312473B ENG Instr uctions - P ar ts Fine x Air spra y P a ck ag e S p r a yer P ac kage solutions for pumping and spraying finishing mate rials. For pr ofessional use only . Models: 289353 with Finex Air spra y Gun 100 psi (7 bar , 0.7 MP a) Maximum W orking Pressure 289354 with Finex HVLP Gun 100 psi (7 bar , 0.
Related Manua ls 2 312473B Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings 312473B 3 Wa r n i n g s The f ollowing w arnings are for the set up , use, gr ounding, maintenance , and repair of this equipment. Th e exclama - tion point symbol ale r ts you to a gener al warning and the hazard symbol r efer s to procedure-spe cific risk.
Warnings 4 312473B T O XIC FLUID OR FUMES HAZARD T o xic fluids or fumes ca n cause serious injur y or death if splashed in the e yes or on skin , inhaled, or s wallowed.
Installation 312473B 5 Installation Gr ounding The equipment m ust be grounded. Grounding reduces the risk of static and electric shock b y providing an escape wire f or the electrical current du e to static b uild up or in the e v ent of a short circuit.
Controls and Components 6 312473B Contr ols and Components Spra yer Contr ols • Pump air pressure regulator (C): a loc king regula- tor to adjust a ir pressure to th e motor and fl uid outlet pressure of pump . View the air pressure gauge to read air pr essure.
Typical Installation 312473B 7 T y pical Installation Key: AP u m p B Bleed-type Master Air Line Shutoff V alv e C Pump Air Pressure Regul ator D Gun Air Pressure Regul ator E Gun Fluid Pressure Regul.
Pressure Relief 8 312473B Pressure Relief F ollow pressure relief procedu re when y ou stop spra y- ing and bef ore cleaning, chec king, or servicing the equipment. 1. Shut off the b leed-type air v alv e. 2. Hold the gun firmly against a grounded metal pail and tr igger the gun.
Grounding 312473B 9 Gr ounding 1. Connect the g round wire clamp to a true ear th ground. 2. Ground the object being spra y ed, fluid supply con- tainer , and all other equi pment in the spray area. 3. Ground all solvent pails. Use only metal pails. Do not place on a non-conduct ive surf ace such as paper or card board.
Prime 10 312473B Prime 1. Shut off both air regulators and th e bleed-t ype air va lve . 2. Shut off the fl uid regulator . 3. Install the air cap . 4. Place the suc tion tube in the fluid. 5. Open the b leed-type air v alv e. 6. Open the pump air regulator until the pump starts.
Spraying 312473B 11 Spra ying 1. Adjust fluid flo w using the pump air reg ulator or the fluid pressure regulator . 2. Adjust fluid pressur e so stream from gun tr av els 6–8 in. straight bef ore f alling off . 3. Adjust the gun air regula tor to achie ve proper spra y gun atomizat ion.
Maintenance 12 312473B Maintenance 1. Flush. See Flush , page 9. 2. Clean the air cap and fluid nozzle. 3. Clean the suction tube and inlet str ainer , u sing a compatible solv ent. 4. Clean t he outside of the spray er , using a soft cl oth and compatib le solv ent.
Troubleshooting 312473B 13 T r oub leshooting Relie v e pressure bef ore serv icing. See Ty p i c a l Installa tion , page 8. Prob lem Cause Solution Pump will not r un, or stops . Air line valv e shut off . Open valv e . Clogged fl uid line or spr ay g un.
Parts 14 312473B Pa r t s 289353 with Fine x Airspra y Gun 289354 with Fine x HVLP Gun TI10872A 1 15 17 13 11 6 3 4 5 7 8 9 18 24 16 21 12 23 2 10 19 22a, 22b 25 Ref.
Dimensions 312473B 15 Dimensions Te c h n i c a l D a t a Sound le v els: Ref er to related pump an d gun manuals . See page 2. 19.26 in. (48.92 cm.) 19.19 in. (48.74 cm.) 12.02 in. (30.53 cm.) TI10874A TI10873A Maximum fluid wor king pres sure . . . .
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. This manual contains English. MM 312473 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco Inc. 312473B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco Inc. 312473B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco Inc. 312473B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco Inc. 312473B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco Inc. 312473B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco Inc. 312473B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco Inc. 312473B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco Inc. 312473B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.