GUARANTEE

  • This appliance is for domestic use only; any misuse or use that does not conform to the instructions will release the brand from all liability and the guarantee will be cancelled.
  • Read the instructions for use carefully before using your appliance for the first time: use that does not conform to the instructions will release Rowenta from all liability.

SAFETY INSTRUCTIONS

For your safety, this appliance complies with all applicable standards and regulations (Low Voltage 2006/95/EC, Electromagnetic Compatibility 2005/108/EC, Environmental directives, etc.).

Keep the appliance and its cord out of reach of children less than 8 years old. Children under the age of 8 years should not use this appliance unless continuous supervision by a responsible adult is given.

1 • Terms and conditions for use Your vacuum cleaner is an electrical appliance: is should be used under normal conditions for use. Use and store the appliance out of the reach of children. Never leave the vacuum on unsupervised. Do not place the nozzle or the end of the tube near the eyes or ears. Do not vacuum wet surfaces, any type of liquids, hot substances, supersmooth substances (platinum, cement, ash, etc.), large sharp waste (glass), harmful products (solvants, abrasives, etc.), aggressive products (acids, cleaning products, etc.), inflammable and explosive products (oil or alcohol based). Never immerse the appliance in water; do not spill water on the appliance and do not store it outside. Do not use the appliance if: it has been dropped and there is visible damage or it fails to function correctly. In this case, do not open the appliance but send it to the nearest Approved Service Centre or contact Rowenta Customer Services. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.

2 • Power supply Check that your vacuum cleaner voltage corresponds to that of your domestic power supply. Switch off and disconnect the appliance by unplugging without pulling the cord: immediately after use, before changing accessories, before cleaning, maintenance or changing the filter. Do not use the appliance if the power cord is damaged. The cord winder and cord for your vacuum cleaner must be replaced by an Approved Service Centre as special tools are required for repairs to avoid any risks.

Important: the mains socket outlet should be protected with a 16 A fuse at least. If the circuit breaker is triggered while the appliance is in operation, this may be due to the fact that other appliances with high connected power are connected at the same time to the same electrical circuit. This can be avoided by setting the appliance to a low power before turning on and then adjusting to a higher power.

3 • Repairs Repairs should only be performed by a Rowenta Approved Service Centre. Repairs carried out by the user can pose a risk and cancel the guarantee.

DESCRIPTION

1 Cover 2 Cover release button 3 Front cover 4 Air/dust separation system a - Cone separator b - Air/dust separation grille c - Separation compartment 5 Dust compartment a - Main compartment b - Fine dust compartment c - Dust compartment seals 6 Maximum fill level for dust compartment 7 Dust compartment housing 8 Carrying handle 9 Suction inlet

10 Air outlet grille 11 ON/OFF button 12 Power cord wind button 13 Parking positions 14 Wheels 15 Multi-direction wheel 16 a - HEPA filter housing 16 b - HEPA filter access hatch 17 HEPA Filter, cccording to model : a - HEPA* Filter (ref ZR9020.01) b - HEPA* washable filter (ref RS-RT3733) 18 Filtration cassette (ref RS-RT3732) a - Black foam filter b - Microfilter 19 Filtration cassette detection system (18)

* According to model: these systems are specific to certain mo- dels or are accessories available as an option.

Page 3 of the Rowenta RO7834 COMPTACT FORCE CYCLONIC user manual — USE
Pagina 3 · clicca per ingrandire
Pagina 3

DESCRIPTION

Accessories 20 Flexible hose with power nozzle ERGO COMFORT (21) 21 a - ERGO COMFORT ergonomic nozzle b - Integrated brush (EASY BRUSH) c - Manual power switch (POWER CONTROL) 22 ERGO COMFORT metal telescopic tube a - Nozzle/tube locking system (LOCK SYSTEM) b - Tube adjustment button (TELESCOPIC SYSTEM) 23 ERGO COMFORT multi-surface nozzle a - Nozzle/tube locking system (LOCK SYSTEM)

b - 2-position button: brush retracted for rugs and carpets/brush released for parquet and smooth floors 24 Telescopic crevice nozzle* 25 Upholstery nozzle* 26 Delta parquet nozzle* 27 Rectangular parquet nozzle* 28 Turbo-brush* 29 Mini turbo-brush* 30 Accessory support*

BEFORE FIRST USE

1 • Unpacking Unpack your appliance and remove any labels, keep your warranty form and read the instructions carefully before using your appliance for the first time.

