SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE, LOW ENERGY AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.
DWG NO SIZE SHEET SCALE CAGE CODE PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: ENG'G FILE OF: DRAWN BY: REV 01 24 VAC MC-25 #1 PUSH PLATE D.
DWG NO SIZE SHEET SCALE CAGE CODE A PH: (412) 249-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: FILE OF: DRAWN BY: REV TITLE: PAIR OF DOORS WITH MC25, ELECTRIC.
PH: (412) 249-4100 FAX: (412) 249-4101 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: SHEET: SCALE: A REV: DRAWN BY: SIZE: CAGE CODE: DWG NO: FILE OF: B.
.
A FILE OF: DRAWN BY: 1 OF 1 NTS CAGE CODE: DWG NO: REV: SIZE: SHEET: SCALE: DATE: NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 FOR DRY CONTACTS.
SIZE: DRAWN BY: TITLE: MC-25 w/ SARGENT EL PANIC DEVICE & AUTOMATIC DOOR OPERATOR A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, APT. BUZZER RELAY/ FIRE ALARM A NOTES: 1) JUMPERS JP1,JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER AND BRIDGE RECTIFIER VO LT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE.
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVERS, SEPARATE POWER SUPPLY FOR MAGLOCK, NIGHT MODE RELAY A NOTES: 1) JUMPERS JP1 & JP2 ARE PLACED ON PINS 1,2 AND 4,5 F OR DRY CONTACTS. 2) TYPE OF RELAY WILL BE DETERMINED BY MAGLOCK VOLTAGE (12 OR 24 VOLT S).
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC STRIKE, AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMINED BY CURRENT DRAW OF ELECTRIC STRIKE.
DWG NO SIZE SHEET SCALE CAGE CODE PH: (412)782-4100 FAX: (412) 249-4101 B.E.A., Inc. 100 Enterprise Drive, Pittsburgh, PA 15275 DATE: NONE FILE OF: DRAWN BY: REV MC25 #2 TRANSFORMER KM 2000 DOOR CONTR.
SIZE: DRAWN BY: TITLE: MC-25 WITH 3 WIRE RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, ELECTRIC STRIKE, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #2. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
SIZE: DRAWN BY: TITLE: MC-25 WITH RECEIVER, MAGNETIC LOCK, PUSHPLATE AUTOMATIC DOOR APPLICATION A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT.
SIZE: DRAWN BY: TITLE: MC-25 WITH ELECTRIC PANIC, PUSHPLATE AUTOMATIC DOOR APPLICATION A 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.
SIZE: DRAWN BY: TITLE: 2 MC-25s WITH ELECTRIC STRIKE, SEQUENCING 2 DOOR PANELS A NOTES: 1) JUMPERS ARE PLACED ON J1 PINS 1&2, J 2 PINS 4&5 FOR DRY CONTACTS ON RELAY OUTPUT #1. 2) PUSH PLATE, MOTION SENSOR, CARD READER MUST BE DRY CONTACT. 3) TRANSFORMER VOLT/ AMPERE RATING IS DETERMIND BY CURRENT DRAW OF ELECTRIC STRIKE.
SIZE: DRAWN BY: B 100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL : www.be ase nso rs. com REV BY: KJG JDC SCALE: DATE: NONE 20 MARCH 2006 PART NO: SHEET 1 OF 1 80.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il BEA 80.0011.02 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del BEA 80.0011.02 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso BEA 80.0011.02 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul BEA 80.0011.02 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il BEA 80.0011.02, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del BEA 80.0011.02.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il BEA 80.0011.02. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo BEA 80.0011.02 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.