Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 Inte.
2 Pelco Manual C1487M-D (7/99) CONTENTS Section Page GENERAL .......................................................................................................................... 4 IMPORT ANT SAFEGUARDS AND WARNINGS ..............................
Pelco Manual C1487M-D (7/99) 3 Section Page LIMIT ST OPS .................................................................................................... 41 PARK TIME MINUTES ........................................................................
4 Pelco Manual C1487M-D (7/99) GENERAL IMPORT ANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
Pelco Manual C1487M-D (7/99) 5 COMP ASS TOOL SAFETY BRACKET CONDUIT FITTING & LOCK NUT T -RAIL CLIP Figure 2. Back Box Parts Figure 1. In-Ceiling Components BACK BOX DOME DRIVE LOWER DOME IN-CEILI.
6 Pelco Manual C1487M-D (7/99) BACK BOX DOME DRIVE LOWER DOME Figure 3. Pendant Components PENDANT MODELS The Spectra II™ dome and Spectra Lite™ dome shipping cartons contain three boxes, plus the C1487M-D system manual that covers everything in the system (back box, dome drive, and lower dome).
Pelco Manual C1487M-D (7/99) 7 DESCRIPTION Spectra II™ and Spectra Lite™ domes are capable of the following: • 360 ° pan rotation • preset positioning • +2 to -92 ° tilt • variable speed The in-ceiling models can be installed in hard ceilings or standard 2' x 2' (61 cm x 61 cm) suspended ceilings.
8 Pelco Manual C1487M-D (7/99) SPECTRA LITE™ PENDANT COMPONENTS BB5T-PB Black pendant-mount back box (CE, UL, cUL) BB5T-PG Light gray pendant-mount back box (CE, UL, cUL) BB5T-PG-E Same as BB5T-PG e.
Pelco Manual C1487M-D (7/99) 9 SUSPENDED CEILING 1. Remove the ceiling tile from the ceiling. (The ceiling tile cannot be thinner than 0.50 inch [1.27 cm] nor thicker than 1.75 inches [4.45 cm].) 2. Locate the center point to drill a hole in the tile.
10 Pelco Manual C1487M-D (7/99) WIRING Bring wiring to the back box opening in the ceiling. Do not attach the wiring to the back box. Y ou will do that later . Refer to Figure 8 for the Spectra II™ wiring diagram or Figure 9 for the Spectra Lite™ wiring diagram.
Pelco Manual C1487M-D (7/99) 11 Figure 9. Wiring Diagram for Spectra Lite™ CONTROL (RS-422) SPECTRA LITE™ INTERCONNECT BOARD If you are using a Coaxitron ® controller , the control signals to operate the dome drive will be transmitted over the video coax.
12 Pelco Manual C1487M-D (7/99) T able B. 24 V AC Wiring Distances The following are the recommended maximum distances for 24 V AC with a 10-percent voltage drop.
Pelco Manual C1487M-D (7/99) 13 BACK BOX CONNECTIONS Refer to Figure 12 or 13 to attach the wiring to the interconnect circuit board inside the back box. Also refer to Figure 8 or 9 if necessary . 1. Ear th Gr ound - Connect earth ground to the middle connector on the power connector .
14 Pelco Manual C1487M-D (7/99) Figure 13. Interconnect Circuit Board Electrical Connections for Spectra Lite™ HTR/F AN RX– RX+ TX– TX+ PWR IN FUSE 1.6 A DOME DRIVE CONNECTOR RS-422 CONTROL SIGNALS POWER (24 V AC ONL Y) FA N 24 V AC MIDDLE PIN IS GND VIDEO CONNECTOR FOR OPTIONAL TRANSLA TOR SUBASSEMBL Y 5.
Pelco Manual C1487M-D (7/99) 15 DOME DRIVE 1. T urn on power to the back box. The red LED should light to indicate power. If the LED does not light, correct the trouble before proceeding.
16 Pelco Manual C1487M-D (7/99) T able D. Switch Settings for SW2 – P-T ype Control NOTES: For Coaxitron ® controls, SW2 is not used; set all switches OFF .
Pelco Manual C1487M-D (7/99) 17 T able E. Switch Settings for SW2 – D-T ype Control NOTES: For Coaxitron ® controls, SW2 is not used; set all switches OFF .