Do not use the power cord or the hose to lift the appliance. Switch off and unplug your vacuum cleaner after each use. Always switch off and unplug your vacuum cleaner before maintenance or cleaning. Your vacuum cleaner is fitted with a safety device which prevents the motor from overheating. In certain cases (when used on chairs, sofas, etc.) the safety device may be tripped and the appliance may make an unusual noise that is not serious. Only use original Rowenta accessories and filters. Check that all the filters are in place. Do not operate your vacuum cleaner without the filtration system fitted (foam, microfilter and filter). Never place the foam and microfilter in the appliance unless they are completely dry. If you have any difficulties in finding accessories or filters for this vacuum cleaner, contact the Rowenta Customer Service.

2 • Recommendations and precautions Unwind the power cord completely before each use. Do not jam it and do not allow it to rub against sharp edges. If you are using an electrical extension, check that it is in perfect condition and that it is suited to the power of your vacuum cleaner. Do not unplug the appliance by pulling on the power cord. Do not move the vacuum cleaner by pulling on the power cord, the appliance must be moved using its carrying handle.

USE

1 • Fitting the elements onto the appliance

- For rugs and carpets: use the multi-surface nozzle in the retracted brush nozzle position or the Turbo-brush* (fibres and animal hairs). - For parquet and smooth floors: use the multi-surface nozzle in the brush release position or for best results use the parquet nozzle*. - For corners and hard to reach spots: use the telescopic crevice nozzle*. - For upholstery and delicate surfaces: use the brush with the nozzle (EASY BRUSH) or the upholstery nozzle*.

Clip the end of the hose to the suction inlet located at the front of the appliance (fig.1). To remove, unclip the end using the clip and remove. Fix the accessory support to the notch in the parking position located at the back of the vaccuum cleaner (fig.2) and store the accessories on top.

ERGONOMIC RECOMMENDATIONS ERGO COMFORT range Ergonomic, the ERGO COMFORT range has been designed to facilitate and improve user comfort when vacuuming. To prevent bending over and to ensure upright posture, make sure to: 1. Adjust the length of the ERGO COMFORT metal telescopic tube to your body (fig.6). 2. Place your second hand on the front of the ERGO COMFORT nozzle handle (fig.7).

  • Fit the metal telescopic tube to the end of the nozzle until you hear a click indicating that it is locked (fig.3). To remove, press the tube lock button and remove.
  • Fit the multi-surface nozzle (23) to the end of the metal telescopic tube until you hear a click indicating that it is locked (fig.4). To remove, press the nozzle lock button and remove.
  • Adjust the metal telescopic tube to the desired length using the telescopic system (TELESCOPIC SYSTEM) (fig.5). Fit the corresponding accessory to the end of the metal telescopic tube or the nozzle:

* According to model: these systems are specific to certain mo- dels or are accessories available as an option.

Page 4 of the Rowenta RO7834 COMPTACT FORCE CYCLONIC user manual — CLEANING AND MAINTENANCE
Pagina 4 · clicca per ingrandire
Pagina 4

USE

2 • Plugging in the power cord and switching on the appliance

3 • Storing and transporting the appliance

Unwind the power cord completely, plug in your vacuum cleaner and press the ON/OFF button (fig. 8).

After use, switch off your vacuum cleaner by pressing the ON/OFF button and unplug it (fig. 10). Wind the power cord by pressing the power cord wind button (fig. 11). It is easy to carry your vacuum cleaner using the handle (8). Do not carry your appliance using the dust compartment handle (fig.12). When storing your vacuum cleaner, place the tube in its storage compartment at the back of the appliance (fig.13). You do not need to remove the accessory support (30) to store the accessory range (Fig.14).

