USE & CARE INFORMATION
GUIDE D’UTILISATION ET D’ENTRETIEN
INFORMAZIONI SU USO E MANUTENZIONE
BEDIENUNGSUND PFLEGEANLEITUNG



Wolf Downdraft Ventilation Systems 5
Safety Instructions and Precautions 6
Wolf Downdraft Features 8
Wolf Downdraft Use & Care 9
Campanas extractoras de encimera de Wolf 14
Características de las campanas extractoras de encimera de Wolf 17
Uso y mantenimiento de la campana extractora de encimera de Wolf 18
Información de mantenimiento 21
Systèmes de ventilation escamotables Wolf 23
Instructions et mesures de sécurité 24
Caractéristiques des systèmes de ventilation escamotables Wolf 26
Utilisation et entretien des systèmes de ventilation escamotables Wolf 27
Cappe estraibili per aerazione Wolf 32
Precauzioni e istruzioni di sicurezza 33
Funzioni della cappa estraibile Wolf 35
Uso e manutenzione delle cappe estraibili Wolf 36
Informazioni sul servizio di assistenza 39
Randabsaugungssysteme von Wolf 41
Sicherheitshinweise und Vorsichtsmaßnahmen 42
Leistungsmerkmale der Randabsaugung von Wolf 44
Bedienung und Pflege von Randabsaugungssystemen von Wolf 45
Service Information 12 · Service après-vente 30 · Serviceinformationen 48

As you read this Use & Care Information, take particular note of the CAUTION and WARNING symbols when they appear. This information is impor tant for safe and efficient use of the Wolf equipment.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
In addition, this Use & Care Information may signal an IMPORTANT NOTE which highlights information that is especially important.
WOLF® is a registered trademark of Wolf Appliance, Inc.

W O L F DOWNDRAFT VENTILATION S Y S T E M S
Your purchase of a Wolf downdraft ventilation system attests to the importance you place upon the quality and performance of your cooking equipment. We understand this impor- tance and have designed and built your down- draft with quality materials and workmanship to give you years of dependable service.
C O N TA C T I N F O R M AT I O N
Before you begin using your downdraft, please take some time to read this Use & Care Information. It will be to your benefit to familiarize yourself with the safety practices, features, operation and care recommendations for your downdraft ventilation system.

S A F E T Y I N S T RU C T I O N S A N D P R E C A U T I O N S
This appliance must be grounded.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
Read this Use & Care Information carefully before using your new downdraft ventilation system to reduce the risk of fire, electric shock or injury to persons.
Ducted fans must always be vented to the outdoors.
To reduce the risk of fire, use only steel ductwork.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
Do not install this downdraft with the activating switch directly behind a burner or element. The minimum distance between the switch and edge of the burner should be 102 mm.
Use this downdraft only in the manner intended.
Do not wear loose-fitting or hanging clothing when operating this appli- ance. It may be ignited by burners or elements on the cooktop.
Before servicing or cleaning, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means can not be locked, securely fasten a promi- nent warning device, such as a tag, to the service panel.
Children should not be left alone or unattended in the area where this appliance is in use.
To reduce the risk of fire and properly exhaust air, be certain to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equip- ment manufacturer’s guideline and safety standards.

Do not repair or replace any part of this appliance unless specifically recommended in this book. All other service should be performed by a qualified technician.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING:
Smother flames with close-fitting lid, cookie sheet, or metal tray, then turn off the burner. Be careful to prevent burns. If the flames do not go out immediately, evacuate and call the fire department.
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
Never pick up a flaming pan – you may be burned.
Please read the specification label on the downdraft for further infor- mation and requirements.
Do not use water, including wet dishcloths or towels – a violent steam explosion will result.
TO REDUCE THE RISK OF COOKTOP GREASE FIRE:
You know you have a Class ABC extinguisher and you already know how to operate it.
unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
The fire is small and contained in the area where it started.
The fire department is being called.
You can fight the fire with your back to an exit.
cooking at high heat or when flambeing foods (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe').
frequently. Grease should not be allowed to accumulate on fan or filter.
cookware appropriate for the size of the surface element.

