Manuale d’uso / di manutenzione del prodotto 63MAQ del fabbricante Hague Quality Water Intl
Vai alla pagina of 36
How to Use This Manual O g g Congratulations on your decision to place your confidence in a superior Hague water treatment appliance. Recognized nationwide for built-in quality, dependability, and ease of service, this appliance represents state-of-the-art in home water treatment.
How To Get The Maximum Efficiency From Your Appliance 1. Maintain salt level at least 1/3 full; use solar salt or pellets and purchase a clean grade of salt.
Checklist Before Installation 1. Water Pressure - Not less than 20 nor greater than 120 psi (1.4 - 8.4 bar) constant. (See Engineering Specifications, page 13.) 2. Water Temperature - Not less than 40° nor greater than 120°F (6°- 49° C). (See Engineering Specifications, page 13.
Do's And Don'ts SOME DO'S 1. Do install after the pressure tank on well water installations. 2. Do comply with all local building, plumbing and electrical codes. 3. Do install pressure-reducing valve if inlet pressure exceeds 90 psi. 4.
Wh en 8z How- To Use The Bypass Valve The bypass valve is intended to provide isolation of the WaterMax appliance in the event of a system malfunction, leak, or if the use of untreated water for watering plants, shrubs, or lawns is not available otherwise.
Installation Guide 8z Start-up Procedure Figure 1 From Meter From Well Cold Water r Hot Water Drain Line Water Heater C7WATERIIAX Pressure Tank r Maintain a min. 2 in. air gap Use this diagram as a location and installation guide for your 60 Series water conditioner.
Installation Guide & Start-up Procedure 1. Place the 60 Series in the desired location. Turn off the electricity and/or water supply to the water heater. Make sure the inlet, outlet and drain connec- tions meet the applicable local codes. Check the arrows on the bypass valve to be sure the water flows in the proper direction.
Setting And Using The Appliance Control Figure 2 SERVICE SETTINGS This section is recommended for qualified service personnel only. The appliance control must be set correctly for proper performance.
Setting And Using The Appliance Control (cont.) Description Of The Three WaterMax Operating Modes CAUTION: Be sure the controller is firmly "locked" onto the drive end cap assembly." The four tabs on top of the drive end cap will allow the clips on the bottom of the controller case to lock onto the end cap tabs.
Setting And Using The Appliance Control (cont.) 3.04 Push the NEXT button to step to the next Parameter. The display will show: Iron ppm 000 (Hist) This parameter is used to record the tested iron content of the water. 3.04a Push the the SELECT and CHANGE buttons until the desired iron number is reached.
Setting And Using The Appliance Control (cont.) 6.00 . Push the NEXT button to step to the next parameter. The display will show: Hard. Gr. 040 The 040 is the hardness number of the water tested. This number is to be the actual hardness reading and is not compensated for iron.
Setting And Using The Appliance Control (cont.) 14.00 Push the NEXT button to step to the next parameter. The display will show: Brine/Rinse 30.0 The "30.0" is the time, in minutes to the nearest tenth, for which the first brine and slow rinse cycles can be set.
F4,11gineering Specifications 60 SERIES 63MAQ 63BEQ* 63MXQ 63MDQ 62AMQ **62APQ*** 62AKQ 62AJQ**** Tannin (ppm) 0 0 0 0-2 0 0 0 0 Sulfur (ppm) - SulfurStat 0 0 0 0 0 0-5** 0 0 Iron (ppm) - ferrous - cl.
Mode I Setting Chart 60 SERIES 63MAQ 63BEQ * 63MXQ 63MDQ 62AMQ 62APQ ** *** 62AKQ 62AJQ **** Mode1 YES YES YES YES YES YES YES YES Regeneration Frequency As required As required As required 1 or 2 As .
Mode II Setting Chart 60 SERIES 63MAQ 63BEQ * 63MXQ 63MDQ ** 62AMQ 62APQ ** .*** 62AKQ ** 62AJQ **** Mode 2 YES YES YES NO YES NO NO YES Capacity As As As -- As — — As required required required r.
WaterMax Filters 61 AAN 61 AAE -BWO 61 AAR -BWO 61 AAS -BWO 61 AAF -BWO 10,000 N/A N/A N/A N/A 5 N/A N/A N/A N/A 20 N/A N/A N/A N/A 7 N/A N/A 5 ' N/A Manganese Greensand Activated Carbon Filter Ag Calcite/Corsex multi-Grade 1.25 1 1.25 1.25 1 6 6 6 6 6 10 10 10 10 12 7 5 5 7 7 .
Troubleshooting Problem Cause Solution Add salt. Remove the brine line and flush clean. Clean air check. Clean brine tank. Remove brine piston housing and clear debris from the flow control. Straighten, thaw or unclog the drain li ne. Remove injector cap and clean noz- zle and throat with a wooden tooth- pick.
Troubleshooting Problem Cause Solution Flow indicator blinks when water is not being used. (Fig. 2) No read-out in display. There is a leak in your household plumbing system. Electric cord is unplugged. No electric power at outlet. Defective transformer (fig.
Troubleshooting Problem Cause Solution Salty water Plugged injector. Low water pressure. Drain line or flow control is restricted. Brine line restricted or crimped. Excessive amount of water in brine cabinet. Insufficient rinse time. Intermittent pressure drop from feed source.
