50-1578 TECHNICAL MANU AL PELLET ST OVE WINDSOR SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER.
2 T able of Contents Safety W arnings & R ecommendations.........................................................................3 Installation........................................................................................................
3 Safety W arnings & Recommend a tions * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
4 Safety W arnings & Recommend a tions CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will v ary due to the ash content of the f uel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi- annually or every two tons of pellets.
5 Safety W arnings & Recommend a tions FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “ Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly .
Inst alla tion R ATING L ABEL L OCATION : The rating label is located on the back of the hopper . D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles (see I NSTALLATION - C LEAR ANCES TO C OMBUSTIBLES and I NSTALLATION - A LCOVE C LEARANCES ).
7 Figure 2: Windsor Dimensions. 27 1 / 8 " (689mm) 25 3 / 4 " (653mm) 25 7 / 8 " (659mm) 15 3 / 8 " (390mm) 14 1 / 4 " (360mm) 24 1 / 8 " (614mm) Inst alla tion D IMENSIONS & S PECIFICATIONS : T able 1: Windsor Specifications.
This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figur e 4. Minimum Alcove width 1220mm (48 inches) Minimum Alcove height 1220mm (48 inches) Maximum Alcove depth 915mm (36 inches) Install vent at clearances specified by the vent manufacturer.
9 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elev ation.
10 10 1 / 2 ” (265 mm) 8 1 / 2 ” (216 mm) 12 7 / 8 ” (326 mm) 8 3 / 8 ” (214 mm) 4 3 / 8 ” (1 12 mm) EXHAUST Base of unit to center of flue 270 mm (10 ”) Side of unit to center of flue 308 mm (12 ”) Center of unit to center of flue 19 mm (”) FRESH AIR INTAKE.
11 Figure 8: Corner Installation. 100mm (4") 100mm (4") Fresh Air Intake W all thimble manufactured by pellet vent manufacturer . Inst alla tion C ORNER T HROUGH W ALL I NSTALLATION : H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the vent manufacturer.
Exhaust 80mm (3") or 100mm (4") Vent Pipe Wall Thimble 45 o Elbow with Screen or Termination Cap High Temperature RTV Silicone Required Fresh Air Intake Wall framing Wall thimble Termination.
13 Inst alla tion V ERTICAL R ISE WITH H ORIZONTAL T ERMINATION I NSTALLATION (R ECOMMENDED ): A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
Storm Collar Roof Flashing Roof Rafters Fire Stop with Support Collar Ceiling Joist Vertical Vent Pipe Clean Out Tee with Pipe Adapter ENVIRO Windsor Note: All vent sections must maintain 3" (75mm) clearances to combustibles.
15 Inst alla tion O UTSIDE V ERTICAL I NSTALLATIONS : T o accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “ I NSIDE V ERTICAL I NSTALLATIONS - F REESTANDING ” section and then finish it by performing the f ollowing (refer to Figure 14).
Storm Collar Existing Masonary Flue Flexible Vent Connector (use this 1.5m (5ft) section of pipe to vent past the fireplace damper or smoke shelf) Seal Plate Fireplace Damper Location Vertical Vent Pi.
17 Install blower motor onto exhaust blower housings. Completed assembly. Exhaust Motor Cover Plate Access Panel Inst alla tion I NSTALLATION WITH E XTERIOR M OUNTED E XHAUST B LOWER : The WINDSOR can be equipped with an externally mounted exhaust blower (PAR T #50-492).
TO SUPPLY POWER TO THE EXHAUST BLOWER: Install an amour coated electrical cable from the exhaust blower housing, thr ough the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar . Hook up to wires fr om the wiring harness for the exhaust blower .
19 Storm Collar Roof Flashing Roof Rafters Roof Sheathing Ceiling Joist Vertical Vent Pipe Outside Vent Termination Exterior Wall Sheathing Rain cap - ensure cap is at least 900mm (3 ft) above the roo.
S LIDER /D AMPER S ETTING : THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE THE AIRFLOW THROUGH THE PELLET STOVE. A Qualified Service Technician or Installer must set the Slider Damper .
21 • A tall, lazy flame with dark orange tips r equires more air – Open slider (pull out) slightly . • A short, brisk flame, like a blowtorch, has too much air – Close slider (push in) slightly .
T roubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication.
23 T roubleshooting ü Check vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the vacuum hose from vacuum switch. Check exhaust vacuum readings by placing the open end of the vacuum hose on a Magnahelic Gauge (readings must be above 0.
T roubleshooting ü If the auger gear box does not turn but the motor ’ s armature does try to spin then the auger is jammed. – T ry to break apart jam by poking at the jam through the drop tube.
25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White White Orange Orange Orange Orange Yellow Yellow Grey Grey Purple Purple Blue Black Bla.
Reference Number Description Part Number 1 120 °F (49 °C) Ceramic F an T emperature Sensor EC -001 2 Auger Motor - 220V EF-001-220V 3 High Limit T emp Sensor 200 °F (93 °C) Manual Reset EF-016 Sil.
27 Reference Number Description Part Number Auger Motor Mount 50-687 Auger Plate with bushing 50-688 Auger Mounting Hardwar e 50-689 22 IEC Power Cor d Inlet Socket 50-713 Hinge Pin - Silver 50-750 Ov.
P ar ts List - Cast Reference Number Description Part Number 41 Cast Ash Shelf - P ainted 50-192 42 Cast Front Complete (Doors & Ash Shelf ) - Painted 50-202 43 Cast Side Left - P ainted 50-203 44.
WINDSOR - Components May 2007 P ar ts Diagr am - Components 29.
WINDSOR - Steel & Cast May 2007 .
31 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Enviro 50-1578 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Enviro 50-1578 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Enviro 50-1578 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Enviro 50-1578 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Enviro 50-1578, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Enviro 50-1578.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Enviro 50-1578. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Enviro 50-1578 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.