308–332 Rev . D Supersedes Rev . C and PCN D First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. ST AINLESS STEEL, 15:1 RA TIO Monark Sprayers 2700 psi (18.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . .
INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed into the eyes or onto the skin can also cause serious injury .
4 308-332 FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 308-332 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4.
6 308-332 Installation Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip - ment. Reference numbers and letters in parentheses refer to the figures and the parts lists on pages 10–13.
7 308-332 Installation Fig. 3 KEY A Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Master Air V alve (for accessories) E Air Line Filter F Pump Air Regulator G Gun Air Re.
Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serious injury .
Fig. 4 W all Mount Pumps (Model 236–065) 16 21 34 6 10a 10b 29 Pail Mount Pumps (Model 236–069) 10a 29 10b 6 16 40 1 42 Operation Slowly open the pump air regulator (10b) until the pump starts. Run the pump slowly until fluid comes from the drain valve (6).
10 308-332 Parts Part No. 236–065 W all Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 W all Mount Pump without Fluid Regulator Includes items 1–28, 43–50 02802A 1 See Detail at left.
11 308-332 Parts Part No. 236–065 W all Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 W all Mount Pump without Fluid Regulator Includes items 1–28, 43–50 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty .
12 308-332 Parts Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 2 8 9 Apply thread sealant to male threads, except at swivel connections.
13 308-332 Parts Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty .
14 308-332 Notes.
15 308-332 T echnical Data Category Data Maximum working pressure 2700 psi (18.5 MPa, 185 bar) Maximum incoming air pressure 180 psi (1.25 MPa, 125 bar) Ratio 15”1 W etted parts: Pump See manual 308.
16 308-332 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco Inc. 236-900 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco Inc. 236-900 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco Inc. 236-900 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco Inc. 236-900 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco Inc. 236-900, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco Inc. 236-900.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco Inc. 236-900. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco Inc. 236-900 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.