Manuale d’uso / di manutenzione del prodotto C1456M-D del fabbricante Pelco
Vai alla pagina of 58
SD5 Series Spectra ® (Softwar e V ersion 3.0) Dome Installation/ Operation Manual C1456M-D (10/98) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.
2 Pelco Manual C1456M-D (10/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 7 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS ............................... 7 1.2 REGULA TOR Y NOTICES .
Pelco Manual C1456M-D (10/98) 3 5.1 1.17 Alarm Pattern ...................................................................... 46 5.11.18 Zone Blank ......................................................................... 46 5.11.19 Auto Flip ........
4 Pelco Manual C1456M-D (10/98) REVISION HISTOR Y Manual # Date Comments C1456M 3/97 Original version. 4/97 Added instructions for assembling T-rail clip for metal panel per ECO 97-134. C1456M-A 4/97 Revision A. Added pendant models. 5/97 Added standard heater and sun shield.
Pelco Manual C1456M-D (10/98) 5 C1456M-D 8/98 Manual name changed to Spectra ® (Software V ersion 3.0). In Section 2.2, revised the certifications. In Section 5.1, added information about selectable power-up mode. In Section 5.2, revised information about high zoom in turbo mode.
6 Pelco Manual C1456M-D (10/98) (This page intentionally left blank.).
Pelco Manual C1456M-D (10/98) 7 1.1 IMPORT ANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
8 Pelco Manual C1456M-D (10/98) 1.2 REGUL A TO R Y NOTICES NOTE : This equipment has been tested and found to comply with the limits of a Clas s A digital device, pursuant to part 15 of the FCC rules.
Pelco Manual C1456M-D (10/98) 9 COMPASS TOOL SAFETY BRACKET CONDUIT FITTING & LOCK NUT T -RAIL CLIP Figure 2. Back Box Parts Figure 1. In-Ceiling Components BACK BOX DOME DRIVE LOWER DOME 1.
10 Pelco Manual C1456M-D (10/98) Figure 3. Pendant Components BACK BOX DOME DRIVE LOWER DOME 1.3.2 Pendant Models The Spectra ® (V ersion 3.0) dome shipping carton contains three boxes, plus the C1456M-D system manual that covers everything in the system (back box, dome drive, and lower dome).
Pelco Manual C1456M-D (10/98) 11 1.4 RECOMMENDED TOOLS Pelco does not supply basic tools needed for the installation process. The following tools are recommended.
12 Pelco Manual C1456M-D (10/98) 2.0 DESCRIPTION Spectra ® (V ersion 3.0) domes are capable of the following: • 360 ° pan rotation • preset positioning • +2 to -92 ° tilt • variable speed The in-ceiling models can be installed in hard ceilings or standard 2' x 2' (61 cm x 61 cm) suspended ceilings.
Pelco Manual C1456M-D (10/98) 13 2.2 CERTIFICA TIONS The products identified below have been tested and certified for agency compli- ance as noted. Agency Compliance Certification Model CE FCC UL CSA/cUL Spectra ® (V er . 3) DD5-C-X X Spectra ® (V er .
14 Pelco Manual C1456M-D (10/98) Figure 4. Compass T ool Figure 5. Conduit Fitting Installation A TT ACH SAFETY CHAIN HERE CAUTION: Be careful not to cut outside of the line. If you do, you may not be able to install the back box. Also, the trim ring may not cover the hole.
Pelco Manual C1456M-D (10/98) 15 CAUTION: The ceiling tile must be capable of supporting 16 pounds (7.3 kg) of weight. If the ceiling tile will not support this weight, order the SD5-P metal panel. CAUTION: Be careful not to cut outside of the line. If you do, you may not be able to install the back box.
16 Pelco Manual C1456M-D (10/98) Figure 8. Wiring Diagram NOTE: The dome will stop oper- ating if the voltage at the dome drops below 18 V AC. It will turn back on when the voltage exceeds 18 V AC. 3.2 WIRING Bring wiring to the back box opening in the ceiling.
Pelco Manual C1456M-D (10/98) 17 T able A. V ideo Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor .
18 Pelco Manual C1456M-D (10/98) OPTIONAL PROCEDURE: If you prefer , you may make the wir - ing connections inside the back box before installing the back box in the ceiling. T o do this, loosen the thumbscrew inside the back box and open the hinged door (refer to Figure 9).
Pelco Manual C1456M-D (10/98) 19 Figure 11. Interconnect Circuit Board Electrical Connections Figure 10. Transformer Wiring EXAMPLE: If each dome requires 20 vA, three domes require a 60 vA transformer.
