn off all electrical power and open the access door. 3 . Push in gas control (B) slightly and turn clock wise to "OFF". 5 . Push "ON / OFF" switch to "OFF" position.
Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. Remove front screen, (see page 11). Carefully lift screen from locating stubs and set aside during cleaning. Refer to instructions on page 11 for installation of screen.
In normal operation at full rate after 15 minutes the following flame appearance should be observed. FLAMES FLAMES FLAMES FLAMES FLAMES The flames behind log #1, and in between log #2, should be yellow with a blue base. (See Below, Figure 12) Figure 12.
HEA TER ASSEMBL Y 16.
KE Y P A R T NO . DESCRIPTION QTY . 1 24775 Pedestal 1 2 24776 P edestal T r im 1 3 24878 Pedestal Brace 1 4 69243 Firebox Bottom 1 5 24779 Firebox 1 6 69248 Firebo x Inner T op 1 7 24782 Firebo x Out.
BURNER AND LOG ASSEMBL Y 14 4 2 18 20 19 11 8 9 18 3 5 6 13 16 15 1 12 7 17 10.
KE Y P AR T NO . DESCRIPTION QTY . 1 24777 BURNER PLA TE 1 2 89920 BURNER 1 3 89921 "O .P . AMERICA" NA T . PILO T 1 • 89922 "O .P . AMERICA" L.
NOTE: All troubleshooting items are listed in order of operation. REMEDY REMEDY REMEDY REMEDY REMEDY POSSIBLE CAUSE POSSIBLE CAUSE POSSIBLE CAUSE POSSIBLE CAUSE POSSIBLE CAUSE When ignitor button is pressed, there is no spark at ODS/Pilot.
TROUBLE SHOOTING ODS/Pilot lights, but flame goes out When control knob is released. (continued from page 20) One or both burner do not light after ODS/pilot is lit. Burner backfires during combustion. Slight smoke or odor during initial operation. Logs appear to smoke after initial operation.
OPTIONAL EQUIPMENT REMOTE SKYTEC H SKYTECH 1001 ON OFF INDICATOR R E M O T E NO OFF SKYTECH 50 60 70 80 90 21 10 32 c 50 60 70 80 90 21 10 32 c MODEL: RCK60 REMOTE CONTROL KIT MODEL: WSK60 W ALL SWITC.
CONTROL WIRING TERMINALS ROCKER SWITCH THERMOPILE WIRING DIAGRAM FOR GENERATOR ASSEMBLY WIRING DIAGRAM FOR BLOWER ASSEMBLY 1/4" MALE INS. 1/4" FEMALE INS. 1/4"FEMALE INS. 1/4"FEMALE INS. 1/4"FEMALE INS. 1/4" MALE INS. 1/4" MALE INS.
ST ST ST ST ST AND AND AND AND AND ARD ARD ARD ARD ARD WIRING FR WIRING FR WIRING FR WIRING FR WIRING FR OM F OM F OM F OM F OM F A A A A A CT CT CT CT CT OR OR OR OR OR Y Y Y Y Y : : : : : WIRING OF .
WIRING WIRING WIRING WIRING WIRING WITH WITH WITH WITH WITH THE THE THE THE THE WTK60 - WTK60 - WTK60 - WTK60 - WTK60 - W W W W W ALL ALL ALL ALL ALL THERMOST THERMOST THERMOST THERMOST THERMOST A A A.
NOTES NOTES NOTES NOTES NOTES 26.
LIMITED LIMITED LIMITED LIMITED LIMITED W W W W W ARRANTY POLICY ARRANTY POLICY ARRANTY POLICY ARRANTY POLICY ARRANTY POLICY This vent-free gas heater is warrantied for a period of one year, logs for one year, and burners for One Year, from date of purchase against defects in material or workmanship.
OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL HO W T O ORDER REP AIR P AR TS OR "OPTIONS" UNITED ST UNITED ST UNITED ST UNITED ST UNITED ST A A A A A TES ST TES ST TES ST TES ST TES ST O O O O O VE COMP VE COMP VE COMP VE COMP VE COMP ANY ANY ANY ANY ANY 227 Industrial Park Rd.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il United States Stove 9947 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del United States Stove 9947 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso United States Stove 9947 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul United States Stove 9947 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il United States Stove 9947, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del United States Stove 9947.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il United States Stove 9947. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo United States Stove 9947 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.