Manuale d’uso / di manutenzione del prodotto PD758S 3/4 HP del fabbricante Chamberlain
Vai alla pagina of 40
The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1 196 www .chamberlain.com GARAGE DOOR OPENER Model PD758S 3/4 HP For Residential Use Only ® Owner’ s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation.
2 T ABLE OF CONTENTS When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.
3 T o prevent damage to garage door and opener: • AL WA YS disable locks BEFORE installing and operating the opener . • ONL Y operate garage door opener at 120V , 60 Hz to avoid malfunction and damage.
4 Safety Reversing Sensor Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 23 for details. Header Wall Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1/4" (6 mm).
5 Access Door Safety Reversing Sensor Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1/4" (6 mm). Door Bracket Straight Door Arm Garage Door CLOSED POSITION Header B.
6 Straight Door Arm Section Curved Door Arm Section Safety Labels and Literature 2-Conductor Bell Wire White & White/Red Idler Pulley Motor Unit with 2 Light Lenses Chain and Cable Hanging Bracket.
7 Master Link (2) Idler Bolt (1) Nut 3/8" (1) Trolley Threaded Shaft (1) Lock Washer 3/8" (1) Lock Nut 1/4"-20 (2) Wing Nut 1/4"-20 (2) Carriage Bolt 1/4"-20x1/2" (2) Han.
Clip Tapered End of Rail FRONT RAIL (TOP) KEEP LARGER HOLE ON TOP 8 ASSEMBL Y STEP 1 Assemble the Rail & Install the T rolley T o avoid installation difficulties, do not run the garage door opener until instructed to do so.
9 T o avoid SERIOUS damage to garage door opener , use ONL Y those bolts/fasteners mounted in the top of the opener . ASSEMBL Y STEP 2 Fasten the Rail to the Motor Unit • Insert a 1/4"-20x2-1/2 bolt, washer and spacer into the cover protection bolt hole on the back end of the rail as shown.
10 ASSEMBL Y STEP 4 Install the Chain/Cable 1. Pull the cable around the idler pulley and toward the trolley . 2. Connect the cable to the retaining slot on the trolley , as shown (Figure 1): • From below , push pins of master link bar up through cable link and trolley slot.
11 INST ALLA TION ASSEMBL Y STEP 5 Tighten the Chain • Spin the inner nut and lock washer down the trolley threaded shaft, away from the trolley . • T o tighten the chain, turn outer nut in the direction shown (Figure 1).
12 INST ALLA TION STEP 1 Determine the Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door . 1. Close the door and mark the inside vertical centerline of the garage door .
13 Lag Screws 5/16"x9x1-5/8" — Finished Ceiling — Door Spring Header Wall UP Ceiling Mounting Holes 6" (15 cm) Maximum Header Bracket Vertical Centerline of Garage Door Garage Door .
14 INST ALLA TION STEP 3 Attach the Rail to the Header Bracket NOTE: (Optional) With some existing installations, you may re-use the old header bracket with the two plastic spacers included in the hardware bag. Place the spacers inside the bracket on each side of the rail, as illustrated.
15 ONE-PIECE DOOR WITHOUT TRACK A 2x4 on its side is convenient for setting an ideal door-to-rail distance. • Remove foam packaging. • Raise the opener onto a stepladder . Y ou will need help at this point if the ladder is not tall enough. • Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
16 INST ALLA TION STEP 5 Hang the Opener Three representative installations are shown. Y ours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener .
17 T o prevent possible SERIOUS INJURY or DEA TH from electrocution: • Be sure power is not connected BEFORE installing door control. • Connect ONL Y to 24 VOL T low voltage wires.
18 INST ALLA TION STEP 7 Install the Lights • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install up to a 100 watt maximum light bulb in each socket.
19 INST ALLA TION STEP 9 Electrical Requirements T o avoid installation difficulties, do not run the opener at this time. T o reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
20 Invisible Light Beam Protection Area Sensor Beam 6" (15 cm) max. above floor Sensor Beam 6" (15 cm) max. above floor Facing the door from inside the garage INST ALLA TION STEP 10 Install .