20 Pelco Manual C1456M-D (10/98) NOTE: Connect only a low volt- age device to the relay output. Maximum current rating of the re- lay contacts is two amperes. CAUTION: The maxi- mum output of AUX 2 is 150 mA. If you connect a device that draws more current, you could destroy the output transistor .
Pelco Manual C1456M-D (10/98) 21 T able C. Switch Settings for SW1 Control T ype Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 Coaxitron ® OFF OFF OFF OFF OFF OFF OFF OFF** P-T ype Control ON OFF OFF OFF OFF OFF OFF OFF** D-T ype Control OFF ON OFF OFF OFF OFF OFF* OFF** NOTES: Switches SW1-3 through SW1-6 MUST be OFF .
22 Pelco Manual C1456M-D (10/98) T able D. Switch Settings for SW2 – P-Type Control NOTES: For Coaxitron ® controls, all switches on SW2 MUST be OFF .
Pelco Manual C1456M-D (10/98) 23 T able E. Switch Settings for SW2 – D-Type Control NOTES: For Coaxitron ® controls, all switches on SW2 MUST be OFF .
24 Pelco Manual C1456M-D (10/98) T able E. Switch Settings for SW2 – D-T ype Control (continued) Receiver Address Switch Setting SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 57 ON OFF OFF ON ON O.
Pelco Manual C1456M-D (10/98) 25 T able E. Switch Settings for SW2 – D-T ype Control (continued) Continued on next page 117 ON OFF ON OFF ON ON ON OFF 118 OFF ON ON OFF ON ON ON OFF 119 ON ON ON OFF.
26 Pelco Manual C1456M-D (10/98) T able E. Switch Settings for SW2 - D-T ype Control (continued) Continued on next page 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ON ON OFF OF.
Pelco Manual C1456M-D (10/98) 27 T able E. Switch Settings for SW2 - D-T ype Control (continued) 237 ON OFF ON ON OFF ON ON ON 238 OFF ON ON ON OFF ON ON ON 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OF.
28 Pelco Manual C1456M-D (10/98) Figure 14. Lower Dome Installation, Pendant Models NOTE: If outdoors, apply Duct Seal inside the pipe portion of the back box to prevent moisture or cold air inside the mount from en- tering the unit and causing conden- sation on the dome.
Pelco Manual C1456M-D (10/98) 29 NOTE: For hard ceilings, such as concrete, where the wiring must be installed in surface-mounted con- duit, use the optional BB5-PCA-BK (black) or BB5-PCA-GY (gray) Pen- dant Conduit Adapter . 9. Look inside the lower dome and note which of the six retainer screws is clos- est to your finger .
30 Pelco Manual C1456M-D (10/98) 5.0 OPERA TION The red LED in the interconnect door in the back box lights when power is turned on and the fan operates to exhaust heat from inside the back box. If you have an outdoor pendant model with a heater , the heater elements in the back box turn on at 70 ° F (21 ° C) and turn off at 85 ° F (29 ° C).
Pelco Manual C1456M-D (10/98) 31 5.2.1 Auto Flip When the camera tilts downward and goes just beyond the vertical position, the dome rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as long as you continue to hold the joystick in the down position.
32 Pelco Manual C1456M-D (10/98) 5.5 RANDOM, FRAME, AND AUTO SCANNING Program preset 97 (30) to start random scanning. Program preset 98 (31) to acti- vate frame scanning (three seconds of scanning followed by a three-second pause). Program preset 99 (32) to start auto (continuous) scanning.
Pelco Manual C1456M-D (10/98) 33 In certain situations, the dome will respond as follows: • If a preset has not been set, but an alarm is connected: the dome will go to a factory preset that will not be the desired position. • If one alarm is a preset and another is a pattern and both are received: the dome will alternate between them.
34 Pelco Manual C1456M-D (10/98) 5.11 PROGRAMMING THE SPECTRA™ (VERSION 3.0) The Spectra ® (V ersion 3.0) dome can be programmed for the following functions: AGC (automatic gain control) Auto park .
Pelco Manual C1456M-D (10/98) 35 5.11.1 Main Menu Access Y ou can call up the main menu on your monitor by programming (setting or creat- ing) preset 95 (28 if in 32-preset mode; refer to Section 5.4). Programming preset 95 varies according to the type of controller you are using.
36 Pelco Manual C1456M-D (10/98) 5.11.2 Backlight Compensation There are two backlight compensation modes: on and off. Backlight compensation allows the Spectra ® (V ersion 3.0) dome to compensate for bright light behind the object you want to view .
Pelco Manual C1456M-D (10/98) 37 5.11.4 Reset Camera Resetting the camera returns the following settings to their defaults. Setting: Default: Auto-focus mode Auto Gain/AGC AGC mode Auto Gain No defaul.
