Manuale d’uso / di manutenzione del prodotto CVW-EXA224 del fabbricante Sanyo
Vai alla pagina of 30
CVW-EXA284 / CVW-EXA224 (H: 84 7/8”, L: 96 3/8”) / (H: 84 7/8”, L: 144 5/8”) MULTI-DECK FRESH PRODUCE CASES INSTALLATION & SERVICE MANUAL REMOTE TYPE DISPLAY CASE 2010 CVW-EXA184 / CVW-EXA.
2 Activity Safety Precautions In order to prevent any i njuries to person, equi pment and/or damage to the SANYO Cases, sections requi ring additi onal care to be undertaken will hav e one or all of t.
3 T ABLE OF C ONTENTS 1 SPECIFICAT IONS .................................................................................................................................................. 5 1.1 CVW-EXA284 / CVW-EXA224 ..................................
4 6 CARE AND CLEANING GUIDELINES ................................................................................................... .......... 21 6.1 E XTERIOR P ANELS (D AILY C LEANING ) ..............................................................
5 1 Specifications 1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”) Model Name CVW-EXA284 CVW-EXA224 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce) Cooling Capacity: 1224 BTU/h/ft.
6 1.2 CVW-EXA184 (H: 80 7/8”, L: 96 3/8”) / CVW-EXA124 (H: 80 7/8”, L: 144 5/8”) Model Name CVW-EXA184 CVW-EXA124 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh produce) Cooling Capacity: 1146 BTU/h/ft. ( 2682W ) 1146 BTU/h/ft.
2 Dimensions 2.1 External Dimensions 2.2 Footprint ① Waste Outlet ② Electrical Connection ③ Refrigeration Outlet * Dimensions given in inches and millimeters (mm in parentheses).
2.3 External Dimensions 2.4 Footprint * Dimensions given in inches and millimeters (mm in parentheses). CVW-EXA184 / CVW-EXA124 ① W a s t e O u t l e t ② E l e c t r i c a l C o n n e c t i o n .
9 3 Unloading and Carpentry P rocedures 3.1 NSF Certification The SANYO Cases described in this manual are built to meet the requirements of American Nation al Standard/NSF International Standard 7.
10 3.5 Aligning Cases WARNING SANYO Cases are heavy and bulky, an d require at least two people for unloading, mov ing, and inst allation. Do not walk on the top of the SANYO Case s. Walking on the top of the SANYO Case may lead to serious injury and/or damage to the SANYO Case.
11 3.7 Joining Instructions 3.7.1 Applying gasket (for connecting cases or installing side panels). ① Make sure that all SANYO Cases are resting level. ② Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.
12 3.7.2 Connecting cases. ① Apply gasket as described above. ② Connect cases by using the attached bolts, joint covers, and nuts. Silicone seal Note: Gasket ends that are open must be sealed off by applying silicone at the installation site. Note: Connection point must be silicone sealed.
13 3.8 Installing Patch Ends 1. Apply gasket to case body (per previo us inst ructions). 2. If present, remove protective film from inside wall of Patch End. 3. Place Patch End to line up with bolt holes. 4. From inside unit ratchet in M8 & op tional M5 bolt into Patch End until secure.
14 3.9 Installing Kickplate 1. Align the mounting hole in the Kickplate with the sl ot in the Kickplate Mounting Bracket on the SANYO Case and tighten accordingly.
15 3.10 Installing Handrail and Bumper Attaching the Bumper 1. Attach Maintenance Bumper (length 39-3/8 inches ) to Bumper Brackets over the electrical connection box (“Raceway”) on each SANYO Case. Th e Raceway is located on the right end of each SANYO Case.
16 4 R efrigeration, Plumbing & Electrical P rocedures 4.1 Piping (Plumbing, Refrigeration) ● U-trap installation Install U-trap referring to the drawing below.
17 4.2 Electrical Data Please refer to Specifications sectio n and nameplate attached to merchand iser for electrical information. 4.3 Electrical – Guidelines & Precautions All wiring and electrical field wo rk must comply with the National Electrical Co de (“NEC”) and other applicable local codes.
18 4.4.2 Wiring Diagram CVW-EXA284/184 C VW-EXA224 / 124.
19 5 Operation 5.1 Load Limits In order to maintain proper temperatur e and unit performance, the Dual Air Curt ains in each SANYO Case must remain unobstructed: Do not stock shelves beyond the marked load limits. Do not block Honeycombs or Return Air Grilles.
20 Installing FDA/NSF Thermometer Suggested locations for the thermometer re quired by NSF/ANSI 7 and the FDA Food Code are indicated above. It is the respon sibility of the Purchaser/End User of the SANYO Case to determine the location wi th in the food storage area that best meets these code requirements.
21 6 Care and Cleaning Guidelines In order to keep SANYO Cases sanitary and in good working order, we recommend thorough periodic cleaning as follows: 6.1 Exterior Panels (Daily Cleaning) a. Exterior panels should be cleaned wi th water only. Wet a soft cloth and wring it out to wip e down panels.
22 Please make sure to check and clean the drain trap at least once a month. Remove any material that has gathered in the drain trap and dispose of it.
23 7 Service 7.1 Replacing Fan Motors and Blades HAND PROTECTION REQUIRED! Activities to be undertaken require finger and palm protection to prevent personal injuries. To replace the fan motors: ① Remove the outer Air Curtain Duct Cover and socket covers.
24 For models with Standard-type (AC) Fan Motors: CVW-EXA124/224 CVW-EXA184/284 No. Part Name Model Part Number Quantity Quantity Hex Nut - HN44162520U18 5 3 Spring Washer - SW49266225U18 5 3 ① -a .
25 For models with high-efficiency-type (DC) fan motors: CVW-EXA124/224 CVW-EXA184/284 No. Part Name Model Part Number Quantity Quantity Hex Nut - HN44162520U18 5 3 Spring Washer - SW49266225U18 5 3 .
26 7.2 Replacing Electronic Ballasts CVW-EXA124/224 CVW-EXA184/284 Type Model Part Number Quantity used Quantity used 3-lamp QHE3X32T8/UNV ISN-SC-1-CC-B 8FC05400000301 2 - 2-lamp QHE2X32T8/UNV ISN-SC-.
27 7.3 Replacing Fluorescent Lamps The unit comes with covers placed over each fluorescent lamp. Ensure that these covers are placed over the new lamps before reinstallation. LAMP END CAP CAUTION! Always use Sanyo lamp covers and end caps wh en replacing lamp covers and end caps.
28 7.3 Expansion Valve D a n f o s s MODEL Valve Body P.N. Body Type Refrig erant Valve Orifice P.N. Orifice Type 9FT2450000110 TUAE 068U2287 R404A 9FT2450000100 TU7 068U1037 CVW-EXA124 CVW-EXA224 9FT.
29.
SANYO E & E Corporation 2001 Sanyo Avenue, San Diego, CA 92154-6229 USA Toll Free USA 800-95-SANYO (72696) · Fax 619-661-4183 http://us.sanyo.com/Food-Solutions Manufactured and Distributed by: MCVW V01.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sanyo CVW-EXA224 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sanyo CVW-EXA224 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sanyo CVW-EXA224 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sanyo CVW-EXA224 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sanyo CVW-EXA224, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sanyo CVW-EXA224.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sanyo CVW-EXA224. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sanyo CVW-EXA224 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.