128-7760 1 of 16 1 Model AS 9076 Installation Manual Remote Start Upgrade Module Installation Instructions This Unit Is Intended For Installation In V ehicles With 12 V olt Negative Ground Electrical Systems, Gasoline or Diesel With T rue T ach Reference And Automatic T ransmissions Only .
128-7760 2 of 16 2 This Remote Start/Keyless Entry Upgrade System is designed to be used with Automatic Transmission Vehicles Only! The unit provides a selectable ignition control that allows a 10 second output for glow plug preheat which may be required for certain diesel vehicles, (see selectable feature #5).
128-7760 3 of 16 3 WIRING THE 6 PIN MAIN POWER HARNESS: Note: Do not remove the fuse holders from this wire harness. Fuses must be used and located as close as possible to the power source for adequate protec- tion of the vehicle. Fused RED w/ WHITE TRACE WIRE: + 12 volt Battery 1 Source Locate the vehicle battery wire(s) at the ignition switch.
128-7760 4 of 16 4 SEE NEUTRAL ST ART SAFETY TEST FOR FURTHER DET AILS. BLUE Wire: Ignition 1 Output Connect this wire to the ignition 1 wire from the ignition switch.
128-7760 5 of 16 5 the Black w/ White wire is at open circuit through the control switch, the remote starter is disabled. Connect the Black w/ White tracer wire to one of the wires from the back of the previously mounted control switch. Connect the remaining wire of the control switch to chassis ground.
128-7760 6 of 16 6 This wire should be connected to the ignition input of the alarm system. The Yellow w/ Black wire output will allow you to remote start the vehicle while leaving the alarm armed, and to lock/ unlock the doors while running under control of the remote start unit.
128-7760 7 of 16 7 NOTE: These wires are typically White w/ Black trace and Violet w/ Y ellow trace, however in later model Cadillacs, they are run through an orange sleeve, and are either both Black, both Y ellow , or both White wires. Consult the factory service manual for additional information.
128-7760 8 of 16 8 T achometer Input W iring Det ail WIRING THE 4 PIN AUXILIARY OUTPUT HARNESS The auxiliary 4 pin connector provides low current outputs to control various functions in the vehicle during different stages of the Remote Start unit's operation.
128-7760 9 of 16 9 1. Programmable Features: Feature Lts Flash 1X Lts Flash 2X Lts Flash 3X Lts Flash 4X Default 1 Run Time 5 Min. 10 Min. 15Min. 20 Min. 10 Min 2 Park Lights On Steady Flash Steady 3 Input Check Voltage Tach Tach 4 Voltage Level > 0.
128-7760 10 of 16 10 This Remote Car Starter will learn the tach rate of most vehicles single ignition coils, multiple coil packs, and or single injector. To learn tach; 1. Start with the ignition switch in the "OFF" position and the programming switch in the "ON" position.
128-7760 11 of 16 11 Multi Coil Pack Adaptor: (Optional) The multi coil pack adaptor is designed for use with vehicles having multiple ignition coils where a single point tach signal is unavailable. T o use the adaptor , the Green/Black wires must connect to the negative side of the ignition coil(s).
128-7760 12 of 16 12 TESTING YOUR INST ALLA TION: CAUTION!! The following procedure must be performed after the inst allation of an Audiovox Remote S tart Device. It is the responsibility of the installing technician to complete these tests. Failure to test the unit in the following manner may result in personal injury , property damage, or both.
128-7760 13 of 16 13 this vehicle. The information concerning the Mechanical Neutral Safety Switch provided below will help you to determine if the vehicle you are working on has this type of safety switch and will provide alternate wiring methods to accommodate this situation.
128-7760 14 of 16 14 circuits may be used only if the above circuit is not available. NOTE: When completing an installation using either of the following key in sensor circuits, if the operator inserts the ignition key while the vehicle is running under the control of the Remote S tart, the vehicle will shut down.
128-7760 15 of 16 15 C. Locate the key in sensor switch wire that connects the chime module to the ignition cylinder . D. Cut this wire and connect the ignition cylinder side to the Remote S tart Negative Safety Shut down Wire Gray/Black, using a 4002 series diode as shown above.
128-7760 16 of 16 16 © 2006 Audiovox Electronics Corp., Hauppauge, N.Y . 1 1788 128-7760.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Audiovox 128-7760 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Audiovox 128-7760 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Audiovox 128-7760 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Audiovox 128-7760 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Audiovox 128-7760, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Audiovox 128-7760.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Audiovox 128-7760. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Audiovox 128-7760 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.