C l a r e n d o n & A s h d o n L o g E f f e c t S t o v e R a n g e C on v en t io n al F l ue With upgradeable control valve I ns t r uc t io n s f or U se , I ns t a ll a ti o n a nd S er v i .
2 CONTENTS COVERING THE FOLLOWING MODELS CLARENDON – 8611LUC – P8611LUC / 8612LUC – P8612LUC ASHDON – 8613LUC – P8613LUC / 8614LUC – P 8614LUC PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER .
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must be carried out by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, appropriate Codes of Practice and in accordance with the manufacturer’s instructions.
6. CLEANING THE FIRE WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL IN A COLD CONDITION. THE STOVE RETAINS ITS HEAT FOR A CONSIDERABLE TIME AFTER SHUTDOWN. NOTE: THE CAST IRON DOOR IS HEAVY, TAKE EXTREME CARE WHEN HANDLING. 6.1 Remove the door by undoing the four dome nuts using the tool supplied and place to one side.
6 7.2 Place log B on the left-hand side of the burner with the location bar on the underside of the log fully located in the long slot of the burner. Make sure the log is as far to the left as possible.
7.8 Carefully insert the front coal retainer into the front panel of the firebox. Take care not the scrape/damage the logs. This coal retainer sits in two brackets. Ensure it is fully inserted, leaving approximately a 4 mm gap between the firebox ledge and the bottom of the coal retainer.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: CLARENDON – 8611LUC – P8611LUC / 8612LUC – P8612LUC ASHDON – 8613LUC – P8613LUC / 8614LUC – P 8614LUC Model Gas Gas Working NOX Aeration Injector Gas Rate Input kW (Gross) Country CAT.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force and must be a minimum of 127mm in diameter. (5"). 1.2 The minimum effect height of the flue or chimney must be 3 metres (10ft).
10 IMPORTANT: ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS OF THIS BOOKLET. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 11, REPLACING PARTS.
11 3.6 The flue system may now be connected to the stove. Ensure that all joints are sealed with a suitable fire resistant sealant. It is also recommended that a physical retention method be used at the flue spigot joint, self-tapping screws being favoured.
12 5.4 Place log D across from the rear log A to log B on the left- hand side. There are cut-outs in both logs for location. See diagram 6. 5.5 There are two ash panels which lay across the front of the burner skin. Place the panel with the flat edge facing the left side of the firebox.
13 6. LIGHTING 6.1 Full instructions are given in the User section under Lighting the Stove. INSTALLATION INSTRUCTIONS INSTALLATION.
1. COMMISSIONING 1.1 Close all openable doors and windows in the room, ignite the stove and operate on maximum for 10 minutes. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening by viewing through the sight hole.
15 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations.
16 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS NO SPARK IGNITION FUNCTIONAL CHECK 2 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clear the area. From Ignition Fault Finding Chart Part 1.
17 SERVICING INSTRUCTIONS REPLACING PARTS 1. GENERAL 1.1 All principal components can be replaced without removing the stove from its installation, although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further.
18 SERVICING INSTRUCTIONS REPLACING PARTS 3.7 To remove the thermocouple, undo the retaining nut and withdraw the thermocouple. Undo the thermocouple from the back of the gas valve. See Diagrams 5 and 6. Reassemble in reverse order. Do not overtighten.
19 SERVICING INSTRUCTIONS REPLACING PARTS 6.6 Check all joints for gas leaks. Check the operation of the thermocouple and ignition lead. 7. MAGNETIC SAFETY VALVE 7.1 Turn the gas supply off at the isolation device. Undo the thermocouple connection from the back of the gas valve.
20 SERVICING INSTRUCTIONS REPLACING PARTS 9.3 Undo the two screws at the back of the firebox and carefully withdraw the bracket. 9.4 Disconnect the two slender wires. Undo the two taptite screws and remove the sensor and the two plastic spacers. See diagram 16.
21 SERVICING INSTRUCTIONS REPLACING PARTS 11. CHANGING BETWEEN GAS TYPES In order to change between gas types, it will be necessary to change the following items.
22 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Stovax 705088 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Stovax 705088 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Stovax 705088 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Stovax 705088 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Stovax 705088, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Stovax 705088.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Stovax 705088. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Stovax 705088 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.