for wear and possible damage. Check for signs of rust, corrosion or fractures. The door system may not be used if repair or adjustment work needs to be carried out. Always remember that a fault in the door system or a misaligned door can also cause injury.
Thank you for choosing this quality product from our company. Please keep these instructions safe for later reference!
Please observe the following instructions, they provide you with important information on the safe installation and use of your Garage Door Operator, thus ensuring that this product will give you satisfaction for many years to come.
1.2 Important instructions for safe installation Any further processing must ensure that the national regulations governing the operation of electrical equip- ment are complied with.
1.1 Important safety instructions This garage door operator is designed exclusively for the automated operation of spring-balanced up-and-over and sectional doors in the non-commercial sector. Use in the commercial sector is not permitted.
1.2.1 Before installing the garage door operator, check that the door is in a good mechanical condition and is correctly balanced. Further check whether the door opens and closes in the proper manner (see section 1.1.2). In addition, any of the door's mechanical locks and latches not needed for power operation of the garage door should be immobilised. This includes in particular any locking mechanisms connected with the door lock (see sections 2.2 to 2.3).
1.1.1 We shall be exempt from our warranty obligations and product liability in the event that the customer carries out his own structural changes or undertakes improper installation work or arranges for same to be carried out without our prior approval and contrary to the installation guidelines we have provided. Moreover, we shall accept no responsibility for the in- advertent or negligent operation of the operator and accessories nor for the improper maintenance of the door and/or its counterbalance mechanism. Batteries and light bulbs are also not covered by the warranty.
The garage door operator is designed for use in dry buil- dings and therefore may not be installed outdoors. The garage ceiling must be constructed in such a way as to guarantee safe, secure anchoring of the operator. In the case of ceilings that are too high or too lightweight, the operator must be attached to additional braces.
1.2.2 In carrying out the installation work the applicable regulations regarding working safety must be complied with.
1.1.2 Checking the door / door system The design of the operator is not suitable nor intended for the opening and closing of heavy doors, i.e. doors that can no longer be opened or closed manually. Before installing the operator, it is therefore necessary to check the door and make sure that it can also be easily moved by hand. To do this, raise the door approx. 1 metre and then let it go. The door should retain this position, moving neither up nor down. If the door should move in any of the two directions, there is a risk that the compensating springs are defective or incorrectly adjusted. In this case increased wear and malfunctioning of the door system can be ex- pected.
The clearance between the highest point of the door and the ceiling (also when the door is opening) must be at least 30 mm (see fig. 1.1a / 1.1b). If there is inadequate clearance, the operator may also be installed behind the opened door, provided sufficient space is available. In such instances an extended door link arm must be used. The garage door operator can be positioned off-centre by max. 50 cm, the exception being sectional doors with high-lift tracks (track application "H"), where a special track fitting is required.
The required shockproof electric socket allowing the ope- rator to be connected to the electricity supply should be installed at a distance of approx. 50 cm from the operator head. Please check these dimensions!
In addition, check the entire door system (pivots, door bearings, cables, springs and fastenings)
Dear Customer, · 1 Important Notes · ➤

Some of the figures also include the symbol shown below together with a text reference. This refers to specific text in the ensuing text section to provide you with important information regarding installation and operation of the garage door operator.

Example:
Permanently installed controls (such as buttons or similar devices) should be installed within sight of the door but well away from any moving parts and at a height of at least 1.5 metres. It is vital that they are installed out of the reach of children!
= see text section, point 2.2
on the carriage cannot get caught up in the ceiling's support system or in any other protruding parts of vehicles or the door.
1.4 Maintenance advice The garage door operator is maintenance-free. For your own safety, however, we recommend that you have the door system checked once a year by service engineers qualified to inspect and service garage doors.
1.5 Information on the illustrated section The illustrated section shows installation of the operator on an up-and-over door. Where installation differs for a sectional door, this is shown in addition. In this instance, letters are assigned to the figures as follows: O a is assigned to the up-and-over door and O b to the sectional door.

