® VS5004/VS5008 Sequential Switcher INSTALLATION/OPERATION C808M-G (4/05).
2 C808M-G (4/05) Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Models .
C808M-G (4/05) 3 Description The VS5004 and VS5008 sequential switchers are designed to switch up to four (VS5004) or eight (VS5008) cameras manually or automatically to one or two monitors with automatic response to alarm inputs. Both versions are Coaxitron ® compatible and can be placed on a desktop or rack mounted.
4 C808M-G (4/05) Installation T ERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Make all equipment connections. Refer to Figure 1 (VS5004) or Figure 2 (VS5008). VS5008 only: When configured for one-monitor operation, the monitor must be connected to the MON 2 output.
C808M-G (4/05) 5 Figure 2. VS5008 T erminated Camera Inputs - One Monitor Figure 3. VS5004 Alarm Connections VS5008 (REAR) MON 1 MON 2 MON X CAMERAS 87654321 12 V AC INPUT ALARM INPUT COM ALARM OUT 12345678 NOTE: MON 1 MUST BE TERMINA TED.
6 C808M-G (4/05) Figure 4. VS5008 Alarm Connections 12 V AC INPUT ALARM INPUT COM ALARM OUT 12345678 MON 1 MON 2 MON X CAMERAS 87654321 UP TO EIGHT ALARM INPUTS (ALARM INPUT FROM MOTION DETECTOR, DOOR CONT ACT , ETC., THROUGH NORMALL Y OPEN SWITCH). EACH ALARM DEVICE MUST BE CONNECTED TO THE "COM" TERMINAL.
C808M-G (4/05) 7 LOOPING CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Convert the switcher to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and terminated inputs may be mixed. a. Remove the cover . b. Remove the rear panel of the chassis.
8 C808M-G (4/05) Figure 5. Looping Conversion Modification Figure 6. VS5004 Looping Camera Inputs - One Monitor 75-OHM RESISTOR REAR PANEL (SWITCHER) BNC CONNECTOR CLIP HERE FOR EACH CHANNEL MON 1 MO.
C808M-G (4/05) 9 Figure 7. VS5008 Looping Camera Inputs - One Monitor T ERMINATED CAMERA INPUTS AND T WO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover . b. Remove the rear panel of the chassis.
10 C808M-G (4/05) 4. Set the ALARM switch to the ON position. NOTES: • With all channel switches set to the AUTO position, both monitors immediately switch to the alarmed channel and the associated LED blinks. Multiple alarmed channels sequence every five seconds (VS5004) or three seconds (VS5008).
C808M-G (4/05) 11 Figure 9. VS5004 T erminated Camera Inputs - T wo Monitors Figure 10. VS5008 T erminated Camera Inputs - T wo Monitors MON 2 MON 1 MON 2 43 2 1 ALARM 12 V AC INPUT IN 1 2 3 4 OUT 6 C.
12 C808M-G (4/05) LOOPING CAMERA INPUTS AND T WO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover . b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis.
C808M-G (4/05) 13 7. Connect the AC adapter to the 12 V AC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 V AC (VS5004 or VS5008) or 230 V AC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing.
14 C808M-G (4/05) COAXITRON CONTROL To convert for use with a Coaxitron transmitter , do the following: 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover . b. Remove the rear panel of the chassis.
C808M-G (4/05) 15 6. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs should have their channel switch set to the BYP ASS position.
16 C808M-G (4/05) Figure 13. VS5004 with Coaxitron Control Figure 14. VS5008 with Coaxitron Control COAXITRON® RECEIVER MON 1 MON 1 MON 2 43 2 1 ALARM 12 V AC INPUT IN 1 2 3 4 OUT 6 COMMON 5 LOOPING .
C808M-G (4/05) 17 Specifications VIDEO Inputs T erminating (75 ohms) or looping Outputs Monitor 1 75 ohms Monitor 2 VS5004 Hi Z VS5008 75 ohms Monitor X VS5008 Coaxitron transmitter (nonamplified) o.
18 C808M-G (4/05).
PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco VS5008 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco VS5008 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco VS5008 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco VS5008 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco VS5008, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco VS5008.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco VS5008. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco VS5008 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.