Manuale d’uso / di manutenzione del prodotto EH3512 del fabbricante Pelco
Vai alla pagina of 20
® INST ALLA TION EH3508/EH3512/EH3515 Series Environmental Enclosure C478M-M (1/06).
.
C478M-M (1/06) 3 Important Safety Instructions Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Only use attachments/accessories specifi ed by the manufacturer.
4 C478M-M (1/06) Description The EH3508/EH3512/EH3515 Series are indoor/outdoor light-duty camera enclosures designed for use with various cameras on the market and accommodate fi xed focal length or motorized zoom lenses, with or without auto-iris operation.
C478M-M (1/06) 5 Installation The following items are supplied to mount the enclosure: 2 1/4-20 x 0.500-inch hex head screws 2 Flat washers 2 Split washers The following items are supplied to mount the camera: 2 1/4-20 x 0.375-inch Phillips screws Figure 1.
6 C478M-M (1/06) Figure 2. Exploded View of EH3500 Series Assembly FLAT WASHER SPLIT WASHER HEX HEAD SCREW EM1450 WALL MOUNT (NOT SUPPLIED) GLANDS PHILLIPS SCREWS CAMERA SLED SLED MOUNTING SCREWS.
C478M-M (1/06) 7 Perform the following steps to install the enclosure, camera, and lens: 1. Unlatch and open the lid. 2. Remove the camera sled from the rail of the enclosure. a. Loosen the screws that hold the camera sled in place. b. Slide the sled forward so it can be lifted out over the screws.
8 C478M-M (1/06) 9. If the enclosure has accessories that require power, you will need to access the PC board. T o remove the cover, insert a screwdriver into the slot on top of the cover and lift the cover off.
C478M-M (1/06) 9 Figure 4. EH3508-1/-2/-3 Wiring Diagram 1 2 3 4 5 6 7 8 9 10 HEA TER DEFROSTER INPUT , AC HIGH INPUT , AC LOW (NEUTRAL) 24/120/230 V AC MODELS.
10 C478M-M (1/06) Figure 5. EH3512 Series Wiring Diagram NOTE: Blower applies to -1/-2/-3 models only. 1 2 3 4 5 6 7 8 9 10 HEA TER DIODE BRIDGE INPUT , AC HIGH INPUT , AC LOW (NEUTRAL) 24 V AC MODEL .
C478M-M (1/06) 11 Figure 6. EH3515 Series Wiring Diagram NOTE: Blower applies to -1/-2/-3 models only. 1 2 3 4 5 6 7 8 9 10 INPUT , AC HIGH INPUT , AC LOW (NEUTRAL) 120 V AC MODEL DEFROSTER BLOWER REA.
12 C478M-M (1/06) T able A. Enclosure Accessory Wiring Distances The following cable sizs are the minimum recommended for sue with the heater and defroster combination in enclosures in the EH3508 Series, and the heater, defroster , and blower combination in enclosures in the EH3512 Series and Eh3515 Series only .
C478M-M (1/06) 13 T able A. Enclosure Accessory Wiring Distances (Continued) Model Number Input V oltage Accessories Max. Power Consumption Cable Size Cable Distance EH3515-3 230 VAC at 50 Hz Heater D.
14 C478M-M (1/06) Example: An enclosure that requires 30 VA and is installed 94 feet (28 m) from the transformer would require a minimum wire gauge of 20 A WG.
C478M-M (1/06) 15 Operation If your enclosure has a thermostatically controlled heater, the thermostat is set to turn on at 50°F (10°C) and to turn off at 80°F (27°C).
16 C478M-M (1/06) Specifications Camera Mounting Multiple holes on adjustable camera sled; camera sled mounts in threaded strip for easier removal and can be inverted for additional camera elevation Camera and Lens Size Accommodates camera and lens combinations (including BNC connector) up to 2.
C478M-M (1/06) 17 Figure 7. EH3508, EH3512, EH3515 Dimension Drawing 5.14 (13.05) 3.88 (9.86) 2.00 (5.08) A B C EH3512 EH3515 A 14.75 (37.47) 17.75 (45.09) B 12.75 (32.38) 15.75 (40.00) C 1 1.25 (28.57) 14.25 (36.20) EH3508 10.75 (27.30) 8.75 (22.22) 7.
18 C478M-M (1/06) REVISION HISTORY Manual # Date Comments C478M-J 6/99 Moved the EH3508 Series enclosures from manual C1435M-A. Updated the description, installation instructions, and specifications. Updated wiring diagrams and dimension drawing. Modified per ECO 99-4749, which changed heater and defroster design.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
® Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco EH3512 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco EH3512 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco EH3512 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco EH3512 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco EH3512, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco EH3512.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco EH3512. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco EH3512 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.