Manuale d’uso / di manutenzione del prodotto GEM-DXRP3 del fabbricante Napco Security Technologies
Vai alla pagina of 32
1 OPERA TING GUIDE for yo ur GEM-DXRP3 KEYP AD © NAPCO 2006 OI324 11/06.
2 The GEM- DXRP3 is a “ smart ”, interac tive, menu-driven keypad d esigned for y our Napco control panel. A digital display is provided to show the sta tus of your system. This booklet contain s important information about the operation of your system with this GEM- DX RP3 Ke yp ad.
3 TABLE OF CONTENTS TABLE OF CONTENTS Section Page KEYPAD CONTROLS & INDICATOR S ... ....... ...... ...... ...... ....... ....... ..... 4 SETTING THE ALARM (ARMING) W HEN LEAVING .... ..... ...... ...... ..... 6 PRO TEC TING YO UR SEL F WHILE ON TH E PR EM ISE S .
4 96 INTERIO R BYPASS FIRE/ TBL SYS TBL CHI ME KEYPAD CONTROLS & INDIC A TORS 7 12 8 9 10 11 2 4 5 6 1 3 13.
5 KEYPAD CONTROLS & INDIC A TORS Window. Lights indicate system status m essages; digit displa y indicates related zo ne, function or error m essage number s. STATUS Light. Lights (gr een) to indicate tha t the system is re ady for a rming. If a zone is not secured, the light will be off and the zone w ill display in the window.
6 S E TT I N G T H E AL AR M ( AR M I N G ) W H E N L E AV I N G A rmin g the Sy stem 1. C heck the ke y pad. The green STATUS light m ust be on in order to arm. If the green light is off, th e number(s) of any unsecured zone(s) will display in the window.
7 S E TT I N G T H E AL AR M ( AR M I N G ) W H E N L E AV I N G System T r ouble If you attemp t to arm with the SYS TBL li ght on, a 3- seco nd tone will sound an d a “P” wil l displ ay in the w indow . Th is in dicate s tha t the sy ste m has detect ed a proble m which may preve nt it fro m operati ng p rope rly .
8 Bypassing Interi or Zones I nterio r Zones , when by passed , all ow free mo veme nt wi thin th e ho me w hile the protec tion o f ar med pe ri meter zo nes i s maintaine d. T o by pass I nteri or Z ones, pres s E and enter y our User Code follow ed by D .
9 PROTECTING YOURSELF WHILE ON TH E PREMISES Emer gency Button s (Only available if programmed) The Blue Emergency Buttons ( 7 , 8 & 9 ), if p rogrammed, are alway s active, whether the system is armed or di sarmed. The emergency signal will only be transmitted when an Emergency Button and G are pressed at the same time.
10 T UR N I N G O F F T H E AL AR M ( D I S AR M I N G ) W H E N RE T U R N I N G Disarming the Sy stem 1. Enter your premises t hrough the Entry/Exit door. The keypad w ill sound a steady tone to remind you to disarm the system before your Entry Delay time e xpires.
11 FIRE PROTECTION (Applicable only where local ordinanc e pe rmits use of this alarm cont rol panel for fire protection). Fire-Z one A larm If a f ire is detected, the FIRE/TBL light will display with the zone number and the keypad sounder will pulse.
12 FIRE PROTECTION Preparing a Fire Escape Plan Even with the most advanced fire alarm system, ad equate protection requires an e scape plan. To prepare your plan, draw floor plans of your building. (Space is prov ided on the next page). Show two exits - a front or back door and a window from each room.
13 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below. Floorplan.
14 FIRE PROTECTION Although a fire alarm system may be of a reliable and state-of- the- art design, neither it nor its peripheral detection dev ices can offer guaranteed protection against f ire.
15 KEYPAD FUNCTIONS The keypad can provide access to a w ide assortm ent of utility functions. The functions are displayed in a promptin g “YES/NO” format. 1. To enter the Functio n Menu, press A . • In all UL-listed or high-s ecurity installations, a valid User Code must first be entered follow ed by A .
16 KEYPAD FUNCTIONS 4. Display System Troubles? Displays a 1- or 2-digit error code re presenting a problem detected in the s ystem. (S ee SYSTEM TROUBLE ERROR CODES for a description of these code s). Use NEXT( E ) and PRIOR ( F ) to scroll system troubles.
17 KEYPAD FUNCTIONS 9. Re set Syst em Troub le? Sy stem tro ubles displ ay and sou nd at the keypad. Correcting the trouble will clear most indications, how ever the following error c odes will requir e manual reset: E 11; E13; E19 ; E20 a nd E22. (See SYS TEM TROUBLE E RROR COD ES fo r a d escr iption of error code s).