38 Pelco Manual C1456M-D (10/98) 5.11.5 Gain/AGC 5.11.5.1 AGC Mode There are three AGC (Automatic Gain Control) modes: auto, on, and of f. In the auto mode, the Spectra ® (V ersion 3.
Pelco Manual C1456M-D (10/98) 39 5.11.6 Auto Iris There are three settings for auto iris: mode, level, and peak. T o change the settings for auto iris: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNCTIONS) to access the main menu (refer to Section 5.
40 Pelco Manual C1456M-D (10/98) 5.11.7 Shutter Speed There are nine electronic shutter speed settings: Auto 1/100 1/120 1/500 1/1000 1/2000 1/4000 1/10,000 1/30,000 In the Auto setting the camera controls the shutter speed automatically.
Pelco Manual C1456M-D (10/98) 41 5.11.8 Auto-Focus Mode There are two auto-focus modes: auto and of f. If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will place the focus in the manual mode. The dome will return to auto focus if you pan or tilt the unit or do a zoom function.
42 Pelco Manual C1456M-D (10/98) 5.11.10 White Balance (Color Cameras Only) There are three settings for white balance: auto, red-blue, and magenta-green. T o change the white balance settings: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.
Pelco Manual C1456M-D (10/98) 43 5.11.11 Line Synchronization Y ou can turn the line synchronization on or of f. If it is on, you can adjust the synchronization of the power line voltage so that it is in phase with other cameras.
44 Pelco Manual C1456M-D (10/98) T o select the power-up mode: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4,PRESET FUNCTIONS) to access the main menu (refer to Section 5.
Pelco Manual C1456M-D (10/98) 45 5.11.15 Alarm Dwell This is the minimum time the Spectra ® (V ersion 3.0) will stay at an alarm even if the alarm is present for less than this amount of time. T o change the alarm dwell: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.
46 Pelco Manual C1456M-D (10/98) 5.11.17 Alarm Patter n In response to an alarm, the Spectra ® (Version 3.0) dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.
Pelco Manual C1456M-D (10/98) 47 5.11.19 Auto Flip There are two auto flip modes: on or of f. When the auto flip mode is on, the auto flip feature is enabled. When it is off, the feature is disabled. T o change the auto flip mode: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.
48 Pelco Manual C1456M-D (10/98) 5.11.21 Limit Stops There are two types of limit stops: Manual limit stops Scan limit stops When manual limit stops are set, a manual (joystick) pan operation will stop when a limit stop is reached.
Pelco Manual C1456M-D (10/98) 49 5.11.22 Park Time Minutes This feature causes the dome to park at preset 1 after a programmed number of minutes of control inactivity . The time can be set from 1 minute to 720 minutes (12 hours), or it can be set to zero, which disables this feature.
50 Pelco Manual C1456M-D (10/98) 5.11.24 Pattern Length Y ou can set the pattern length to 1.5, 3, or 6 minutes or have two half-patterns of .75, 1.5, or 3 minutes long. T o set the pattern length: 1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.
Pelco Manual C1456M-D (10/98) 51 6.0 TROUBLESHOOTING Symptom: Unit does not operate. 1. Make sure your controller is trying to communicate with the unit and not an- other camera.
52 Pelco Manual C1456M-D (10/98) Symptom: Fan does not operate. 1. T urn off power . 2. Remove the lower dome: In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on the trim ring and twist the screwdriver to pop loose the trim ring and lower dome.
Pelco Manual C1456M-D (10/98) 53 7.0 MAINTENANCE 7.1 DOME CLEANING Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the sufaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic.
54 Pelco Manual C1456M-D (10/98) 8.0 SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .
Pelco Manual C1456M-D (10/98) 55 ELECTRICAL Input Voltage: 18-30 VAC, 24 VAC nominal Input Power In-ceiling: 25 vA Indoor pendant: 25 vA Outdoor pendant: 90 vA Fuse: 1.
56 Pelco Manual C1456M-D (10/98) BLACK AND WHITE Signal Format: EIA/CCIR Scanning System: 2:1 interlace Image Sensor 1/4-inch interline transfer EIA: Total pixels: 537 (H) x 505 (V) Effective pixels: 510 (H) x 492 (V) CCIR: Total pixels: 537 (H) x 597 (V) Effective pixels: 500 (H) x 582 (V) Resolution: 380 TV lines Lens Minimum f/stop: F/1.
Pelco Manual C1456M-D (10/98) 57 NOTES.
58 Pelco Manual C1456M-D (10/98) 9.0 W ARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 1998, Pelco. All rights reserved.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco C1456M-D è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco C1456M-D - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco C1456M-D imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco C1456M-D ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco C1456M-D, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco C1456M-D.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco C1456M-D. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco C1456M-D insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.