  • Set the suction power using the manual power switch* on the power nozzle (fig.9):
  • Position (MIN) for vacuuming delicate fabrics (curtains, textiles).
  • Position (Medium) for daily vacuuming of all types of surfaces with low levels of soiling.
  • Position (MAX) for vacuuming hard floors (tiled floors, parquet, etc.) and rugs and carpets in the case of high levels of soiling.

CLEANING AND MAINTENANCE

2 • Cleaning the black foam filter (18a)

The air we breathe contains particles that can be allergenic: larva and dust mite faeces, mould, pollen, smoke and animal waste (hair, skin, saliva, urine), etc. The finest particles can penetrate deep inside the respiratory system or can cause inflammation and affect the entire respiratory system. (H)EPA ([High] Efficiency Particulate Air Filter) filters retain the finest particles. Thanks to the (H)EPA filter, the air released into the room is cleaner than the air suctioned.

Press the cover release button (fig.21). Tip the cover backwards (fig.22). Remove the black foam filter (fig.23) then wash and squeeze it (fig.24). Leave to dry for at least 12 hours before refitting.

Reposition the black foam filter and close the cover. 3 • Cleaning the microfilter (18b)

1 • Emptying the dust compartment (5) After each use, empty the dust compartment as follows: Take the dust compartment by the handle and remove it (fig.15). Separate the fine dust compartment (5b) from the main compartment (5a) (Fig.16). Empty the main compartment over a dustbin (Fig.17) then empty the fine dust compartment (5b) (Fig.18). Clean the compartment seals using a cloth. Reposition the fine dust compartment on the main compartment (Fig.19) then put the dust compartment back into place (fig.20).

Press the cover release button (fig.21). Tip the cover backwards (fig.22). Remove the filtration cassette (18) then separate the black foam filter (18a) from the microfilter (18b) (fig.25). Wash the microfilter (fig.26). Leave to dry for at least 12 hours before refitting.

Reposition the black foam filter and close the cover.

* According to model: these systems are specific to certain mo- dels or are accessories available as an option.

Page 5 of the Rowenta RO7834 COMPTACT FORCE CYCLONIC user manual — TROUBLESHOOTING
Pagina 5 · clicca per ingrandire
Pagina 5

CLEANING AND MAINTENANCE

truly dry before putting it back in place). Put the HEPA filter back in its compartment (Fig.32). Push the hatch back until you hear a locking click.

The washable HEPA filter* ref RS-RT3733 is available at shops or at Approved Service Centres.

The filtration cassette ref. RS-RT3732 (18a+18b) is available from shops or at Approved Service Centres.

6. Cleaning the air/dust separator system (4) Remove the hose from the vacuum cleaner. Open the vacuum cleaner cover (fig. 21-22). Press the separator release button (fig.33) then remove from the separation system (fig.34). Remove the separation compartment (4c) by turning slightly to the left (fig.35) then separate the two components (fig.36). Wash the components (4a+b and 4c) in clear water (fig. 37) and leave to dry for 6 hours. Refit the filter system components (4): - Reposition the separation compartment (4c) on the separation system (4a+b) (fig. 38) by turning slightly until you hear the click indicating that it is closed (fig. 39). - Then reposition the entire separation system (4) in the appliance (fig. 40) and close the cover.

4 • Cleaning the HEPA filter (17) If necessary, remove the accessory support (30)* then place the vacuum cleaner in the vertical position (Fig.27). Open the HEPA filter hatch (Fig.28). Remove the HEPA filter from its housing (fig.29). Clean the HEPA filter by gently patting it over a dustbin (fig. 30). Reposition it in its housing (Fig.32). Reposition the hatch until you hear a click indicating that it is closed.

7 • Cleaning your vacuum cleaner Wipe the body of the vacuum cleaner and accessories with a soft damp cloth, then dry with a dry cloth. Wash the dust compartment (5a+ 5b) under clear or soapy water, then dry with a dry cloth.

