Manuale d’uso / di manutenzione del prodotto GF 200 DV del fabbricante Jotul
Vai alla pagina of 28
WARNING: IF THE INFORMA TION IN THESE INSTR UC- TIONS ARE NO T FOLLOWED EXA CTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROP- ERTY D AMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR Y OUR SAFETY : DO NO T ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQ UIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 W elc ome to J ø tul... C ongratulations on the purchase of your new Jøtul GF 200 D V Lillehammer - a direct vented gas heater especially designed and approv ed f or installation in to a v ariety of configurations wher e close clear ance to combustibles is r equired.
3 T able of Contents Specifica tions .................................................. 3 General Inf ormation ...................................... 5 Saf ety Information ......................................... 6 Hearth Protection Requirements ....
4 Jøtul GF 200 D V Lillehammer Specifica tions Figur e 1. Dimensional V iews - GF 200 DV Lillehammer GF 200 DV Lillehammer Options • Fuel C onversion Kit - NG .............................. 155349 • Fuel C onversion Kit - LP .....................
5 DO NO T OPERA TE THE LILLEHAMMER GAS STO V E WITH THE GLASS FRONT REMO VED, CRACKED OR BR OKEN. REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. ONL Y REMOVE GLASS FOR ROUTINE SERVICE. ALWA Y S HANDLE GLASS CAREFULL Y .
6 Loca ting the Stov e In selecting the location, the aesthetic and func- tional use of the appliance are primary concerns. Howev er , proper v enting systems and access to the fuel supply are also important issues.
7 Clear ance to C ombustibles Minimum Stov e Clearance R ear 0” (0mm) Ceiling 17” (432mm) Corner 2” (51mm) Right Side 2” (51mm) Lef t Side *10” (255mm) * Necessary f or complete access to pull out required Ligh ting Instructions Plate.
8 Install the Exhaust Restric tor Pla te 1. R emove the T op Pla te to access the Glass Panel. 2. R elease the Glass P anel latches and lift the panel str aigh t up of f of the fireb ox . 2. Ca refully r emo ve the L og Set pieces from the fir ebox. 2.
9 35 Ft. (10.67 m) 30 Ft. (9.14 m) 25 Ft. (7.62 m) 20 Ft. (6.10 m) 15 Ft. (4.57 m) 5 Ft. (1.52 m) 1 Ft. (.30 m) 10 Ft. (3.05 m) 10 Ft. (3.05 m) 5 Ft. (1.52 m) VERTICAL RUN HORIZONT AL RUN F igure 7 . Install the Air Inlet R estrictor Plate. Rear W all of F irebox Air Deflector R emove this screw only Air In take R estric tor Plate T able 1.
10 Co-linear Hearthmount Installa tion The Jøtul GF 200 D V Lillehammer may be v ented through a masonry fireplace using Simpson Dura- V ent Chimney Liner Conv ersion Kit 923GK.
11 Masonr y or Pre fabricated Chimne y Co nv ersion The GF200 DV Lillehammer is approv ed for use with Simpson Dura-v ent Chimney Kit #934 in a masonry chimney or a pr efabrica ted solid fuel listed chimney . These installation requirements must be followed: 1.
12 Horiz ontal V enting (Horizontal T ermination) • The maximum horizon tal run made directly off the rear of the stove into a standard horiz ontal cap (#984 or #985) must be no more than a 9” section of Simpson Dur a-ven t (#907B). See F igure 12-1.
13 W all Shield Installation When horiz ontally v enting direc tly of f the rear of the stove, install the decorativ e W all Shield #129349, (included in the stove), to c over the top of the venting hole in the w all. See Figure 14. 1. R emov e the top four 1/4” he x head screw from the rear shroud of the stov e.
14 V ent T ermination Requirements Figure 15. V ent T erminal Clear ances - National Fuel Gas Code A = Clear ance abov e grade, veranda, porch , deck, or balcony : *12 inches (30 cm) minimum. B = Clear ance to window or door that may be opened: 9 inches (23 cm) minimum.
