45060A OWNER`S MANUAL DROLET EPA WOODSTOVES HT-1600 & HT-2000 US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVES Vérified and tested following ULC S627 et UL 1482 Standards by: READ AND KEEP THIS MANUAL FOR REFERENCE Manufactured by : STOVE BUILDER INTERNATIONAL INC.
1 TABLE OF CONTENTS INTRODUCT ION .................................................................................................................. .. 2 TECHNICAL SPECIF ICATION S ......................................................................
2 INTRODUCTION SBI INC ., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purc hase and wishes to help you get maximum satisfaction from your wood stove.
3 TECHNICAL SPECIFICATIONS HT-1600 HT-2000 Combustion Type: Wood Wood Recommended Surface 900 à 1 600 ft 2 1 000 à 2 000 ft 2 (84 à 149 m 2 ) (93 à 186 m 2 ) Heating Capacity : E.
4 TIPS ON WOOD HEATING Wood is a renewable energy. It is also a very clean heat source when used with appliances that are certified by the U.S. Environmental Protection Agency (EPA), a standard accepted in Canada as well. EPA-certified wood stoves are different than conventional w ood stoves.
5 ASSEMBLY PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION Pedestal Installation : 1. Remove all bricks and insulations in the appliance. 2. Slowly, lay down the stove on his back. 3. Install legs or the pedestal with the supplied nuts and bolts. Stand up the stove and plac e it with the required clearances.
6 BRICKS AND INSULATION INSTALLATION (HT-1600) 1. Remove from the stove all bricks and insulation. 2. Install all side bricks (11 x 4 1/2" x 9" & 1 x 4 ½” x 8 3/16" ) as shown in drawing below. 3. Install the back bricks (6 x 4 1/2" x 9") 4.
7 BRICK AND INSULATION INSTALLATION (HT-2000) The stove is normally supplied with secondary air t ubes in position. To install the baffle bricks and white ceramic insulation, it’s necessary to re move the two front secondary air tubes. First place only one baffle brick and one wh ite ceramic insulation.
8 AIR TUBES INSTALLATION (HT-2000): The secondary air tubes are painted different co lours . The back tube is yellow, the middle on is red and the front is unpainted. Before inst alling, make sure the locating holes in the tubes (holes near one end of the t ube) are on the left side.
9 DOOR ADJUSTMENT In order for your stove to operate properly, the door should be adjusted periodically to provide an air tight fit. To adjust: • Remove the lock pin (spring pin) by pulling and turn.
10 THE BENEFITS OF INSTALLING A BLOWER A blower can be installed at the back of your DRO LET stove. This option is necessary if you wish to redistribute into a room the heat trapped at the back of y our stove. By forcing hot air toward the front, the blower enables you to ex tend the radiation power of your stove.
11 INSTALLATION SAFETY NOTICE • I F THIS STOVE IS NOT PROPERLY INSTALLED , A HOUSE F IRE MAY RESULT . T O REDUCE THE RISK OF FIRE , FOLLOW THE INSTALLATION INSTRUCTIONS . F AILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE , BODILY INJURY , OR EVEN DEATH .
12 FLOOR PROTECTOR Your wood stove should be placed on a non-combustible surface. The floor protector should be under the stove, eighteen inc hes beyond the front and eight in ches beyond each side of the fuel loading and ash removal opening.
13 CLEARANCES It is of utmost importance that the clearanc es to combustible material be scrupulously respected upon installation of the stove you hav e selected. Refer to the tables below : Figure 6: Clearances to combustibles CANADA Single pipe / Double pipe Model A B C D E F HT-1600 15/12 16/16 12/10 20.
14 REDUCED CLEARANCES You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. Thes e heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-co mbustible sheet or a masonry wall.
15 CHIMNEY Your wood stove may be hooked up with a factor y built or masonry chimney. If you are using a factory built chimney, it must comp ly with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely im portant that it be inst alled according to the manufacturer's specifications.
16 CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have t he same diameter as the stove outlet. If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draught. The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.
17 TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING 18" CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIEL D Vertical installation.
18 MASONRY CHIMNEY: Cl ay l i ne r Thim b l e C l e an out door.
19 FACTORY BUILT THIMBLE:.
20 BRICK THIMBLE:.
21 WOODSTOVE UTILIZATION Your heating unit was designed to burn wood onl y; no other materials should be burnt. Wastes and other flammable materials should not be burnt in your wood st ove. Any type of wood may be used in your stove, but specif ic varieties have better energy yields than others.
22 Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split. The wood should not be stored dire ctly on the ground. Air should circulate through the cord. A 24" to 48" air space should be left between eac h row of logs, which should be placed in the sunniest location possible.
23 HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of com bustion you want for each given situation. The wood will burn slowly if the wood stove air intake control is adjusted to reduce the oxygen supply in the combustion chamber to a minimum.
24 RELOADING Once you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air controls to ma ximum a few seconds prior to opening the stove's door.
25 ASH DISPOSAL Ashes should be removed from the stove every fe w days or when ashes get to 2 to 3 inches deep. Always empty the stove when it is cold, such as in the morning.
26 MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require little maintenance. It is important to perform a visual ins pection of the stove every time it is emptied, in order to insure that no parts have been damaged, in which case repairs must be performed immediately.
27 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consum er purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, m odified nor repai red since shipm ent from factory.
28 Before shipping your unit or defective co mponent to our plant, you must o btain from your DROLET dealer an Authorization Number. Any merchandise shipped to our plant without authorization will be refused automatically and returned to sender.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Drolet 75281 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Drolet 75281 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Drolet 75281 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Drolet 75281 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Drolet 75281, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Drolet 75281.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Drolet 75281. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Drolet 75281 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.