PELLET STOVE EF- ΙΙ i OWNER’S TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD VICTORIA, BRITISH COLUMBIA V8M - 2A3.
ENVIROFIRE INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION Important Safe ty Data ...................................................................... 3 Pellet Q uality .............................................................................
IMPORTANT SAFETY DATA Please read this entire manual befo re installation and use of this pellet fuel bu rning room heater. Failure to follo w these instructions could result in prop erty damage, bodily injury or even death.
PELLET QUALITY IS IMPORTANT, PLEASE READ THE FOLLOWING PAGE Your pellet stove has been designed to burn wood pellets only. Since there are many manufacturers of wood pellets it is important to select pellets that are free of dirt or any impurities. The Pellet Fuel Industries (P.
WARNINGS AND RECOMMENDATIONS A. Do not abuse the glass by striking or slamming the door shut. B. Do not attempt to operate the stove with broken glass. C. Do not attempt to open the door and clean the glass while the unit is in operation. If you must clean the glass, use a soft cotton cloth and mild window cleaner.
HOW TO START YOUR PELLET APPLIANCE 1. Fill hopper with pellets. 2. Switch the power on by pushing the rocker switch to the manual position. FAN CONTROLLER 3. Turn Dial A Fire knob to the 12 o’clock position. (The lower grade pellets may need a higher setting on the feed rate.
SLIDER/DAMPER INSTALLATION /OPERATIONS INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION: 1. Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. This is the smaller of the two rods.
AREAS FOR ROUTINE INSPECTION The following should be inspected perio dically to ensure that the a ppliance is operating at it s optimum and giving you excellent heat value: 2-3 DAYS/WEEKLY SEASONALLY .
DOOR GLASS (It is recommended that your dealer replace the glass if broken.) The door glass is made of 5 mm thick, high tempe rature PYROCERAMIC The center panel is 229 mm x 33 0 mm. To replace the glass, unscrew and remove the four glas s retain ers.
ELECTRICAL COMPONENT FUNCTIONS The following is a list of electrical compo nents and th eir functions on the ENVIROFIRE EF-IIi pellet stove. 1. CONVECTION FAN CONTROL LER This controller is respon sible for varying the speed of the co nvection blower.
10. 160 ° F (71 ° C) TEMPERATURE SENSOR When this sensor (located on the left sid e firewall) reaches 160 ° F (71 ° C), the convection blower will go to hi gh, cooling the unit.
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 1. Check clearance s to combustibles. 2. Do not obtain com bustion air from an attic, gara ge or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom.
REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet , open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the sid e panels. See PAGE 18 how to install the pedestal.
MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI The Fireplace insert model includes a surround faceplate and a pedestal. When installing this unit, ensure that the pedestal is removed from the inside of the hopper and installed on the bottom of the unit.
ASSEMBLING THE FACE PLATE FOR THE FPI AND BIH MODELS 1. Assemble the brass frame using the corner hardware a nd screws supplied in the face place packaging. Install corner hardware into the side brass, then push into the top frame. Do not over- tighten or the side bass cannot be removed during servicing.
RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3” (75 mm) pedestal and surrounding faceplates.
CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTI BLES (FREESTANDING) - Side wall to unit A- 6 INCHES (150 mm) - Back wall to unit B- 1 INCH (25 mm) - Corner to unit C- 1 INCH (25 mm) - Mantle (Hearth .
MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION Model FS comes with a pede stal that has to be attache d prior to installation: - Remove the pede stal from the box - Remove the ENVIROFI RE unit from the box - Place the unit on its back, making sure not to damage the wiring.
HORIZONTAL EXHAUST THROUGH THE WALL 1. NOTE: Use only listed type “PL” or “L” pellet venting products . Failure to u se listed components may cause damage or personal injury or death.
THROUGH WALL INSTALLATION 1” 20.
INSIDE VERTICAL INSTALLATION, MODEL FS 1. Choose a stove location that is ideal. See the section Deciding Where to Locate You r Pellet Appliance. 2. Place on a noncombustible hearth pad where necessary.
OUTSIDE VERTICAL PIPE INSTALLATION To accomplish the above titled installation, foll ow steps 1 through 8 in the previous section (HORIZONTAL EXHAUST THROUGH THE WALL) and then finish it by performing the following: 9 Install a tee with clean out on the outside of the house.
MOBILE HOME INSTALLATION - Secure the heater to the floor using the two bolt holes in the pedestal. - CAUTION: THE STUCTURAL INT EGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. - Ensure the unit is electrically grounded to the chassis of your home (permanently).
TROUBLESHOOTING DO NOT: - Switch the stove ON and OFF rapidly. This may caus e current spikes, which could sh orten the life of the electrical components. - Service the stove with wet hands. The st ove is an elec trical appliance, which may pose a shock haza rd if handled improperly.
3) The stove will not function in the “AUTO” mode when hot - If the unit fails to operate, by-pass the auto side of th e switch by in serting a jumper wire b etween the dual black wires and the dual b rown wires located on the b a ck of the switch.
POTENTIOMETER READINGS: Full clockwise (switched off) = open circuit, overload or infinite resistan ce LOW FIRE 800K OHMS to 900K OHMS HIGH FIRE 68K OHMS to 82K OHMS - If the range does not vary or the switch doe s not close then repl ace the potentiometer.
WIRING DIAGRAM 27 27.
PARTS LIST EF-001 AUGER MOTOR EF-087 GOLD DOOR COMPLETE EF-002 CONVECTION BLOWER EF-088A LOG SET (20-036) EF-004 CONVECTION BLOWER IMPELLER EF-089 FS PEDESTAL BRASS TRIM EF-007 COMBUSTION BLOWER COMPL.
EF 2 FULL PEDESTAL ASH PAN EF-159 ASH PAN LATCH EF-105 DOOR HANDLE EF-030 EF 2 GLASS EF-061 PAINTED DOOR COMPLETE EF-085 GOLD DOOR COMPLETE EF-087 EF 2 ASH SILL EF-103 EF 2 FRONT GRILL EF-106 FIREBOX .
30 AUGER BRASS BUSHING SET OF TWO EF-065 AUGER TIMER CONTRO L EF-036 GREEN LIGHT EF-041 FAN CONTRO LLER EF-045 CONTRO L PANEL W/DECAL EF-053 CONVECTION BLOWER EF-002 HIGH LIMIT SENSOR 200 ° F (93 ° .
WARRANTY Sherwood Industries Ltd. gives a five year limited wa rranty on all steel manufactured parts. A one-year warranty is provided on all electrical components.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enviro EF-II I è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enviro EF-II I - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enviro EF-II I imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enviro EF-II I ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enviro EF-II I, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enviro EF-II I.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enviro EF-II I. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enviro EF-II I insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.