3A0156A Operation Electric Airless Spra yer s - For P ortable Airless Spraying of Ar chitectural Coatings and P aints - 3300 psi (227 bar , 22.7 MP a) Maximum W orking Pressure IMPORT ANT SAFETY INSTRUCTIONS Read all w ar nings and instr uctions in this manual.
Models: 2 3A0156A Models: 695 UL TRA MAX lIl Model QuikReel Hi-Bo y Lo-Bo y 258719 ✓✓ 258720 ✓ 258722 ✓ 258872 ✓ 258873 ✓ 258874 ✓ 258876 ✓ 258877 ✓✓ 826124 ✓✓ 826125 ✓ 82612.
Warnings 3A0156A 3 W arnings The f ollowing warnings are f or the setup , use, g rounding, maintenance and repair of this equipment. The e xclamation point symbol aler ts y ou to a general wa r ning and the hazard symbol ref ers to procedure-specific risks.
Warnings 4 3A0156A FIRE AND EXPLOSION HAZARD Flammable fumes , such as solvent and p aint fumes, in work area can ignite or e xplode. T o help pre vent fire and e xplosion: • Do not spra y flammabl e or combustible materials near an open flame or sources of ignition such as cig- arettes, motors , and electrical equipment.
Warnings 3A0156A 5 W ARNING EQUIPMENT MISU SE HAZARD Misuse can cause death or serious injur y . • Alwa ys wear appropriate glov es, eye protection, and a respir ator or mask when painting. • Do not operate or spra y near children. K eep children aw a y from equipment at all times.
Component Identification 6 3A0156A Component Identification 11. 12. 10. 13. 1. 2. 4. 5. 6. 7. 8. 9. 3. ti14839a 1 Premium Digital Display 2 ON/OFF Switch 3 W atchDog ™ Switch (not av ailable on Mar .
Grounding 3A0156A 7 Gr ounding The spra yer must be g rounded. Grounding reduces the risk of static and electric shoc k by pro viding an escape wire f or the electrical current due to static bu ild up or in the e v ent of a shor t circuit. The spra yer cord includes a gro unding wire with an appropriate gro unding contact.
15/20 Amp Switch (Not Available on All Units) 8 3A0156A 15/20 Amp Switch (Not A vailable on All Unit s) Select 15A or 20A setting based on your circuit rating. Pressure Relief Pr ocedure 1. T ur n power OFF . Wait 7 seconds f or power to dissipate. 2.
Setup 3A0156A 9 Setup 1. Standard Units Only : Connect Graco airless hose to spra yer . Tighten secure ly . 2. Standard Units Only : Connect other end of hose to gun and tighten securely . 3. Engage gun t rigger s af ety . 4. Remo ve t ip guard. 5. Check inlet strainer f or clogs and de bris.
Startup 10 3A0156A Star tup 1. T ur n pressure control to lowest pressure. 2. T ur n power ON . 3. Increase pressur e 1/2 tur n to star t motor and allo w fluid to circulat e through drain tu be for 15 seconds; turn pressure do wn. 4. T urn pr ime v alve forw ard to SPRA Y position.
Switch Tip Installation 3A0156A 11 Switch Tip Installation 1. Use spray tip (A) to inser t OneSe al ™ (B) into guard (C). 2. Inser t Switch Tip . 3. Scre w assemb ly onto gun. Tighten. Spra y 1. Spra y test patter n. Increa se pressure to eliminate heavy ed ges.
WatchDog ™ Protection System (Not Available on All Uni ts) 12 3A0156A W atchDog ™ Pr otection System (Not A vailab le on All Units) Pump stops automatically when m aterial pa il is empty . To A c t i v a t e : 1. P er f or m Startup . 2. Premium units with digi tal display: T ur n W atchDog swit ch ON and WD ON displa ys.
Hose Reel (Not Available on All Units) 3A0156A 13 Hose Reel (Not A vailab le on All Units) 1. Mak e sure hose is routed throug h hose guide. 2. Lift and tur n piv ot lock 90° to unlock hose reel. Pull on hose to remo ve it from hose reel. 3. Pull reel hand le up and tur n cloc kwise to reel in hose .
Digital Tracking System (Not Available on All Uni ts) 14 3A0156A Digital T rac king System (Not A vailab le on All Units) Operation Main Menu Shor t press to mo ve to next d isplay . Press and hold (5 seconds) to chang e units or reset data. 1. T ur n pressu re to lowest setting.
Digital Tracking System (Not Available on All Units) 3A0156A 15 Secondary Menu - Stored Data and W atchDog Pump Protection Modes 1. P er f or m Pressure Relief, steps 1 - 4 if they hav e not already been do ne. 2. T ur n pow er switch on while holding DTS button down.
Cleanup 16 3A0156A Cleanup 1. P er f or m Pressure Relief Procedure (page 8), steps 1 - 4. Remo ve siphon tube set from paint and place in flushing flui d. Remov e tip guard from gun. NO TE : U se wa ter for wat er- bas e paint, mineral spir its f or oil-base paint, or othe r solvents reco mmended by manuf acturer .
Cleanup 3A0156A 17 9. Remov e filters from gun an d spra yer , if installed. Clean and inspect. Install filters. 10. If flushing with water , flush again with mineral spirits, or Pump Ar mor , to leav e a protective coating to pre- vent freezing or corrosion.
Technica l Data 18 3A0156A Te c h n i c a l D a t a Basic Sprayer Wetted Parts......... ..................... zinc- and nick el-plated carbon steel, nylon, stainl ess steel, PTFE, Acetel, leather , UHMWPE, aluminum tungsten carbide, PEEK, brass Noise Level Sound powe r .
Notes 3A0156A 19 Notes.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 3A0156 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco Inc. ti15036a è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco Inc. ti15036a - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco Inc. ti15036a imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco Inc. ti15036a ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco Inc. ti15036a, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco Inc. ti15036a.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco Inc. ti15036a. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco Inc. ti15036a insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.