5RRP$LU&RQGLWLRQHU +($ 7&2175 2//(5,1& 6HUYLFH $QG3DUWV0DQXDO CAUTION webs • BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions .......................................................................................................................................... 3 Dimensions ......
Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. ■ Incorrect operation due to ignoring instruction will cause har m or damage.
4 Room Air Conditioner Saf ety Precautions Do not modify or extend the po wer cord. • There is risk or fire or electric shock. Do not install, remove, or re-install the unit b y y ourself(customer). • There is risk of fire, electric shock, e xplosion, or injury .
Dimensions Dimensions H W D Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner .
6 Room Air Conditioner Specfications Pr oduct Specifications POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (BTU/W.h) HEATING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) .
Se r vice Ma n ual 8 Installation INST ALLA TION How to Install the unit 1. To avoid vibration and noise, make sure the unit is installed securely and firmly. 2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning to shade the cabinet.
9 Room Air Conditioner Installation Window Requirements All supporting parts should be secured to firm wood, masonry, or metal. NOTICE • WINDO W REQUIREMENTS 1. This unit is designed for installation in standard double hung windows with actual opening widths from 29" to 41".
Se r vice Ma n ual 10 Installation Suggested tool Requirements SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL • PREP ARA TION OF CHASSIS 1. Remove the screws which fasten the cabinet at both sides and at the back. Keep these two screws which fasten the cabinet at both sides for later use.
11 Room Air Conditioner Installation Cabinet Installation 1. Open the window. Mark a line on the center of the win- dow stool between the side window stop moldings. Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut.
Se r vice Ma n ual 12 Installation 5. Pull each Frame curtain fully to each window sash track, and pull the bottom window sash down behind the Top retainer bar until it meets. 6. Attach each Frame curtain the window sash by using screws (Type C). (See Fig.
13 Room Air Conditioner Installation Operation Po we r T emp F an Speed Timer Mode Energy Sav er Au to Swing 1 4 2 6 7 3 5 REMOTE CONTROLLER 1. POWER BUTTON To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again.
Se r vice Ma n ual 14 Disassembly Disassembl y - Before the following disassembly, power switch is set to off and disconnected the power cord. Mechanical parts 1. Front grille 1. Open the inlet grille upward or downward. 2. Remove the screw which fastens the front grille.
15 Room Air Conditioner Disassembly Air handling par ts 4. Cover (at the top) 1. Remove the front grille. (Refer to section 1) 2. Remove the cabinet. (Refer to section 2) 3. Remove 11 screws which fasten the brace and covers. 4. Remove the covers and the brace.
Se r vice Ma n ual 16 Disassembly 6. Fan 1. Remove the cabinet. (Refer to section 2) 2. Remove the brace and shroud cover. (Refer to section 4) 3. Remove the side cover with 2 screws.(See Fig. 23) 4. Remove the 5 or 6 screws which fasten the condenser.
17 Room Air Conditioner Disassembly 10. CAP A CIT OR 1. Remove the control box. (Refer to section 3) 2. Remove the screw and knobs which fasten the display panel. 3. Disconnect the 2 leads from the rocker switch and remove the panel. 4. Remove a screw and unfold the control box.
Se r vice Ma n ual 18 Disassembly 13. SYNCHRONOUS MO T OR 1. Remove the control box. (Refer to section 3) 2. Unfold the control box. (Refer to section 10) 3. Remove the crankshaft. 4. Disconnect all the leads of the synchronous motor. 5. Remove the 2 screws which fasten the synchronous motor.
19 Room Air Conditioner Disassembly Refrigeration cyc le CA UTION: Discharge the refrigerant system using Freon TM Recovery System.If there is no valve to attac h the recovery system, install one (such as a W A TCO A-1) before venting the Freon TM . Lea ve the v alve in place after servicing the system.
Se r vice Ma n ual 20 - Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
21 Room Air Conditioner Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a leak-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
Se r vice Ma n ual 22 Schematic Diagram Schematic Dia gram Wiring Diagram ■ ELECTRIC HEATING MODEL.
23 Room Air Conditioner T roubleshooting Guide T roub leshooting Guide Piping System Figure 32 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
Se r vice Ma n ual 24 T roubleshooting Guide T roub leshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
25 Room Air Conditioner T roubleshooting Guide Fails to Start Check circuit breaker and fuse. Gas leakage of feeler bulb of thermostat Check of control switch. Fan only fails to start. Improper wiring. Defect of fan motor capacitor . Irregular motor resistance ( ).
Se r vice Ma n ual 26 T roubleshooting Guide COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if necessary. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification.
27 Room Air Conditioner T roubleshooting Guide COMPLAINT CAUSE REMEDY Check the position of knob If not at the coldest set- ting, advance the knob to this setting and restart unit. Check continuity of the thermostat. Replace ther- mostat if circuit is open.
6SHFLILFDWLRQVDQGSHUIRUPDQFHGDWDVXEMHFWWRFKDQJHZLWKRXWQ RWLFH +($ 7&21752//(5,1& :(// :25 7+$ 9(18(-$ &.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat Controller REG-183A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat Controller REG-183A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat Controller REG-183A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat Controller REG-183A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat Controller REG-183A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat Controller REG-183A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat Controller REG-183A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat Controller REG-183A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.