5 • Wash the washable HEPA filter * ref. RS-RT3733* (17b)

If necessary remove the accessory support (30)* then place the vacuum cleaner in the vertical position (Fig.27). Open the HEPA filter access hatch (Fig.28) Remove the HEPA filter from its compartment (fig.29). Tap the HEPA filter whilst holding it over a dustbin (Fig.30), then pass it under some running water and leave it to dry for at least 24 hours (Fig.31) (make sure that the filter is well and

TROUBLESHOOTING

HEPA filter is damaged, replace it. • Filtration cassette (ref RS-RT3732): clean the black foam filter (18a) and the micro filter (18b) as indicated in the procedure.

If your vacuum cleaner will not start • The appliance is not powered. Check that the appliance is plugged in correctly.

  • If your vacuum cleaner has less suction power, is noisy or makes a whistling noise
  • An accessory, the tube, hose, separator (4a), air/dust separation grille (4b) or the separation compartment (4c) is partially blocked: unblock them.
  • The dust compartment is full: empty and wash it.
  • The vacuum cleaner cover is not fitted correctly: close properly.
  • The dust compartment is not correctly fitted: fit it correctly.
  • The nozzle's manual power switch* is open: close it.
  • If your vacuum cleaner has no suction power
  • An accessory, the tube, hose, separator (4a), air/dust separation grille (4b) or the separation compartment (4c) is blocked: unblock them.
  • Clean the HEPA filter ref ZR9020.01* (17a) as indicated in the procedure and put it back in its compartment or wash the washable HEPA filter ref RS-RT3733* (17b) following the procedure shown and put it back in its compartment. If the

* According to model: these systems are specific to certain mo- dels or are accessories available as an option.

Page 6 of the Rowenta RO7834 COMPTACT FORCE CYCLONIC user manual — Think of the environment!
Pagina 6 · clicca per ingrandire
Pagina 6

TROUBLESHOOTING

  • If the cone separator (4a) fills up
  • Dust accumulates in the separation compartment (4c): Check that the pipe between the separator (4c) and the dust compartment (5) is not blocked. Check that nothing is obstructing the dust compartment inlets.
  • The dust compartment inlets are blocked: remove the dust compartment and empty it. Clean the dust compartment seals.

If the power cord does not wind completely • The cord slows down as it winds up: pull the power cord out again and press the power cord wind button.

In the event of a persistent problem, take your vacuum cleaner to your nearest Rowenta Approved Service Centre or contact Rowenta Customer Services.

If it is difficult to move the nozzle • Open the manual power switch* on the nozzle.

WHERE TO BUY ACCESSORIES

Rowenta RO7834 COMPTACT FORCE CYCLONIC — WHERE TO BUY ACCESSORIES diagram (page 6)
Fig. 1

Upholstery brush For cleaning upholstery. Attach the upholstery brush to

Upholstery nozzle For cleaning upholstery. Fit the upholstery nozzle to the end of the nozzle or tube.

Fit the telescopic crevice nozzle to the end of the nozzle or tube.

For delicate floors. Fit the parquet nozzle to the end of the tube

DELTA parquet nozzle For delicate floors. Fit the DELTA parquet nozzle

Turbo-brush For removing animal hairs and fibres embedded in rugs

Fit the turbo-brush to the end of the tube.

DISPOSAL/ENVIRONMENT

Packaging: the packaging protecting your appliance consists of environment-friendly and recyclable materials. Packaging that is no longer used should be disposed of at specially designated collection points.

Think of the environment!

Used filters: as they do not contain forbidden substances in terms of household waste, the used filters can be disposed of with household waste.

The used appliance: do not dispose of your appliance with household waste. Your appliance contains numerous valuable or recyclable materials and therefore should be given to a dealer or a recycling centre for disposal.

* According to model: these systems are specific to certain mo- dels or are accessories available as an option.

Fai una domanda su Rowenta RO7834 COMPTACT FORCE CYCLONIC

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Rowenta RO7834 COMPTACT FORCE CYCLONIC

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Rowenta RO7834 COMPTACT FORCE CYCLONIC manuale in PDF

60 pagine·8.3 MB·Aspirapolvere·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…