Manuale d’uso / di manutenzione del prodotto PRO-9671FT del fabbricante Audiovox
Vai alla pagina of 22
Model PRO-9671FT Installation Manual 4 Channel Remote Car Starter With Full Feature Alarm System Installation Instructions This Unit Is Intended For Installation In V ehicles With 12 V olt Negative Ground Electrical Systems, Gasoline Engines, And Automatic T ransmissions Only .
The PRO-9671FT Remote Start/Alarm System is designed to be used with Automatic Transmission V ehicles Only! The unit provides no output for glow plug pre-heat and may not be desirable for diesel vehicles.
drill a 1/4" hole in the desired location and pass the connector end of the LED through the hole and toward the control module. Press the LED firmly into place until it is fully seated in the mounting hole.
The PRO-9671FT is to be used in vehicles with AUT OMA TIC TRANSMISSIONS only! Although this combination Alarm/Remote Start unit is a sophisticated system with many advanced features, IT MUST NOT be installed into a vehicle with a manual operated transmission.
BLUE Wire: Ignition 1 Output Connect this wire to the ignition 1 wire from the ignition switch. This wire will show +12 volts when the ignition key is turned to the to the "ON" or "RUN&.
WIRING CONNECTIONS: Multi Pin Accessory Input/Output Harness White w/ Red T race Wire: Parking Light Flasher Feed This wire is the common contact of the on board p arking light flasher relay . If the vehicle you are working on has +12 volt switched parking lights, connect this wire to a fused + 12 volt source.
Purple Wire: (+) Door Trigger Input If the vehicle's door courtesy light switches + 12 volts when the door is opened, (Most Fords and some Imports), you must connect this wire to the positive output from one of the vehicle's door pin switches.
General Motors V A TS By-Pass Diagram Light Blue Wire: Ignition 3 Output This wire provides a 300mA ground output that becomes active 3 seconds before the Remote Start Unit initializes, and remains grounded while running plus an additional 4 seconds after the Remote Start Unit turns off.
Green w/ White trace Wire: Entry Illumination Ground Output This wire provides a 30 second ground output (300 mA Max.) whenever the remote is used to disarm the alarm or to unlock the doors and provides a continuous pulsed output whenever the alarm is triggered.
Orange Wire: Ground When Armed Output This wire provides a 300 mA ground output when the alarm circuit is armed to control the starter inhibit relay . Connect the Orange wire to terminal #86 (orange wire) of the relay provided.
Black Wire: Chassis Ground Source Connect the Black wire to a known vehicle ground source or to a solid clean metal part of the chassis. Be certain to remove any paint or grease and secure this wire with a self taping screw and ring terminal.
Dark Blue Wire: Delayed 300mA Pulsed Channel 2 Output The Dark Blue wire supplies a 300mA ground pulsed output whenever channel two of the receiver is accessed.
2 Pin Control Switch: (Red Connector) The Black & Black w/White Trace wires loaded in the two pin red connector enable the operation of the Remote Start unit. When the Black w/ White Trace wire is grounded, the remote start unit is operable. When this wire is open from ground, the remote start is disabled.
3 Wire Positive Switched Door Locks: In this application, the Red wire of the two pin harness provide sa+1 2 volt pulse during the disarming sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from the factory door unlock switch to the factory door unlock relay .
ALARM SELECT ABLE FEA TURES NOTE: The Alarm Selectable Features and Remote Start Selectable Features p rogramming steps following are based on transmitter button 1 being programmed for channel 1 and transmitter button 2 being programmed for channel 2.
REMOTE ST ART SELECT ABLE FEA TURES RF Programmable Features: LED Pattern 1 x Pause etc. 2 x Pause etc. 3 x Pause etc. 4 x Pause etc. 5 x Pause etc. 6 x Pause etc.
Multi Coil Pack Adaptor: (Optional) The multi coil pack adaptor is designed for use with vehicles having multiple ignition coils where a single point tach signal is unavailable. T o use the adaptor , the Green/Black wires must connect to the negative side of the ignition coil(s).
TESTING YOUR INST ALLA TION: CAUTION!! The following procedure must be performed after the installation of an Audiovox Remote Start Device. It is the responsibility of the installing technician to complete these tests. Failure to test the unit in the following manner may result in personal injury , property damage, or both.
CAUTION! REMEMBER TO RECONNECT THE BROWN/BLACK WIRE TEMPORARIL Y DISCONNECTED IN STEP 3 DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERA TION OF THE NEUTRAL SAFETY ST ART FEA TURE.
KEY IN SENSOR CIRCUITS: If the vehicle you are working on does not have or you cannot locate the ECM reference wire, there are two alternatives available. Although not preferred, the vehicle Key In Sensor may be reconfigured to allow a margin of safety and will prevent the vehicle with a Mechanical Neutral S tart Switch from starting in gear .
METHOD 2 T o connect to the key in sensor circuit as shown for method 2: A. Locate the control wire that connects the drivers door pin switch to the key in sensor switch. B. Cut this wire and connect the ignition cylinder side to chassis ground. C. Locate the key in sensor switch wire that connects the chime module to the ignition cylinder .
OUTPUT GREEN/BLACK (-) TO CHANNEL 3 CONTROL RELA Y GREEN RED DOOR LOCKS (See page 13) RED BLUE L.E.D. (See page 13) BLUE RED GREEN BLACK SHOCK SENSOR (See page 13 & 14) BLACK BLACK w/WHITE CONTROL.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Audiovox PRO-9671FT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Audiovox PRO-9671FT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Audiovox PRO-9671FT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Audiovox PRO-9671FT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Audiovox PRO-9671FT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Audiovox PRO-9671FT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Audiovox PRO-9671FT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Audiovox PRO-9671FT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.