TECHNICAL & SER VICE MANU AL CZ-RD515U WIRED REMO TE CONTROLLER REFERENCE NO . SM 700883 Model No. CZ-RD515U Product Code No. 1 852 361 14.
• Before doing repair work, please read the " SAFETY PRECA UTIONS" carefully and fully understand them. • The precautionary items here are divided into " W arning" and " Caution" items.
W arning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle.
T able of Contents SAFETY PRECA UTIONS T ABLE OF CONTENTS 1. SPECIFICA TIONS 2. APPLICABLE INDOOR UNITS 3. FUNCTIONS 4. SELF-DIA GNOSTICS 4-1. Self-Diagnostics Procedure 4-2. Self-Diagnostics T able (Ceiling Cassette T ype) 4-3. Self-Diagnostics T able (W all Mounted T ype 1) 4-4.
1. SPECIFICATIONS 70.0 16.5 120.0 Item Signal Transmission Method Dedicated Remote Controller Cable DC5V supplied from Indoor Unit Liquid Crystal Set Temperature Indication (68 °F to 86 °F) Six Dire.
2. APPLICABLE INDOOR UNITS 3. FUNCTIONS When the unit is modified from one for wireless remote controller to that for wired remote controller, the following functions become unavailable.
4. SELF-DIA GNOSTICS PROCEDURE After turning on power to the air conditioner, use the remote controller and follow the steps below to execute self-diagnostics. Step 1: Press and hold the remote controller NIGHT SET BACK (NSB) button and 1 HR TIMER button.
4-2. Self-Diagnostics T able (Ceiling Cassette T ype) Since the indications cover various units, the corresponding parts listed below may not be present in some models.
4-3. Self-Diagnostics T able (W all Mounted T ype 1) REMOTE CONTROL receiver (1) OPERATION lamp (2) TIMER lamp (3) QUIET lamp OPERATION button INDOOR UNIT Since the indications cov er v arious units, the corresponding par ts listed below ma y not be present in some models.
4-4. Self-Diagnostics T able (W all Mounted T ype 2) (1) OPERATION lamp (2) TIMER lamp (3) OPERATION TIMER ON/OFF INDOOR UNIT Since the indications cov er v arious units, the corresponding par ts listed below ma y not be present in some models. INDICA TION ON INDOOR UNIT .
.
Operating Instructions CZ-RD515U (852-6-4181-230-00-1) APPENDIX A A-1.
Wired Remote Controller Model No. CZ-RD515U Operating Instructions Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan 85264181230001 CV6233187877 This wired remote controller is designed for both the “COOL/DRY/HEAT Model” and “COOL/DRY Model” indoor unit.
2 FEA TURES • Micropr ocessor Co ntr olled Operation The interior comp ar tment of the remote controll er contains se v eral f eatures to facil itate automatic op eration, easy logicall y displa yed f or easy use. • 24-Hour ON or OFF Timer This timer can be set to automatically turn the unit on or off at any time within a 24 hour period.
3 INST ALLA TION LOCA TION W e recommend that this wired remote controller be installed proper ly b y qualified installation tec hnicians in accor dance with the Installa tion Instructions pro vided with the unit.
4 REMO TE CONTR OLLER Display Inf ormation on the operating condition s is displa yed while the remote controller is s witched on. If the unit is turned off, only the mode that w as set previously is still displayed. F AN SPEED selector button : The air conditioner automatically dec ides the fan spe eds.
5 Sensor A temperature sensor inside the remote controller senses the room temperature . ON/OFF operation b utton This bu tton is f or turning the air conditioner on and off .
6 REMO TE CONTR OLLER (DISPLA Y) (1) Operation mod e A UT O ................. ................... . (only f or COOL/DR Y/HEA T Model) HEA T .................. ................ .... (only f or COOL/DR Y/HEA T Model) MILD DR Y .......... ...............
7 OPERA TION WITH THE REMO TE CONTR OLLER 1. A utomatic Operation (only f or COOL/DR Y/HEA T Model) • Single use This unit automatically s witches betw een cooling operati on and heating operatio n according to the diff erence between the room temperature and the t emperature setting.
8 3. Adjusting the Fan Speed A. A utomatic fan speed Simply set the F AN SPEED selector b utton to the position. This automatically sets th e best fan speed for the room temperature. B. Manual fa n speed If you w ant to adjust fan speed manually during operation, just set the F AN SPEED selector button as desired.
