P/N 775,147M Rev C, 11/04 Serefi na Series Direct V ent Gas Stoves These appliances may be installed in an aftermarket permanently located, manufac- tured (mobile) home, where not prohibited b y local codes .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 2 Input (BTU/HR) Manually-Modulated Gas Valves (millivolt models) Models Nat. Gas Propane CI1500DVF 17,500 to 28,000 20,500 to 27,000 CI2500DVF 25,500.
3 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. WARNING: F AILURE TO COMPL Y WITH THE INST ALLA TION AND OPERA TING INSTRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESUL T IN AN IMPROPERL Y INST ALLED AND OPERA TING APPLI- ANCE, VOIDING ITS WARRANTY .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 4 Figure 1 SPECIFICA TIONS H (with optional warming shelves) F E (with ashlip) DIMENSIONS CI1500DVF CI2500DVF A 24-1/2” (622 mm) 30-1/2” (775 mm) .
5 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. T op View / Corner Clearances * Dimensions with a single asterix are reference dimensions only . ** If the optional warming shelves are installed, a greater alcove width is required as follows: CI1500DVF - 44" (1118 mm) min.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 6 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LO WEST DISCHARGE OPENING OF VENT TERMINA T.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Figure 5 EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Vent T erminal = Area where T erminal is not Permitted = Air Supply Inlet X V D V 3 ft.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8 Remove the screws and support plate which secure the stove legs to the pallet. Lift stove off of the pallet and place it into position (where unit is to be installed). IMPORT ANT NOTE: If propane is used, be aware that if the tank size is too small (i.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Remove Cardboard Figure 9 Step 6: REMOVE CARDBOARD - Remove the cardboard packaging material from beneath the relief door and discard (see Figure 9). Wiring - Optional Forced Air Blower Kit: BK-CI (see Figure 11 for wiring diagram) - (An optional fi eld-provided outletbox/J-Box may also be used).
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 10 Figure 13 Figure 14 Horizontal Run (in feet) Vertical Run (in feet) Measure from the appliance fl ue collar to the top of the vent pipe Unacceptab.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Direct Vent Retrofi t Of Existing Chimney System An existing Class-A (wood-burning) Metal Chimney or Masonry Chimney can be converted to a direct vent system. Use one of the following chimney conversion kits listed below .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 12 DIRECT VENT SYSTEM COMPONENTS The following "Security Secure Vent TM " or "Simpson Dura-V ent" brand Direct-Vent components may be safely used with these appliances.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 13 Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 18 illustrates two methods for connecting the gas supply. The fl ex-line method is acceptable in the U.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 14 SIT Millivolt Gas Valve Controls H I L O W TPTH TP TH P I L O T P I L O T O N it O F F HI / LO Knob Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure Port Main Gas Control Knob Piezo Igniter IN OUT Figure 30 Step 13.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Figure 34 Adjustment Rod Up (1/8" Open Position) Air Shutter Burner T ube Adjusting Set Screw Adjustment Rod Down (full open position) Figure .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 16 Stove Cast Iron T op T rivet Ash Lip Step 16. INST ALL STOVE TOP , TRIVET AND ASH LIP A. Place the cast iron top into position on the stove top (See Figure 35). Place the trivet into the recess on the cast iron top (See Figure 35).
17 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. MODEL NO. CI1500DVF Series MANUFACTURED AT: Burlington, W A FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Printed in U.S.A. © 2003 Lennox Hearth Products P/N 775,147M REV . C 11/2004 1110 West T aft Avenue • Orange, CA 92865 Lennox reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox Hearth 775 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox Hearth 775 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox Hearth 775 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox Hearth 775 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox Hearth 775, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox Hearth 775.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox Hearth 775. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox Hearth 775 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.