T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 www .daniel.com Daniel ® Liquid T urbine Flow Meter T echnical Guide Liquid T urbine Flow Met ers.
.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 T ABLE OF CONTENTS T urbine Meter Parameters ............................................................................................................................. 1 The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 +0.15% –0.15% +0.02% –0.02% TURBINE METER P ARAMETERS These ve terms are the most widely discussed parameters of turbine meter applications. Linearity is the measure of variation in signal output across the nominal ow range of the meter .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 2 THE DANIEL ® SERIES 1200 AND 1500 LIQUID TURBINE FLOW METER SYSTEMS The Daniel Series 1200 and 1500 Liquid T urbine Flow Meter Systems combine turbine meters and electronic instrumentation to measure volumetric total ow and/or ow rate.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 3 Daniel ® V alves In Load Rack Duty TURBINE METER THEOR Y The basic theory behind Daniel’s electronic liquid turbine meters is relatively simple.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 4 P A TENTED* FLOA TING ROT OR Flowing uid enters the turbine through the forward suspension. When it encounters the sharp angle of the cone, the stream is deected outward, increasing in velocity and causing a slight static pressure drop.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 5 Surge And Pressure Relief V alves MAGNETIC PICKOFF OF ROTOR VELOCITY The angular velocity of the turbine rotor is taken through the turbine meter wall by means of a magnetic pickoff.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 6 TURBINE METER ROTOR AND BEARING DESIGN The primary differences in turbine meter technology are in the design of the rotor and bearings. The rotor is an assembly of up to twelve (in some designs this number is greater) blades locked into a hub, which rotates on a bearing or bearings.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 7 RIMMED ROTORS FOR HIGHER RESOLUTION In the larger diameter Daniel Series 1500 Liquid T urbine Flow Meter (normally above 6” in line size), the resolution provided by a blade-type motor may be improved by the use of a rimmed (or shrouded) rotor .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 8 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER Daniel Series 1200 Liquid T urbine Flow Meters are designed specically for load rack service where a vital characteristic is repeatability .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 9 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEA TURES The following data is applicable for Daniel Series 1200 Liquid T urbine Flow Meter calibrated on mineral spirits.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 10 DANIEL ® SERIES 1200 LIQUID TURBINE FLOW METER MA TERIALS OF CONSTRUCTION Standard Optional Body/Flanges 1” and 1.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 1 1 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER The Daniel Series 1500 Liquid T urbine Flow Meter is designed for applications requiring rugged dependability with high accuracy and throughput.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 12 The deployment of this high resolution rotor in each of the sizes available gives a nominal K-factor twice that of the standard meter and allows for proving with a smaller size prover .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 13 Item Standard Optional Optional Meter body and anges 304 Standard 1” and 1.5” NA 316 SS CS Standard 2” and up 304 SS 316 SS.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 14 RANGEABILITY OF LIQUID TURBINE FLOW METERS The ow ranges indicated in the previous tables show a nominal ow range -- with a tu.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 15 DANIEL ® SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRA VITY ADJUSTMENTS S.G. = 1 ( .7 to 1 ) Meter Size Minimum Linear Maximum Linear BBL/Hr M 3 /Hr USGPM BBL/Hr M 3 /Hr USGPM 1 10 1.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 16 METER PERFORMANCE IN HIGH VISCOSITY LIQUIDS Increases in viscosity of the measured liquid will reduce the rangeability of the ow meter . Generally , the minimum ow rate of the meter will have to be increased to maintain the linearity rating of the meter .
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 17 INST ALLA TION AND OPERA TING RECOMMENDA TIONS For a turbine meter to perform without increased uncertainty and in a repeatable and accurate manner , the owing stream must be free of rotational components.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 18 Figure 14 - Effects of Back Pressure In some circumstances, the use of a Flow Conditioning Plate (FCP) is possible.
T echnical Guide DAN-LIQ-T urbine Meter-TG-0807 August 2007 Page 19 DUAL CHANNEL PREAMP TERMINAL IDENTIFICA TION CUSTOMER CONNECTIONS BLACK OR RED PICKOFF PICKOFF WHITE WHITE CHANNEL B CHANNEL A BLACK OR RED T U P T U O B .
.
Emerson Process Management Daniel Measurement and Control, Inc. World Area Headquarters Houston, T exas, USA T : 713 -46 7-6 00 0, F : 71 3-8 27- 38 80 US A T oll Fre e 1- 888 -F LOW -0 01 ww w .d an iel .co m Calgary , Alberta, Canada T : 403 -27 9-1 87 9, F : 40 3-2 36- 13 37 Al ber ta T o ll F ree 1-8 00- 24 2-3 197 Sa les @Da ni eli nd- ca n.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Emerson TG-0807 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Emerson TG-0807 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Emerson TG-0807 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Emerson TG-0807 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Emerson TG-0807, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Emerson TG-0807.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Emerson TG-0807. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Emerson TG-0807 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.