W O L F DOWNDRAFT F E AT U R E S
D O W N D R A F T CONTROLS
Control module and top cover have classic stainless steel finish
To activate your new Wolf downdraft, press the button on the control module.
Internal and remote blower options
Once the button is pressed, the downdraft blower will turn on at the last speed used, or on medium for first time use.
LED indicator lights on control module
To adjust the speed of the blower, press the , or button. The corre- sponding LED will illuminate to indicate the blower speed.
Filter clean timer lets you know when the filter needs cleaning
Delay-off feature automatically turns unit off after five minutes, chimney remains up
The LED next to the button on the control module will illuminate when it is time to clean the filters. This indicator light comes on after approximately 30 hours of operation. Refer to Filter Care on page 11.
229 mm chimney elevation
Stainless steel filter cover with dishwasher safe aluminum mesh filter
To reset the filter clean LED indicator, press the button.
D O W N D R A F T Model ICBDD36 shown

Stainless steel filter covers
Location of rating plate

W O L F DOWNDRAFT U S E & C A R E
D O W N D R A F T CONTROLS
D E L AY- O F F F E AT U R E
If the blower is on low speed and the button is pressed, the blower will stay on low speed for five minutes before turning off. The chimney will stay up.
The delay-off feature will allow the down- draft blower to continue operating at the selected speed for approximately five minutes after the button has been pressed. This feature allows you to leave the cooking area, while the downdraft system is still in operation, it will then shut off and the chimney will stay up.
If the button is pressed when the blower is off or when the chimney is down, no operation will take place.
If the button is pressed when the unit is already in delay-off mode the delay-off feature will be cancelled.
In delay-off mode, both the delay LED and the corresponding blower speed LED will be illuminated.
If the blower is on high speed and the button is pressed, the blower will stay on high speed for five minutes. It will then switch to low speed for an additional five minutes before turning off. The chimney will stay up.
If the blower is on medium speed and the
button is pressed, the blower will stay on medium speed for five minutes. It will then switch to low speed for an additional five minutes before turning off. The chimney will stay up.

Delay-off feature Filter clean LED indicator
Three-speed blower controls · Activation button · Downdraft control module

W O L F DOWNDRAFT U S E & C A R E
Most surfaces of your downdraft ventilation system are stainless steel or aluminum. Although these surfaces are resistant to most stains, they are not totally impervious to damage. Salt and some cooking liquids may pit and stain the surface. Always remove these spills immediately.
Using a clean cloth or sponge, wipe with warm water and mild detergent. Rinse and dry immediately. Apply protective polish, always in the same direction as the grain.
Spray Degreasers: Removes fingerprints and greasy spatters. Spray on a cloth and wipe the surface. Buff dry immediately to avoid streaks.
Hard Water Stains: Use white vinegar and water.
Protective Polish: Apply to the surface to maintain luster and protect from some food stains. Use a soft, non-abrasive stainless steel cleaner and apply with a soft lint-free cloth.

W O L F DOWNDRAFT U S E & C A R E
The aluminum mesh filters should be cleaned approximately every month, depending on use. The filter clean LED on your control module will illuminate when it is time to clean the filters. This indicator light comes on after approximately 30 hours of operation. You may need to clean the filters more often if your cooking style generates large amounts of grease, like frying foods or wok cooking.
The filters and filter covers are dishwasher safe and are designed to fit most dishwashers.
To remove the filters, push down on the filter frame while pulling the filter out away from the downdraft. Refer to the illustration below. Place the aluminum mesh filter and stainless steel cover into the dishwasher at approxi- mately 60ÞC, or hand wash, and use a biodegradable detergent. When filters are dry, reinstall using the reverse procedure.
Downdraft filter removal

SERVICE I N F O R M AT I O N
SERVICE I N F O R M AT I O N
For service in your area, contact your Wolf dealer or visit our website, wolfappliance.com to find the regional distributor by country.
B E F O R E C A L L I N G F O R S E RV I C E
Before calling your Wolf dealer or regional distributor, check the household fuse or circuit breaker to see if it has been blown or tripped and that the electrical connection to the appliance has not been disconnected. A power outage may also have caused a disruption in service.
When requesting information, literature, replacement parts or service, always refer to the model and serial number of your down- draft. This information is found on the product rating plate, located above the airbox on the front side of the unit. Refer to the illustration on page 8. Record the rating plate information below for future reference.
C O N TA C T I N F O R M AT I O N
Wolf Dealer and Phone
The information and images in this book are the copyright property of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
Model Number · Serial Number · Installation Date
Pagine di riferimento in questo manuale: produttore, supporto e download.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.