18 KEYPAD FUNCTIONS 15. A ctivate Telephone T est? (Telephone Te st programmed? YES NO). Sends a communicator test to t he central station. A comm unication failure will be indicated at the keypad by a system trouble “E03-00” display .
19 KEYPAD FUNCTIONS 17. Activate Program? Activates the Pro gram Mode fro m Key pa d N o. 1. Note : This feature is disabled while arm ed. (See PROGRAMMING USER CODES). 18. Activate Download? Fo r installer's use only . If accidentally enabled, press C to exit.
20 Your alarm specialist ma y have progr ammed your s ystem to be monit ored by a centra l station. The b uilt-in dig ital communicator can tran smit emergency signals and status reports to th e central station 24 hou rs a day. Communicato r Features Abort Delay .
21 A DVA NCED FEA TURES Security By pass/Unbypass (Securit y Bypass programmed? YES NO) . In high-s ecurity applications, zones may be bypassed (or unbypass ed) only if a vali d code is entered first, as follows: 1. Enter a User Code valid for bypass, then press B .
22 PROGRAMMING USER CODES Your I nstall er has prog ra mmed i nto y our sy ste m a s peci al U ser P rogr am Co de w hich can b e us ed t o not only Ar m and D isa rm th e syste m , b ut al so t o e nte r the Use r Pro gra m M ode, wh ere y ou can pro gra m ot her U s er Co des .
23 PROGRAMMING USER CODES Exiti ng the User P rogram M ode When you ha ve completed programming or erasing User Codes, press C to exit the Us er Progr am Mode. Programming Example: Example . Program the User 3 C ode to “3784”. Note: Fo r User Cod es shorte r than 6 digi ts, us e G0 for r e mainin g digits .
24 GLOSSARY Following are brief descriptions of term s and features used herein that m ay be un familiar to yo u. Some o f the f eatures are programmable options th at may or may no t apply to your particular system. Abort De lay - A delay period that allows the control panel to be reset, thus aborting a report to a central station.
25 GLOSSARY Instant Protection - Arming without entry delay using the F button wh ile remaining on the premises. INTERI OR Button - Bypasses Interior Zones on arming (see Zones - Interior Zones). Key pad - Puts control-pa nel functio ns at your fingert ips.
26 GLOSSARY Zones - Independe nt circuits that protect specific areas of the premises: • A uto-Bypass Zone : A zone that will be auto matically bypassed from the protection system if it is in trouble (faulty) when the s ystem is arm ed. • Burgla ry Zone: De tects intrusion.
27 SYSTEM TROUBLE ERROR CODES Your control pane l is capable of detecting a variety of troubles that may affect syste m performance. In the unlikely eve nt that a problem should occur, the SYS TBL (system trouble) light will display in the keypad window along with one or more of the following erro r codes .
28 SYSTEM TROUBLE ERROR CODES Trouble Indication System Trouble Condition Action E-04-NN W ire less Transmitter Super visory Failu re A pro blem h as bee n det ecte d wi th a w ireles s tra nsmit ter.
29 Trouble Indication System Trouble Condition Action E-11-NN Keypad Tamper A key pad h as be en re move d for t he wa ll. C all in stalli ng c ompa ny for se rvice if p robl em c annot be repair ed. E-12-NN Ex pansion Zone Module Response Fail ure Call in stalli ng co mpa ny for ser vice.
30 Trouble Indication Sy st em T r oubl e Condition Act ion E19-00 User Pro gr am Memo ry Err or Call installing company for service. E-20-00 Deal er Pr ogra m M emo ry E rror Call installing company for service. E-21-00 System Shutdown Call installing company for service.
31 TROUBLESHOOTING What do I do if... For more info... I try to arm my system but the keypad just displays a P and beeps at me. If the green STATUS light is off, a zone is open . Refer to the Pull Up Zone Directory and find and secure the open window or door.
32 NAPCO LIMITED WA RRANTY N APCO SE CURI TY SY STEM S, INC. (NAP CO) w arrants it s produ cts to be fr ee from m anu facturing defects in mat erials and w orkman ship for thirty -six month s following the date of man ufacture.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Napco Security Technologies GEM-DXRP3 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Napco Security Technologies GEM-DXRP3 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Napco Security Technologies GEM-DXRP3 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Napco Security Technologies GEM-DXRP3 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Napco Security Technologies GEM-DXRP3, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Napco Security Technologies GEM-DXRP3.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Napco Security Technologies GEM-DXRP3. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Napco Security Technologies GEM-DXRP3 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.