21 DOOR TRACK MOUNT (RIGHT SIDE) Indicator Light Lens Lip Sensor Bracket Door Track FLOOR MOUNT (RIGHT SIDE) WALL MOUNT (RIGHT SIDE) Indicator Light Sensor Bracket Lens Extension Bracket (See Accessor.
22 Carriage Bolt 1/4"-20x1/2" Lens Wing Nut Figure 5 MOUNTING AND WIRING THE SAFETY SENSORS • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor . Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door .
23 Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit.
24 Header Wall Vertical Centerline of Garage Door Finished Ceiling Optional Placement of Door Bracket Header Bracket Door Bracket 2x4 Support For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
25 INST ALLA TION STEP 12 Connect Door Arm to T rolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONL Y • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley .
26 ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
27 ADJUSTMENT STEP 1 Adjust the UP and DOWN T ravel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down. T o operate the opener , press the Door Control push bar . Run the opener through a complete travel cycle.
28 ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the right panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door . If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction.
29 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSL Y INJURED or KILLED by a closing garage door . • Safety reversal system MUST be tested ever y month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
30 OPERA TION Using Y our Garage Door Opener Y our Security ✚ ® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Y our opener will operate with up to eight Security ✚ ® remote controls and one Security ✚ ® Keyless Entry System.
31 T o Open the Door Manually DISCONNECT THE TROLLEY : The door should be fully closed if possible. Pull down on the emergency release handle (so that the trolley release arm snaps into a vertical position) and lift the door manually .
32 CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 27 and 28 refer to the limit and force adjustments.
33 HA VING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • V erify the safety sensors are properly installed, aligned and free of any obstructions.
34 Installed Safety Sensor Safety Sensor Bell Wire LED or Diagnostic LED "Learn" Button KG 1 3 9 7 5 KG 1 3 9 7 5 Diagnostics Located On Motor Unit Y our garage door opener is programmed with self-diagnostic capabilities.
*3-Button Remotes If provided with your garage door opener , the large button is factory programmed to operate it. Additional buttons on any Security ✚ ® 3-Button remote or compact remote can be programmed to operate other Security ✚ ® garage door openers.
1. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER. 2. While holding the ENTER button, press and hold the LIGHT button on the Multi-Function Door Control.
7 10 12 5 N O TIC E 6 4 3 2 9 13 8 1 11 LO C K L IG H T 3 1 5 4 2 6 Installation Parts 37 REP AIR P ARTS Rail Assembly Parts KEY P ART NO. NO. DESCRIPTION 1 4A1008 Master link kit 2 41C5141-1 Complete.
Motor Unit Assembly Parts 38 DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSEMBLY Grey Wire Yellow Wire (Up) Contact Center Limit Contact Drive Gear 2 4 3 1 14 18 8A 16 5 17 9 10 15 13 12 6 6 11 8B 8C 7 7 KEY P ART NO. NO. DESCRIPTION 1 41A5615 Chain Spreader 2 41A5585 Gear and sprocket assembly .
39 ACCESSORIES LOCK LIGHT C L O S E D O P E N SECURITY ✚ ® Keyless Entry: Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons.
© 2004, The Chamberlain Group, Inc. 1 14A2967C All Rights Reserved Printed in Mexico HOW T O ORDER REP AIR P ARTS Selling prices will be furnished on request, or parts will be shipped at prevailing prices and you will be billed accordingly .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Chamberlain PD758S 3/4 HP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Chamberlain PD758S 3/4 HP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Chamberlain PD758S 3/4 HP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Chamberlain PD758S 3/4 HP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Chamberlain PD758S 3/4 HP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Chamberlain PD758S 3/4 HP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Chamberlain PD758S 3/4 HP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Chamberlain PD758S 3/4 HP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.