9 SETTING THE TIMER 1. How to set the p resent time (Example) T o set to 9:10 pm. 2. How to set the OFF time (Example) T o stop the air conditioner at 11:30 pm. T o cancel the setting, press the TIMER SELECT button twice. 3. How to set the ON time (Example) T o star t operation at 7:10 am.
10 USING THE 1-HOUR OFF TIMER 1. 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regar dless of whether the unit is on or off when this button is pressed. The indicator in the displa y i ndicates that this function is operating.
.
A-2 INSTALLATION INSTRUCTIONS (CZ-RD515U) CZ-RD515U (852-6-4190-592-00-0) APPENDIX B.
Parts supplied with the remote controller See T able 1. Remote controller installation guidelines Mount the remote controller 3.3 to 4.9 ft. (1 to 1.
2 A. Installing with in-wall junction box (1) Install the junction box (locally purchased) into the wall. (Figs. 2-a and 3) (2) Pass the wire harness through the junction box and conduit. (Fig. 3) (3) Insert a flathead screwdriver into the 5 tab locations and disconnect the back plate of the remote controller by lifting up slightly .
Fig. 8 Indicator Wire harness Ceiling panel T erminal cover Clamps 7P IND and 4P RC wiring connector 5P FLAP wiring connector Clamping strap FLAP RC IND 7P 4P 5P FLAP wiring connector Wire harness Rem.
4 Fig. 9 Fig. 10 Fig. 1 1 ON/OFF operation button 1 HR.TIMER button NIGHT SETBACK button ACL (Reset) button SENSOR button OPERA TION lamp TIMER lamp HIGH POWER lamp REMOTE CONTROL receiver OPERA TION .
.
A-3 CZ-RC515U (852-6-4190-590-00-0) APPENDIX C INSTALLATION INSTRUCTIONS Installing the Connection Kit for Wall-Mounted Models ().
Installing the connection kit A. 7000 BTU, 9000 BTU, and 12000 BTU inverter models (1) Remove the air intake grille. (2) Remove the terminal cover . Pull out the thermistor , then remove the grille. For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package.
(10) Pass the wire tube through the clamping strap, and temporarily fasten in place with the screw . Next, use a clamp and bind the wires together immediately above the clamping strap, and fasten in place with the screw in order to prevent pulling on the wire harness.
3 B. 18000 BTU and 24000 BTU inverter models (1) Remove the air intake grille. (2) Remove the terminal cover . Pull out the thermistor , then remove the grille. For details on steps (1) and (2), refer to the Installation Instructions included in the outdoor unit package.
4 Fig. 9 Fig. 10 Fig. 1 1 ON/OFF operation button 1 HR.TIMER button NIGHT SETBACK button ACL (Reset) button SENSOR button OPERA TION lamp TIMER lamp QUIET lamp How to T est Run the Air Conditioner After turning on the power of the air conditioner , use the remote controller and follow the steps below to conduct the test run.
.
A-4 INSTALLATION INSTRUCTIONS Installing the Connection Kit for Wall Mounted Type 2 CZ-RC515UA (852-6-4190-591-00-0) APPENDIX D ().
Parts included in the package See T able 1. T able 1 85264190591000 201 1 CV6233187891 Connection Kit INST ALLA TION INSTRUCTIONS Parts Figure Q'ty Parts Figure Q'ty Parts Figure Q'.
2 0RYHWKHMXPSHUFDSWR:')LJWKHQFRQQHFWWKHQRLVHILOWHU&RQQHFWRU $ 3WRWKH3&%VRFNHW/$03 DQ.
3 ,QVHUWWKHQRLVHILOWHULQWRWKHHOHFWULFDOER[WKHQIDVWHQWKHQRLVHILOWHU&RQQHFWRU%ZLUHDQGWKHZLUHKDUQHVVRIWKH ZLUHGUHPRWH.
4 How to T est Run the Air Conditioner $IWHUWXUQLQJRQWKHSRZHURIWKHDLUFRQGLWLRQHU XVHWKH UHPRWHFRQWUROOHUDQGIROORZWKHVWHSVEHORZWRFRQGXFW WKH.
.
DC1111-0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Panasonic CZ-RD515U è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Panasonic CZ-RD515U - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Panasonic CZ-RD515U imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Panasonic CZ-RD515U ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Panasonic CZ-RD515U, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Panasonic CZ-RD515U.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Panasonic CZ-RD515U. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Panasonic CZ-RD515U insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.