Manuale d’uso / di manutenzione del prodotto EKI-2741LX del fabbricante Advantech
Vai alla pagina of 32
EKI-2741F 10/100/1000Bas e-T to SFP (mini-GBIC) Type Fiber Optic Media Converter EKI-2741SX 10/100/1000Bas e-T to 1000Base-SX SC Type Fiber Optic Media Converter EKI-2741LX 10/100/1000Bas e-T to 1000B.
EKI-2741F-SX-LX User Manual ii Copyright The documentation and the software i ncluded wi th this product are copyrighted 2007 by Advantech Co., Ltd. All rights ar e reserved. Advantech Co., Ltd. reserves the right to mak e improvements in the pro ducts describe d in this ma nual at any time without noti ce.
iii Product Warranty (2 years) Advantech warrants to you, the or igina l purchaser, that each of its products will be fre e from defects in materials and workmanshi p for two years from the date of purchase.
EKI-2741F-SX-LX User Manual iv Declaration of Conformity CE This product has passed the CE test for envir onmental spe cifications. Test conditions for passing included the equipment being operated within an indust rial enclosure.
v Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC out let before clea ning. Use a damp cloth. Do not use liquid or spray detergents for clean ing.
EKI-2741F-SX-LX User Manual vi Safety Precaution - Static Electricity Follow these simple precautions to protect your self from harm and the produ cts from damage. 1. To avoid electrical shock, always di sconnec t the power from your PC chassis before you work on it.
vii Contents Contents Chapter 1 Overview ........................................... 2 1.1 Introduction ......................................................... 2 1.1.1 Fast Fiber Converters Module ................... 2 1.1.2 Dual Power Input .......
EKI-2741F-SX-LX User Manual viii.
1 Chapter1 Overview Sections include: z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER.
EKI-2741F-SX-LX User Manual 2 Chapter 1 Overview 1.1 Introduction The EKI-2741 is designed to convert Gi gabit Ethernet networks to Gigabit fiber networks by transparently converting Ethern e t signals to optic sig nals. The advantages of fiber optics are wide bandwidth, EMI immunity and long-distan ce transmission capability.
3 Chapter1 1.2 Features • Provides 1 x SFP (mini-GBIC) type connector (EKI-2741F) • Provides 1 x 1000Base-SX or 1000Base-LX SC type connector (E KI-2741SX/LX) • Provides 1 x 10/100/1000Mbps Ethe.
EKI-2741F-SX-LX User Manual 4 1.3 Specification Communications Standard IEEE 802.3, 802.3ab, 802.3u, 802.3x, 802.3z LAN 10/100/1000Base-TX, 1000Base -SX, 1000Base-LX Transmission Distance Multi-Mode F.
5 Chapter1 Environment Operating Temperature -10 ~ 60 ℃ (14~140 ℉ ) Wide temp. model: -40 ~ 75 ℃ (-40 ~ 167℉) Storage Temperature -40 ~ 85 ℃ (-40 ~ 185 ℉ ) Operating Humidity 5 ~ 95% (non-conde nsing) Storage Humidity 0 ~ 95% (non-condensi ng) Certifications Safety UL, 60950-1, CAN/CSA-C22.
EKI-2741F-SX-LX User Manual 6 1.4 Packing List • 1 x EKI-2741F or EKI-2741SX or EKI -2741LX Industrial Ethernet Switch • 1 x eAutomation Industrial Communication CD-ROM with software, and User m a.
7 Chapter2 Installation Sections include: z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER.
EKI-2741F-SX-LX User Manual 8 Chapter 2 Installation In this chapter, you will be given an over view of the EKI-2741F/SX/LX hardware installation procedures.
9 Chapter2 2.2 DIP-Switch The DIP-Switch is used to config ure operation mode for LFP ( Link Fault Pass- Through ) and operation mode for UT P/Fiber port.
EKI-2741F-SX-LX User Manual 10 2.3 Dimensions (units: mm) Figure 2.1: Front View of EKI-2741 series.
11 Ch apter2 Figure 2.2: Side View of EKI-2741 series.
EKI-2741F-SX-LX User Manual 12 Figure 2.3: Rear View of EKI-2741 series.
13 Ch apter2 The terminal block of power & relay is located o n the top side. Please refer to page 16 for pin assignment. Figure 2.4: Top View of EKI-2741 series.
EKI-2741F-SX-LX User Manual 14 2.4 Mounting The EKI-2741F/SX/LX support two mounting methods: DIN-rail & Wall. 2.4.1 Wall mounting EKI-2741F/SX/LX can be wall-mounted by using the included mou nting kit. Then, hang on the EKI-2741F/SX/LX to the nails on the wall.
15 Ch apter2 2.4.2 DIN-rail Mounting You can also mount EKI-2741F/SX/LX on a standard DIN-rail by below steps. The DIN-rail kit is screwed on the industrial sw itch when out of factory. If the DIN-rail kit is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.
EKI-2741F-SX-LX User Manual 16 Then, let the device down straight to slide over the rail smoothly. See Figure 2.7 Figure 2.7: Installation to DIN-rail Step 2.
17 Ch apter2 2.5 Network Connection • Twisted-pair segment can use unshielded tw isted pair (UTP) or shi elded twisted pair (STP) cabling. The cable between the lin k pa rtner (switch, hub, workstation, etc.) and the converter, mu st be less than 100 meters (328 ft.
EKI-2741F-SX-LX User Manual 18 Second, insert the fiber cable of LC conn ector into the transceiver. Figure 2.10: LC connector to the transceiver To remove the LC connector from the trans ceiver, please follow the step s shown below: First, press the upper side of the LC con nector fr om the transceiver and pull it out to release.
19 Ch apter2 Second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: Pull out from the SFP module.
EKI-2741F-SX-LX User Manual 20 2.6 Power Connection The EKI-2741F/SX/LX support dual +12 ~ 48 V DC power inputs a nd power-fail relay output. Figure 2.13: Pin Assignment of the Power Connecto r You can connect an alarm i ndicator, buzzer or other signalin g equipment through the relay output.
21 Ch apter2 Troubleshooting CHAPTER.
EKI-2741F-SX-LX User Manual 22 Chapter 3 Troubleshooting 1. Power Input Verify that is using the right power cord/ada pter (+12~48 V DC ), please don’t use the power adaptor with DC o utput voltage higher than 48V, or it will burn this converter down.
23 Ch apter2 Pin Assignment & Wiring APPENDIX.
EKI-2741F-SX-LX User Manual 24 Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Advantech EKI-2741LX è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Advantech EKI-2741LX - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Advantech EKI-2741LX imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Advantech EKI-2741LX ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Advantech EKI-2741LX, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Advantech EKI-2741LX.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Advantech EKI-2741LX. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Advantech EKI-2741LX insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.