S T AND A LONE A CCESS C ONTROL ECP190 / ECP290 DOOR CONTROLLERS ® Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity . ECP190 / ECP290 DOOR CONTROLLERS Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity .
2 contents Explanation of Noralsy ® Access P asses 3 General Door Controller Inf ormation 4 ECP 190 Door Controller schematic 5 ECP 290 Door Controller schematic 6 How to use the T elpro ™ progr am.
3 N ORALSY ® A CCESS P ASSES Site Code The number of each and e very Access Pass is visib le. Just b y looking at it, y ou kno w which Access Pass y ou have .
4 ® Noralsy ECP Door Controllers 1 2 3 1 2 4 5 6 3 1 2 3 1 2 4 3 1 2 3 1 2 4 5 3 1 2 3 1 2 3 1 2 1 2 3 1 2 4 3 1 2 4 5 3 1 2 4 5 6 3 1 2 4 5 6 7 3 1 2 4 5 6 7 8 3 1 2 1 2 4 5 6 3 65432 1 654321 1 Standardisation of T erminal Numbering Place Noralsy unit on a flat surface with PCB facing skywards.
12345 6 = 12345 6 32 1 21 123456 32 1 1O N 5 4 3 2 1 1 2 3 4 5 = 32 1 2 1 (—) (+) 5 ® ECP190 Door Controller for 1 n 0 Door/Access Point ■ Capacity 999 Users ELEC/INST/801 Supply 12V DC ± 10% Dimensions 103 L x 106 W x 83 D (6 DIN units) W eight 0.
6 ® ECP290 Door Controller for 2n 0 Doors/Access Points ANTI-P ASSBA CK FEA TURE A V AILABLE Supply 12V DC ± 10% Dimensions 163 L x 106 W x 83 D (10 DIN units) W eight 0.
7 ® Programming Stand-Alone Access Control Systems using TELPRO™ Programmer . MLP3 Proximity MIR Infra-Red MILB Card Reader LB20 Swipe Card ECP190 ECP290 ECP100 ECP200 Access Contr ol Modules, Read.
Important : Each press of a button is confirmed (as r eceived) by the r eader/r eceiver by a single beep. Press the TELPRO ™ buttons gently . Programming using TELPRO ™ as a remote wire-free programmer .
9 PROGRAMMING 08 Example Basic configuration, just do it! Basic configuration, just do it! seconds ECP Door Controller with ACCESS P ASS CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected via the TELPRO programming keypad. ■ Site Code is always a 5 digit number .
10 *See Tip Wizard on page 13 * STEP 4 Y ou must now inform the Door Controller of the Site Code of the Access Passes supplied. The Site Code is always stored in Slot N o . 01. The Site Code is always a 5 digit number . Check the Access Pass Information Sheet delivered with the Access Passes.
11 After a beep enter on the TELPRO: A sharp beep confirms that you have correctly deleted Holder Number 074. Pr ogramming mode beep - every 4 seconds - resumes. Example C: V alidation of 1n o . Access Pass Y ou have just received the additional Access Pass order ed for Alan Jones who had lost his earlier in the week.
12 ECP290 D OOR C ONTROLLER FOR 2 D OORS – I MPORT ANT I NFORMA TION FLICKING PROGRAMMING SWITCH SW1. The access control readers on both doors will star t to beep ev er y 4 seconds indicating programming mode status . Only 1 n o . access point (door) can be programmed at a time .
13 Mode 4 - Dual Security , Access Pass + K e ypad Code 00 4 00508 = Set-Up , Mode 4 È Rela y output time in seconds User required to present a valid access pass and then enter a v alid code or vice versa in order to gain access . A maximum of 27n o .
14 ® ® Noralsy® ECP Door Controller 32 1 2 1 32 1 654321 65432 1 1 2 4 5 6 3 6 5 3 2 1 4 32 1 + 21 32 1 (—) (+) Fail Safe Locking ECP190 Door Controller ECP190 Door Controller ECP190 Door Controller Automation Control / V olt Free Entrance/Exit Access point requiring access contr ol on both sides of the door , gate or barrier .
15 ® ® 32 1 (–) (+) 21 32 1 Locking ECP190 Door Controller Noralsy® ECP Door Controller DIN Rail Mounting W all Mounting DIN Rail ELEC/INST/805 ELEC/INST/806 ELEC/INST/807.
® ® 16 Noralsy® DIN Rail Power Supplies ELEC/INST/808 ELEC/INST/809 ELEC/INST/810 ELEC/INST/811 ARE121 12V AC/DC 1 AMP MAXIMUM OUTPUT ARE122 12V DC 2 AMP MAXIMUM OUTPUT ARS122 12V DC .
17 ® Noralsy® Powering ECP Door Controller(s) using Noralsy® DIN Rail Power Supply Units ELEC/INST/812 ARE121 + ECP190 ARE122 + ECP290 ELEC/INST/812A.
18 ECP190 DOOR CONTROLLER with KEYP AD ACCESS CODE CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected directly via the keypad. ■ Master Code (Programming Access Code) is always a 5 digit number . ■ Master Code is always stored in Slot N o .
19 After a beep enter on the keypad: A sharp beep confirms that you have deleted Alan’ s code. Programming mode beep - every 4 seconds - resumes. After a beep enter on the keypad: A sharp beep confirms that you have deleted Alex’ s code. Programming mode beep - every 4 seconds - resumes.
N.A.C.D. Limited Unit 10, Avebury Court, Mark Road, Hemel Hempstead, Her ts HP2 7T A. TEL: 01442 211848 F AX: 01442 212776 EMAIL: sales@nacd.co.uk WEB: www.nacd.co.uk Our policy is one of continuous product impr ovement, we reserve the right to change specifications and prices without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco ECP190 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco ECP190 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco ECP190 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco ECP190 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco ECP190, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco ECP190.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco ECP190. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco ECP190 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.