Parts - Figure 3-HOOK-UP/COVER ASSEMBLY ITEM NO. QTY. PART NO. DESCRIPTION 1 1 54501 Media Cabinet Cover Assembly 2 2 90837 Bypass Nut Gasket 3 2 90254 Copper Adapter 2 90256 PVC Adapter (optional) 4 .
Parts — Figure 4-BRINE TANK ASSEMBLY 1 PART# 54006 DESCRIPTION Brine Tank Cover QUANITY 2 90103 Brine Well Cap 3 54525 Safety Shutoff Assembly 1 4 54007 Support Panel (BT) 5 CO700A Cabinet Overflow .
Parts – Figure 5-Tank/Cabinet Assembly PART# DESCRIPTION QUANITY 1 93809 Screw 2 2 93870 Screw 4 3 90614 Drian End Cap Assembly 1 4 93808 0-Ring 2 5 93835 Sleeve 2 6 90238 Resin Tank Fill Plug 1 7 9.
Parts — Figure 6-Injector Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 1 93810 Injector Screen 2 1 93223 Injector Throat 3 1 93220 Injector Seal (Thick) 4 1 93221 Injector Nozzle 5 1 93232 Top Inje.
Parts – Injector Assembly 93223 Injector Throat: In conjunction with the Injector Nozzle, Part # 93221, it creates the vacuum that draws the brine solution from the brine cabinet. The center hole should be clear of debris,round and undamaged. The Throat should be pressed flush into the opening in the valve.
Parts Figure 7 -Bypass Assembly ITEM NO. QTY. PART NO. DESCRIPTION ITEM NO. QTY. PART NO. DESCRIPTION 1 12 90807 Screw 12 1 90263 Bypass Endcap - right 2 1 90262 Bypass Endcap - left 13 2 90828 0-Ring 3 2 93808 0-Ring 14 1 90226 Test Port Valve 4 6 90802 Screw 15 1 90812 Tubing 4.
Parts — Bypass Assembly 90246 Bypass Housing: Makes the connection between the plumbing and Main Valve Body. Also, contains the "Hard Water" Blending Valve and Bypass Piston. The recommended seal for the 1 '/" male inlet-outlet threads is the plastic Hook-up Nut (90251), 0-ring (90837), and Copper Adapter (90254).
Parts — Figure 8-Drive End Cap Assembly ITEM NO. QTY. PART NO. DESCRIPTION ITEM NO. QTY. PART NO. DESCRIPTION 1 2 90802 Screw 10 2 90818 Screw 2 1 90217 Drive Motor 11 1 93601-JG Brine Valve Housinq.
Parts – Drive End Cap Assembly 93583 Drive End Cap: Seals the two openings on the Main Valve Body. The larger diameter opening is sealed with an 0-ring used as an axial or "face" seal. The 0-ring sits in a groove in the End Cap. This groove must be free of defects such as pits or scratches and also free of debris.
Parts — Figure 9 - Brine Valve Housing Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 1 93620 Piston Assembly (includes 0-ring & Spring) 2 1 90821 0-Ring 3 1 93260 Housing 4 1 93878 Quad Ring 5 1 93254 Quad Ring Retainer 6 1 90843 .
Parts – Brine Valve Housing Assembly 93260 Housing: Should have a Quad-ring for the Piston seal. The Quad-ring (4) is held in place by the quad ring retainer (5).
Parts — Figure 10 - Fill Plug Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 1 90238 Fill Plug 2 2 90819 0-Ring (1) 90238 Fill Plug: The Fill Plug seals the media access ports in the Media Tank. Care should be taken that the 0-ring seal areas are kept clean and free of debris.
Parts - Figure 11 - Drain End Cap Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 1 93808 O-Rinq 2 1 90268 Drain End Cap 3 1 H2086-3.0 Drain Line Flow Control 4 1 90267 Retainer (1) 90268 Drain End Cap: Seals the left opening on the Main Valve Body. The opening is sealed with an 0-ring used as axial or "face" seal.
Parts - Figure 12 - Safety Shutoff ITEM NO. QTY. PART NO. DESCRIPTION 1 1 54226 Safety Shutoff 2 1 54227 Float 3 1 54225 Air Check 33.
Parts — Figure 13 - Brine Valve Elbow Installation 0 . a 1 /2" Retainer Sleeve The nut, gripper and retainer sleeve are a 3 piece assembly that can come apart if removed from the elbow body. Parts must be re-assembled exactly as shown to function properly.
25 Year Limited Warranty TO PLACE THIS EQUIPMENT UNDER WARRANTY, THE WARRANTY REGISTRATION CARD MUST BE COMPLET- ED AND RETURNED BY THE ORIGINAL OWNER TO HAGUE QUALITY WATER INTERNATIONAL WITHIN 30 DAYS OF INSTALLATION.
Brine Cabinet Data Based on the water level measured from the bottom of the WATERMAX brine cabinet WITH GRID PLATE, the following depths correlate to the amount of salt used per regeneration: DEPTH (inches) SALT (lbs.) 6 .74 7 1.5 8 2.2 9 3.0 10 3.7 11 4.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hague Quality Water Intl 63MAQ è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hague Quality Water Intl 63MAQ - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hague Quality Water Intl 63MAQ imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hague Quality Water Intl 63MAQ ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hague Quality Water Intl 63MAQ, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hague Quality Water Intl 63MAQ.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hague Quality Water Intl 63MAQ. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hague Quality Water Intl 63MAQ insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.