Manuale d’uso / di manutenzione del prodotto SS38 del fabbricante Monessen Hearth
Vai alla pagina of 40
Stratford .
46D0232 2 SS38 Direct V ent Gas Stove .
3 46D0232 SS38 Direct V ent Gas Stove 4. Never install the stove • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the stove • in high traffic areas • in windy or drafty areas 5.
46D0232 4 SS38 Direct V ent Gas Stove 12. Do not use this stove to cook food or burn paper or other objects. 13. Never place anything on top of stove. 14. Do not use any solid fuels (wood, coal, paper , card- board, etc.
5 46D0232 SS38 Direct V ent Gas Stove • This appliance has been certified for use with either natural or propane gas. See appropriate data plates.
46D0232 6 SS38 Direct V ent Gas Stove If this unit is installed in a mobile home it must be bolted securely to the floor with leg bolts. Stratford SS38 model stove works without any electrical supply .
7 46D0232 SS38 Direct V ent Gas Stove Figure 3 - T ypical Installations ST1100 stov e locations ST1 100 Plan for the installation of your stove.
46D0232 8 SS38 Direct V ent Gas Stove Maintain the following minimum clearances for service and maintenance. • Stove must be at least 6" from the back wall.
9 46D0232 SS38 Direct V ent Gas Stove .
46D0232 10 SS38 Direct V ent Gas Stove When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Insulation should be considered a combustible material.
1 1 46D0232 SS38 Direct V ent Gas Stove V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA.
46D0232 12 SS38 Direct V ent Gas Stove .
13 46D0232 SS38 Direct V ent Gas Stove 1. Determine the route your horizontal venting will take.
46D0232 14 SS38 Direct V ent Gas Stove 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the cent er of the 7 Zx " (190 mm) or 9 Zx " (24 1 mm) hole on the exterior wall with the word “UP” on the vent cap facing up.
15 46D0232 SS38 Direct V ent Gas Stove Figures 15 through 17 show different configurations for venting with horizontal termination.
46D0232 16 SS38 Direct V ent Gas Stove 1. Determine the route your vertical venting will take. If ceilin g joist, roof rafters or other framing will obstruc t the venting system, consider an offset.
17 46D0232 SS38 Direct V ent Gas Stove 1.
46D0232 18 SS38 Direct V ent Gas Stove Figures 23 through 26 show four dif ferent configurations for vertical termination. Y ou must install a restrictor on all vertical installations.
19 46D0232 SS38 Direct V ent Gas Stove H V H 1 ST1111 vert vent 2 elbows Figure 24 - V ertical Rigid Venting Configuration Using Three 90° Elbows with T wo Horizontal Runs Install restrictor into 4" collar of stove or first vent secton as shown.
46D0232 20 SS38 Direct V ent Gas Stove FP1977 external regulator Use proper gas type for the stove you are installing. If you have conflicting gas type, do not install stove. See dealer where you purchased the stove for proper stove for your gas type or conversion kit.
21 46D0232 SS38 Direct V ent Gas Stove .
46D0232 22 SS38 Direct V ent Gas Stove 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the stove, Do not install the appliance. Contact your dealer immediately .
23 46D0232 SS38 Direct V ent Gas Stove This stove will work without any electrical supply . Electricity is only needed to operate blower .
46D0232 24 SS38 Direct V ent Gas Stove L G736 VS38 left base log 1. Carefully remove logs from wrapping.
25 46D0232 SS38 Direct V ent Gas Stove L G737 VS38 right base log Figure 34 - Install Right Base Log Right Base Log LG737 5. P lace right base log on two pins against right side of firebox. Figure 34.
46D0232 26 SS38 Direct V ent Gas Stove L G741 VS38 embers L G740 VS38 top center log Figure 37 - Install T op Center Log Leave Air Space between Logs and Rock Wool Rock Wool Figure 38 - Install Rock Wool T op Center Log Embers Pins 8.
27 46D0232 SS38 Direct V ent Gas Stove This appliance is equipped with a pilot which must be lit with built-in battery ignitor while following these instructions exactly . BEFORE OPERA TING smell all around the appliance area for gas.
46D0232 28 SS38 Direct V ent Gas Stove PILOT O F F P I L O T O N FP1935 control knob pilot .
29 46D0232 SS38 Direct V ent Gas Stove PILOT O F F P I L O T O N O F F P I L O T O N PILOT FP1937 control knob on Figure 41 - On Pos.
Make sure the gas valve knob is in the “OFF” position. W ait at least five (5) minutes before start-ing maintenance. A qualified agency should examine the venting system annu- ally . Clean the ceramic glass periodically .
31 46D0232 SS38 Direct V ent Gas Stove ST1115 air shutter open The venturi of the burner is equipped with an air shutter .
46D0232 32 SS38 Direct V ent Gas Stove ST1117 VS38 replace glass 1. Put on gloves. Remove door from hinges by lifting the door up. Figure 48 2 . Remove the 7/8" rope from around glass frame. Figure 49 3.
33 46D0232 SS38 Direct V ent Gas Stove ST1118 blower White (Hi T emp) ST1119 VS38 w.
46D0232 34 SS38 Direct V ent Gas Stove Spark ignitor will not light the pilot after repeated pressing of spark ignitor . Pilot will not stay lit. Burner will not light when valve and burner switch are both on.
35 46D0232 SS38 Direct V ent Gas Stove 1 4 17 9 14 13 6 15 16 19 7 10 5 1 1 12 2 21 24 22 3 18 AA Battery 25 23 20 8 2030245 VS38 par ts.
46D0232 36 SS38 Direct V ent Gas Stove .
37 46D0232 SS38 Direct V ent Gas Stove 7" x 48" Pipe 902B 7" x 36&qu.
46D0232 38 SS38 Direct V ent Gas Stove This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
39 46D0232 SS38 Direct V ent Gas Stove MHSC warrants its products to be free of defects in material and workmanship and backs each product with a Limited Lifetime W arranty . This warranty is to the original purchaser of a MHSC product and is not transferable.
149 Cleveland Drive • Paris, Kentucky 40361 www .mhsc.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Monessen Hearth SS38 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Monessen Hearth SS38 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Monessen Hearth SS38 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Monessen Hearth SS38 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Monessen Hearth SS38, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Monessen Hearth SS38.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Monessen Hearth SS38. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Monessen Hearth SS38 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.