15 T ools Required: • 1/4” Nut driver • 7/16” and 1/2” open end wrench • T orx T -20 or slotted screwdriv er . Fuel Co nversion Kit C ontents: • 1 regulator tower labeled for Propane •.
16 Gas C on version Procedure See F igur e 29, page 25 for parts identification. 1. T urn off gas supply to the stove. 2 . Remov e the stov e T op Plate (3). 3. R emove the Fr ont Panel. Using a 10mm open- end wrench, loosen the two bolts holding the Fr ont Panel (1) to the side panels (2).
17 C onnec t the Gas Supply The gas supply line connection is made to the valve just inside the left r ear leg. The gas supply line should be 3/8" npt with a 1/2" diameter supply , or the appr opriate siz e to pro vide sufficien t gas pres- sure to the v alve r egardless of the input setting.
18 Leak T est: • Mix a 50-50 solution of water and dish soap. • Light appliance- see lighting instruc tions on page 21 of this manual or on the stove’ s rating plate.
19 Dera ting Procedure: T o derate this unit, install the appropria te orifice as shown in the High Altitude char t. 1. Remov e the two ¼” hex head screw that holds the burner tube/log support to the bottom of the stove. 2. R emove the burner tube/log support to e xpose the main burner orifice.
20 Install the Log Set The Lillehammer is equipped with a one piece log set and is packaged in bubble wrap inside the firebox. The log set must be removed fr om the pack aging and arr anged in the unit prior to start up of the gas stove. Do not handle the log set with your bar e hands.
21 1 (25mm) 3/8 (8mm) Min. 1/8 (3mm) Min. Ignitor Thermopile Thermocouple Checking the System 1. Purging the Gas Line: When ligh ting the appli- ance f or the first time it will take a few mo- ments to clear the gas line of air .
22 3. Burner Adjustment: The Lillehammer is equipped with a v ariable gas c ontrol v alve. that provides easy adjustment of the flame height appearance and hea t output . T o adjust the flame between the H I and LOW setting, rotate the HI / LO W knob, located in the cen ter of the valve f ace.
23 W ith proper care and main tenance, your Jøtul gas stov e will pro vide you with many y ears of service. If you experience any pr oblems with Jøtul GF 200 D V , c on tact y our authorized Jøtul dealer f or assistance. Fill out the Main tenance R ecord f orm on the next page and k eep it up to date.
24 Maintenance Rec ord Jøtul GF 200 Lillehammer Direct V ent Stov e Model: Serial Number: __________________________ Date of P ur chase: _______________________ Dealer: ______________________________.
25 3 21 Illustra ted Pa r ts List GF 200 DV Lillehammer 39 40 Figure 29. 12A 20 2 24 23 22 19 4 12 11 10 13 36 C A B 37 38 D 41 43 42 1 35 5 34 15 17 18 16 14 27 26 20 2 33 28 25 29 30 31 32.
26 10 Glass Frame 12931692 11 Glass Gasket (7/16” tadpole) 129124 12 Glass Clip 129135 Glass Frame Assembly 154337 12A Latch K eeper 129149 13 Glass 129113 14 Log Set 129122 * Embers 129123 15 Burne.
27 7. Push in gas con trol knob slightly and turn counter clockwise to “PI LO T” . 8. Push in contr ol knob all the way and hold in. Immediately ligh t the pilot by triggering the spark ignitor (push the red button repeatedly) until pilot lights. Continue to hold the c ontrol knob in for about one minute after the pilot ligh ts.
Jøtul ASA P .O . Box 1411 N-1602 Fr edrik stad, Norway Jøtul Nor th America 400 Riverside Stre et Portland, ME 04104 137743 1.03 Stoves and fir eplaces must be installed to c onf orm to local and na tional building regulations.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Jotul GF 200 DV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Jotul GF 200 DV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Jotul GF 200 DV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Jotul GF 200 DV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Jotul GF 200 DV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Jotul GF 200 DV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Jotul GF 200 DV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Jotul GF 200 DV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.