Instructions–Parts List 306706W ST A TIONAR Y AIRLESS P AINT SPRA YER 30:1 President R Hydra–Spray R Used for airless spray application of paints and other coatings from a 50–gallon drum. 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure 100 psi (0.
2 306706 T able of Contents W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Grounding 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positioning the Unit 6 . . . . . . . . . .
306706 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment.
4 306706 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
306706 5 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 6.
6 306706 Installation NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. D Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.
306706 7 Installation The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories D Ground the unit as described in Grounding on page 6.
8 306706 Operation/Maintenance Pressure Relief Procedure SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury .
306706 9 Operation/Maintenance 3. Push in on the air valve knob to lower the elevator , so the cover (A) rests on the top lip of the drum. The support clamp (K) recesses must be tight against the elevator riser tube. The pump intake valve feet (B) must contact and support the perfo- rated plate (9) as shown in Fig.
10 306706 Parts Drawing Model 231063, Series C, 30:1 President R Hydra-Spray R A A A 06218A 31 19 06218 1 2 3 4 5 6a 6b 6c 6d 6e 7 8 9 10 11 12 43, 44 15 46 20 45 21 23 24 25 26 28 29 30 48 31 32 34 3.
306706 1 1 Parts List Model 231063, Series C, 30:1 President R Hydra-Spray R Ref. No. Part No. Description Qty . 1 202295 V AL VE, push-pull See 306287 for parts. 1 2 203743 V AL VE, restrictor See 306287 for parts. 1 3 204385 ELEV A TOR See 306287 for parts.
12 306706 Notes.
306706 13 T echnical Data Ratio 30:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum fluid working pressure 3000 psi (21 MPa, 207 bar) . . . . . . . . . . . . . . . .
14 306706 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco Inc. 231063 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco Inc. 231063 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco Inc. 231063 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco Inc. 231063 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco Inc. 231063, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco Inc. 231063.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco Inc. 231063. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco Inc. 231063 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.