Manuale d’uso / di manutenzione del prodotto 3300 del fabbricante Mitel
Vai alla pagina of 22
7/4/2004 Page 1 of 22 Mitel PBX interface with Conferencing Server Configuration Notes Note: This document section is maintained by Mitel Networks When referring to any information in this document please also check the Additions & Correction section on the last page for up dates.
7/4/2004 Page 2 of 22 Mitel PBX interface with Conferencing Server Configuration Notes Mitel PBX interface with Confere ncing Server Configuration Notes ........................ 1 Introduction ..........................................................
7/4/2004 Page 3 of 22 Introduction This document describes the configuration of Mitel Networks PBX’s to correctly interface to the Interactive Group Communication System by VCon. For more information on the configuration o f the IGC, please refer to Mitel 3300 - RemoteAbility IGC Integration Specifications V1 .
7/4/2004 Page 4 of 22 ANI/DNIS/ISDN Number Delivery Yes Link Descriptor Assignment Number: 4 Address for Message Control: A BER - Maintenance Limit, 10** - n: 4 BER - Service Limit, 10** - n: 3 Data C.
7/4/2004 Page 5 of 22 MSDN - DPNSS - DASSII Trunk Circuit Descriptor Number Card Type Dual Seizure Priority Far End Connection Signalling Protocol 4 UNIVERSAL T1 Incoming Local Office MSDN - DPNSS Tru.
7/4/2004 Page 6 of 22 • Attach VCon IGC server T1 link to NSU, DSU or Embedded PRI card o Configure hardware for Line Termination through jumpers or D IP switch – please refer to the Technician’.
7/4/2004 Page 7 of 22 ANI/DNIS/ISDN Number Delivery Yes Link Descriptor Assignment Number: 4 Address for Message Control: BER - Maintenance Limit, 10** - n: 4 BER - Service Limit, 10** - n: 3 Data Cal.
7/4/2004 Page 8 of 22 Digital E and M Trunk Circuit Descriptor Assignment Number: 4 Call Collision Han dling: AT&T AT&T Call Collision Handling: Backoff Ignore Far End Disconnect: No Release A.
7/4/2004 Page 9 of 22 D igital Trunk Assignment Cabinet: 6 Shelf: 1 Slot: 1 Circuit: 1 Card Type: UNIVERSAL T1 Trunk Number: 6101 Trunk Service Number: 4 DTS Service Number: Circuit Descriptor Number:.
7/4/2004 Page 10 of 22 2 6102 3 6103 4 6104 5 6105 6 6106 7 6107 8 6108 9 6109 10 6110.
7/4/2004 Page 11 of 22 Create Digit Modification Assignment - in this example, we are using Digit Modification number 4 , and there are no digits to absorb or to insert Digit Modification Assignment D.
7/4/2004 Page 12 of 22 SX200 with ISDN • Attach VCon IGC server to PRI card with straight through cable o Configure hardware for Line Termination. Please refer to SX200 Technician ’s Handbook for more information.
7/4/2004 Page 13 of 22 Example of T1 PRI Programming on SX200 Refer to SX200 EL/ML Technicians Handbook , Programming a PRI, for System Configuration, Class of Service Options and System Options/System Timers. Form 13 Assign T1 E&M circuit descriptor to the ISDN trunk.
7/4/2004 Page 14 of 22.
7/4/2004 Page 15 of 22.
7/4/2004 Page 16 of 22 Define the incoming ISDN trunk as a Dial In trunk in form 15.
7/4/2004 Page 17 of 22 Assign the ISDN trunks to a trunk group in Form 16.
7/4/2004 Page 18 of 22 Select a T1 Link Descriptor for the ISDN trunks in form 42.
7/4/2004 Page 19 of 22.
7/4/2004 Page 20 of 22 Assign the ISDN link descriptor to slot 6 a nd/or slot 8 on the PRI card bay, Form 43 Form 44, Network Sync - To be determined by qualified Technician SX200 with T1/D4 • Attach VCon IGC server to SX200 with cross over cable. • Program trunks for T1/D4 .
7/4/2004 Page 21 of 22 T1 Crossover cable wiring Specifications [RJ45 Connector] Supplied with RemoteAbility system. Connector A Pin Connector B Pin 1 4 2 5 4 1 5 2.
7/4/2004 Page 22 of 22 Addition & Corrections The change I had to make was with the ANI/DNIS insertion in digit mod with T1/D4 trunks : The doc says above to insert **6135922122** The correct form.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Mitel 3300 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Mitel 3300 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Mitel 3300 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Mitel 3300 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Mitel 3300, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Mitel 3300.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Mitel 3300. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Mitel 3300 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.