307741 Rev . R First choice when quality counts. t 03695A Model 220106 Shown INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 255 mm (10 in.) DIAMETER Quiet King R Air Motor 0.
2 307741 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 7 . . . . . . . . . . . . . .
3 307741 W ARNING INJECTION HAZARD Spray from the gun/valve, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 307741 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 307741 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor .
6 307741 Installation Noise Reduction Instruction Manual 307375 is supplied with this motor . It provides information on noise reduction. The following are additional recommendations for Maximum Noise Reduction: D The air line should be connected to the air motor inlet with an electrically conductive flexible hose.
7 307741 T roubleshooting Pressure Relief Procedure W ARNING INJECTION HAZARD T o reduce the risk of serious injury , in- cluding fluid injection, splashing in the eyes or on the skin, or moving parts.
8 307741 T roubleshooting Air Leaks Air leaks are caused by worn or damaged gaskets or seals. T o locate the leaks, first shut off the air supply to the pump and open the bleed-type master air valve to relieve air pressure. Disconnect the main air supply line from the air inlet.
9 307741 T roubleshooting 03705A Fig. 2 D (30*) E (3) G (38*) F (33*) C (44*) *45, *46 B (*35) *65 H (15) K (26) 29 Model 220106 Shown 1 2 Pack cavity with light waterproof grease.
10 307741 Service W ARNING T o avoid serious injury and equipment damage, do not lift the equipment by the air motor lift ring if the total weight of the equipment exceeds 550 lb (250 kg). The lift ring cannot support that weight. T ools Required D Padded pliers, Part No.
11 307741 Service NOTE: Refer to Fig. 4 for steps 6 to 1 1. 6. Remove the screws (31) and lockwashers (13) from the manifold (20). 7. T o prevent the spring-loaded director valves (3) from popping out, carefully lift the manifold (20) up about 51 mm (2 in.
12 307741 Service NOTE: Refer to Fig. 5 for steps 12 to 18. 12. Remove the rubber pad (8) from the cylinder (36). Remove the trip rod bearing (37), using a 1 in. deep-well socket wrench. Remove the gasket (66), v-block packing (65), and backup washer (64) from the bearing.
13 307741 Service 03701 07283A Fig. 5 34 33 40 39 46 45 44 70 35 47 8 37 66 64 65 36 13 31 34 47 40 07421A 41.
14 307741 Service Reassembly 1. Clean all parts thoroughly and inspect for wear or damage. Replace parts as necessary . NOTE: Refer to Fig. 6 for steps 2 to 5. 2. T urn the base (47) upside down. If the bearing (70) was removed, press-fit the new bearing so its top edge is flush with the shoulder (S) of the packing cavity .
15 307741 Service NOTE: Refer to Fig. 7 for steps 6 to 10. 6. Grease the trip rod (40) with light, water-proof grease and slide it into the piston (34) shaft. Clean the threads of the piston and the connecting rod stud (39). Apply Loctite R 242 or the equivalent to both.
16 307741 Service NOTE: Refer to Fig. 8 for steps 1 1 to 16. 1 1. Place the gasket (38*) on top of the cylinder (36). 12. Thread the hub (10) onto the trip rod (40). Lift the rod and grasp it with the padded locking pliers. Screw the hub down as far as possible by hand.
17 307741 Service NOTE: Refer to Fig. 9 for steps 17 to 22. 17. Lubricate the housing (18), spring (17), and guide (16) with light, water-proof grease. Assemble the housing and spring into the guide. Lubricate the pin (19) and slide it into the housing.
18 307741 Parts Model 220106, Series A Standard Quiet Air Motor 03696A 25 67 32 68 69 63 62 24 26 23 21 27 28 53 29 *30 8 20 31 13 19 18 17 16 15 14 12 1 1 10 7 6 5 4 3 2 1 *38 8 37 66 *65 *64 43 44* .
19 307741 Parts Model 220106, Series A Standard Quiet Air Motor Ref No. Part No. Description Qty Ref No. Part No. Description Qty 1 168184 SEAL, plate 2 2 176536 PLA TE, valve 2 3 n 176518 V AL VE, di.
20 307741 Parts Model 235525, Series B Quiet Air Motor 03698A 25 68 63 62 24 26 23 27 28 53 29 *30 8 20 31 13 19 18 17 16 15 14 12 1 1 10 7 6 5 4 3 2 1 *38 8 37 66 *65 *64 43 44* 31 13 41 47 45* 46* 3.
21 307741 Parts Model 235525, Series B Quiet Air Motor Ref No. Part No. Description Qty Ref No. Part No. Description Qty 1 168184 SEAL, plate 2 2 176536 PLA TE, valve 2 3 n 176518 V AL VE, director 2 .
07420A 25 68 69 63 62 24 26 23 27 53 29 *30 8 20 31 13 19 18 17 16 15 14 12 1 1 10 7 6 5 4 3 2 1 *38 8 37 66 *65 *64 43 44* 31 13 41 47 45* 46* 39 40 34 33* 35* 36 76 77 78 81 83 88 83 79 84 85 86 82 .
23 307741 Parts Model 237000, Series A Reduced Icing Quiet Air Motor Ref No. Part No. Description Qty Ref No. Part No. Description Qty 1 168184 SEAL, plate 2 2 176536 PLA TE, valve 2 3 n 176518 V AL V.
24 307741 Dimensions 03702 03695 3/4 npsm(f) Swivel Air Inlet 3/4 npt(f) Swivel Air Inlet 03697 Maximum Diameter: 305 mm (12 ” ) 1 – 1/4 npt Exhaust Port 16 Exhaust Holes. Plug when exhausting to outside or through muf fler 94 mm (3.712 ” ) 88 mm (3.
25 307741 T echnical Data Category Data Maximum Incoming Air Pressure 0.6 MPa, 6.2 bar (90 psi) Effective Piston Area 506 cm @ (78.5 sq. in.) Piston Diameter 255 mm (10 in.
26 307741 Notes.
27 307741 Notes.
28 307741 The Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco Inc. 220106 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco Inc. 220106 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco Inc. 220106 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco Inc. 220106 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco Inc. 220106, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco Inc. 220106.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco Inc. 220106. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco Inc. 220106 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.