18 Pelco Manual C1487M-D (7/99) T able E. Switch Settings for SW2 – D-Type Control (continued) Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 57 ON OFF OFF ON ON ON .
Pelco Manual C1487M-D (7/99) 19 T able E. Switch Settings for SW2 – D-T ype Control (continued) Continued on next page 1 17 ON OFF ON OFF ON ON ON OFF 1 18 OFF ON ON OFF ON ON ON OFF 1 19 ON ON ON O.
20 Pelco Manual C1487M-D (7/99) T able E. Switch Settings for SW2 - D-T ype Control (continued) Continued on next page 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ON ON OFF OFF.
Pelco Manual C1487M-D (7/99) 21 T able E. Switch Settings for SW2 - D-T ype Control (continued) 237 ON OFF ON ON OFF ON ON ON 238 OFF ON ON ON OFF ON ON ON 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF.
22 Pelco Manual C1487M-D (7/99) INST ALLA TION FOR PENDANT MODELS PENDANT -MOUNT INST ALLA TION 1. Install the pendant dome mount. Refer to the instructions supplied with the mount. If the mount is outdoors, make sure it is properly sealed to keep moisture out.
Pelco Manual C1487M-D (7/99) 23 10. If you are installing an outdoor model, plug the two-pin heater connection in the lower dome into the mating connector in the back box. 1 1. Remove the two screws and the tube of Loctite ® from the parts bag. Apply a drop of Loctite ® to each screw .
24 Pelco Manual C1487M-D (7/99) POWER-UP DISPLA Y When the Spectra II™ dome or Spectra Lite™ dome is powered up or reset, the selected protocol, revision number , and other information is displayed on the monitor . For example, the screen might show the following information: PELCO SPECT II 4.
Pelco Manual C1487M-D (7/99) 25 ZOOM SPECTRA II™ ZOOM The Spectra II™ dome can magnify an object up to 128 times. The dome has 16X of optical zoom and 8X of electronic (digital) zoom for 128X total zoom. The amount of zoom can be set for 16X, 32X, 64X, or 128X.
26 Pelco Manual C1487M-D (7/99) RANDOM, FRAME, AND AUTO SCANNING Program preset 97 (30) to start random scanning. Program preset 98 (31) to activate frame scanning (three seconds of scanning followed by a three-second pause). Program preset 99 (32) to start auto (continuous) scanning.
Pelco Manual C1487M-D (7/99) 27 In certain situations, the dome will respond as follows: • If a preset has not been set, but an alarm is connected: the dome will go to a factory preset that will not be the desired position. • If one alarm is a preset and another is a pattern and both are received: the dome will alternate between them.
28 Pelco Manual C1487M-D (7/99) PROGRAMMING THE SPECTRA II™ AND SPECTRA LITE™ The Spectra II™ and Spectra Lite™ domes can be programmed for the following functions.
Pelco Manual C1487M-D (7/99) 29 MAIN MENU ACCESS Y ou can call up the main menu on your monitor by programming (setting or creating) preset 95 (28 if in 32-preset mode; refer to the Preset Functions section). Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using.
30 Pelco Manual C1487M-D (7/99) 3. Press the Iris Open button to enter the Camera submenu. 4. Move the joystick up or down to position the cursor beside Backlight Comp. 5. Press the Iris Open button on your keyboard. A star will appear beside Backlight Comp and the cursor will move to the right beside the word On or Off.
Pelco Manual C1487M-D (7/99) 31 T urning off power to the Spectra II™ and Spectra Lite™ domes does not reset the camera. Camera settings are retained in memory , and when the power is turned back on, the settings will be the same as they were when it was turned off.
32 Pelco Manual C1487M-D (7/99) Gain The gain adjusts the signal level of the video output. Increasing the gain in low light conditions will increase the level of noise in the picture.
Pelco Manual C1487M-D (7/99) 33 PEAK - (Spectra II only) The cursor moves to a numeric value. Increasing this value will cause the auto iris circuit to react more to highlights or “peaks” in the picture. Decreas- ing this value will cause it to use the average video level to adjust the iris.
34 Pelco Manual C1487M-D (7/99) AUTO-FOCUS MODE There are two auto-focus modes: auto and off. If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will place the focus in the manual mode. The dome will return to auto focus if you pan or tilt the unit or do a zoom function.
