Manuale d’uso / di manutenzione del prodotto C-AL80(L) del fabbricante TOA Electronics
Vai alla pagina of 16
Instruction Manual ON OFF POWER ALARM INPUT UNIT C-AL80(L) C-AL80(H) Thank you for purchasing TOA's Alarm Input Unit. Please carefully follow the instructions in this manual in order to ensure long, trouble-free use of your Alarm Input Unit.
2 T ABLE OF CONTENTS 1. SAFETY PRECA UTIONS ................................................................................ 3 2. GENERAL DESCRIPTION ............................................................................. 4 3. HANDLING PRECA UTIONS .
3 1. SAFETY PRECA UTIONS • Before installation or use, be sure to carefully read all the instructions in this section in order to ensure long, trouble-free operation. • Be sure to follow all the precautionary instructions in this section, which contain important warnings regarding safety.
4 Indicates a potentially hazardous situation which could result in moderate or minor personal injury, and/or property damage if ignored or mishandled. CA UTION When Installing the Alarm Input Unit • Never insert nor remove the power supply plug with wet hands, as an electric shock may result.
5 1 2 3 4 Cov er The inside of the cov er ON OFF POWER ON OFF UNIT No. LEVEL REMOTE OFF ABBREVIA TION No.9001 REMOTE ALARM ABBREVIA TION No.1 REMOTE ON EDGE 1234 12 34 (1) Power Switch [ON/OFF ] Used to turn power on and off. (2) Power Indicator Lights when the Power switch is set to ON.
6 [Rear P anel] 5 6 7 8 9 10 11 ALARM/ / REMOTE IN CAMERA SELECT OUT ALARM / REMOTE OUT MASTER / SLA VE RS-232C OFF ON TERMINA TION (5) Power Inlet Connects to the supplied power supply cord. (6) Alarm/Remote Input Terminal [Alarm/Remote Input] Use the Mode Selection switch (4) to perform input function settings.
7 123 4 1 32 33 64 65 96 97 128 129 160 161 192 193 224 225 256 Master Unit's Switch Setting Master Unit 1 Slav e Unit 2 Slav e Unit 3 Slav e Unit 4 Slav e Unit 5 Slav e Unit 6 Slav e Unit 7 Slav e Unit 8 123 4 LEVEL REMO TE OFF ABBREVIA TION No.
8 3 REMO TE OFF REMO TE ON 4 LEVEL EDGE 5.3. Alarm/Remote Output Settings It cannot be used. Please fix to the "Remote OFF" (Factory-preset position: "Remote OFF") 5.4. Alarm Interval Settings Set the alarm time interval to "Edge" or "Level" with Model Selection switch 4.
9 12 3 4 G N D 56 7 8 G N D 91 0 1 1 1 2 G N D 13 14 15 16 G N D 17 18 19 20 G N D 21 22 23 24 G N D 25 26 27 28 G N D 29 30 31 32 G N D 6. USING THE ALARM/REMO TE FUNCTION 6.1. Alarm/Remote Input The Alarm/Remote input terminals on the rear panel are designed to be used for both alarm and remote inputs.
10 7. CONNECTION EXAMPLE 7.1. Connection to the C-RM500 Remote Controller Monitor C-RM500 Alarm Input Unit C-AL80 Alarm/Remote Input RS-232C Sensor Sensor 1 4 6 9 5,10 Sensor 1 4 6 9 5,10 Multi-Switch.
11 Unit Number Setting switch (3) Unit Number Setting switch (3) Unit Number Setting switch (3) Unit Number Setting switch (3) C-AL80 Alarm Input Unit Master Unit Slave Unit 1 Slave Unit 2 Slave Unit 7 123 4 Unit No. OFF ON 123 4 Unit No. OFF ON 123 4 Unit No.
12 123 4 123 4 123 4 123 4 123 4 123 4 123 4 123 4 Unit No. switch setting Master Unit Slave Unit 1 Slave Unit 2 Slave Unit 3 Slave Unit 4 Slave Unit 5 Slave Unit 6 Slave Unit 7 123 4 Unit Number ON OFF 8.
13 1 4 2 5 3 1 4 2 5 3 1 4 2 5 3 Master/Slave terminal Master/Slave terminal • Master/Slave Terminal Cable Type Use the supplied DIN plug and the twisted pair cable with plug for connection between the Master/Slave terminals. Refer to the figure shown below and note the correct polarity when making the connection.
14 A R A R M U N I T C - A L 8 0 C-AL80 5x12 S-tight screw (supplied with MB-23B) Fiber washer (supplied with MB-23B) supplied with MB-23B M4x12 binding head screw (supplied with MB-23B) 9. RA CK MOUNTING When mounting the C-AL80 Unit in an equipment rack, remove 4 plastic feet on the bottom plate and attach an optional MB-23B mounting bracket.
15 Cause • The supplied AC cord is not connected to the C-AL80 Unit's Power inlet and AC outlet. • The C-AL80 Unit is not correctly connected to the Remote Controller. • The C-AL80 Unit's Mode Selection switch is not set to "Alarm.
(L) : AC110 – 120 V, 50/60 Hz (H) : AC220 – 240 V, 50/60 Hz 3 W(60 mA) 6 W(60 mA) 32 channels, no-voltage make contact input, open voltage : 5V DC, short-circuit current : max.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il TOA Electronics C-AL80(L) è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del TOA Electronics C-AL80(L) - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso TOA Electronics C-AL80(L) imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul TOA Electronics C-AL80(L) ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il TOA Electronics C-AL80(L), ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del TOA Electronics C-AL80(L).
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il TOA Electronics C-AL80(L). Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo TOA Electronics C-AL80(L) insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.