Pelco Manual C1487M-D (7/99) 35 AUTO SHARPNESS - (Spectra II only) The cursor moves to one of two choices: On or Of f. Move the joystick up or down to toggle between them. Press the Iris Open button to select the choice, or press the Iris Close button if you do not want to change the setting.
36 Pelco Manual C1487M-D (7/99) T o change the line synchronization settings: 1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section). The main menu will appear .
Pelco Manual C1487M-D (7/99) 37 T o select the power-up mode: 1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section).
38 Pelco Manual C1487M-D (7/99) 5. Press the Iris Open button. The cursor will move to the right beside the word On or Off. 6. Move the joystick up or down to toggle between On or Off. 7. SELECT - Press the Iris Open button on your keyboard to select your choice.
Pelco Manual C1487M-D (7/99) 39 ALARM PA TTERN (This section applies to Spectra II™ only .) In response to an alarm, the Spectra II™ dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3 minutes long).
40 Pelco Manual C1487M-D (7/99) AUTO FLIP There are two auto flip modes: on or off. When the auto flip mode is on, the auto flip feature is enabled. When it is off, the feature is disabled.
Pelco Manual C1487M-D (7/99) 41 LIMIT STOPS There are two types of limit stops: Manual limit stops Scan limit stops When manual limit stops are set, a manual (joystick) pan operation will stop when a limit stop is reached.
42 Pelco Manual C1487M-D (7/99) PARK TIME MINUTES This feature causes the dome to park at preset 1 after a programmed number of minutes of control inactivity . The time can be set from 1 minute to 720 minutes (12 hours), or it can be set to zero, which disables this feature.
Pelco Manual C1487M-D (7/99) 43 3. Press the Iris Open button to enter the submenu entitled Other . 4. Move the joystick up or down to position the cursor beside Pattern Length. 5. Press the Iris Open button. The cursor will move to the right beside the number of minutes (1.
44 Pelco Manual C1487M-D (7/99) d. T urn on power. If the unit still does not operate, turn off power and replace the dome drive with a unit that is good, if you have a spare. Check the switch settings on the substitute dome drive before installing it.
Pelco Manual C1487M-D (7/99) 45 BACK BOX ELECTRONIC ASSEMBL Y REMOV AL T o remove the back box electronic assembly: 1. T urn of f power . 2. Open the interconnect door and disconnect all wiring to the back box. 3. Use an 1 1/32 socket driver to remove the three 8-32 washers and nuts that hold the electronic assembly to the back box.
46 Pelco Manual C1487M-D (7/99) SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .
Pelco Manual C1487M-D (7/99) 47 Ratings: NEMA Type 1–In-ceiling back boxes, all dome drives NEMA Type 4–Pendant back boxes IP 66–Pendant back boxes Weight Unit Shipping In-Ceiling Back Box: 2.6 lb (1.18 kg) 4 lb (1.81 kg) Dome Drive: 2.65 lb (1.
48 Pelco Manual C1487M-D (7/99) Effective Pixels (NTSC Spectra II™): 768 (H) x 494 (V) (PAL Spectra II™): 752 (H) x 582 (V) (NTSC Spectra Lite™): 510 (H) x 492 (V) (PAL Spectra Lite™): 500 (H) x 582 (V) Horizontal Resolution (Spectra II™): >450 TV lines (Spectra Lite™): 350 TV lines Lens Minimum f-stop (Spectra II™): F1.
Pelco Manual C1487M-D (7/99) 49 MONOCHROME (Spectra II™ Only) Signal Format EIA (model DD5AM) CCIR (model DD5AM-X) Scanning System: 2:1 interlace Image Sensor 1/4-inch interline transfer CCD Horizontal Resolution: >500 TV lines Effective Pixels EIA: 768 (H) x 494 (V) CCIR: 752 (H) x 582 (V) Lens: Minimum f-stop: F1.
50 Pelco Manual C1487M-D (7/99) REVISION HISTOR Y Manual # Date Comments C1487M 7/98 Original version. C1487M-A 11/98 Revised the manual to incorporate Spectra Lite™ material. Added material on CCIR and EIA monochrome cameras, and P AL color camera.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco C1487M-D è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco C1487M-D - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco C1487M-D imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco C1487M-D ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco C1487M-D, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco C1487M-D.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco C1487M-D. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco C1487M-D insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.