3.1 Establishing the door's end-of-travel positions by installing the limit stops 1) Insert the limit stop for the OPEN end-of-travel loosely into the boom between the carriage and the drive unit (see figure 4) and after fitting the door link (see figure 6.1a / 6.2a / 6.1b / 6.2b) push the door by hand into the OPEN end-of-travel position ➜the limit stop is pushed into the correct position (see figure 7). 2) Fix the limit stop for the OPEN end-of-travel position. 3) Insert the limit stop for the CLOSE end-of-travel loosely into the boom between the carriage and the drive unit (see figure 4) and push the door by hand into the CLOSE end-of-travel position ➜the limit stop is pushed close to the correct position (see figures 8). 4) Push the limit stop for the CLOSE end-of-travel position approx. 1 cm further in the CLOSE direction and then fix in place.
2.1 Required clearance for installing the operator When installing the operator, the clearance between the door at its highest point of travel and the ceiling must be at least 30 mm (see figures 1.1a / 1.1b).
2.2 The mechanical door latches on an up-and-over door must be immobilised (see figure 1a). In the case of door models not listed here, the catches must be locked on site.
2.3 On a sectional door the internal mechanical latch must be completely dismantled (see figure 1b).
2.4 Note Up-and-over doors with a forged iron door handle Contrary to the illustrated section (see figure 2a / 3.2a), these doors require the lintel bracket fastening and the door link bracket to be fitted off-centre.
3.2 Notes on work involving electrics
2.5 Central handle on a sectional door For sectional doors with a centrally positioned handle, fit the lintel bracket fastening and the door link bracket off- centre (see figure 2b).
- Electrical connections may only be made by a
2.6 Off-centred reinforcement profile on a sectional door In the case of an off-centred reinforcement profile on a singleskin sectional door, fit the door link bracket to the nearest reinforcement profile on the left or right (see figure 2b).
qualified electrician! - Onsite electrical installation must comply with
the relevant safety regulations (230/240 V AC, 50/60 Hz)! - Before working on the operator, always unplug
from the mains! - External voltage at any of the controls connecting
terminals will completely destroy the electronics (exception terminal .6, .5, .8)! - To avoid malfunctions, ensure that the control
cables of the operator (24 V DC) are laid in an installation system separate to other supply lines (230 V AC)!
2.7 Tensioning the drive belt The operator boom’s toothed belt is already set at the factory for optimum tension. During the starting and braking phases of large doors it can happen that the belt hangs out of the boom profile temporarily. This, however, is of no technical disadvantage nor does it have any negative effect on the operator's function and service life.
3.3 Electrical connection
3.3.1 Installation layout (see figure 10)
3.3.2 Operator wiring diagram (see figure 11)
3.3.3 Connecting terminals (see figure 12 / 12.2) The connecting terminals are accessible on removing the back cover (head piece).
3 Putting into Service / Connecting Additional Components / Operation
3.3.4 Operator lighting (see figure 12.1) Replacement bulb E14 230 V / 40 W / R50
2 Installation Instructions

3.3.5 Connecting the remote control The remote control is to be connected as follows: Plug-in connection (see figure 13) The receiver unit plug is plugged into the corresponding plug-in location on the operator head. There is no need to remove the cover to do this. The decimal point glows for as long as the impulse is generated via the radio receiver.
3.4.5 Connecting an OFF-switch or a wicket door contact (opening must be forcibly actuated) to halt and/or switch off the operator (STOP or emergency-OFF circuit) An OFF-switch with normally closed (n.c.) contacts (switching to 0 V or potential-free) is connected as fol- lows (see figure 18): 1) The jumper inserted at the factory between terminal 12 (STOP or emergency-OFF input) and terminal 13 (0 V), allowing normal function of the operator, should be removed. 2) - Switching output or first contact at terminal 12 (STOP or emergency-OFF input). - 0 V (Ground) or second contact to terminal 13 (0 V).
When a hand transmitter / receiver set is included, the top button on the hand transmitter is generally already pro- grammed into the receiver. For information on how to programme in hand transmitter buttons on other receivers, please refer to the instructions supplied with the receiver.
Note Completely unroll the throw-out aerial and fasten to the garage ceiling, if possible upwards as well as diagonally to and in the direction of the structural opening. In doing so, do not wind the aerial wire around metal parts such as nails, braces etc. The best alignment to achieve an optimum range must be established by trial and error. 868 MHz: GSM 900 mobile phones used at the same time may influence the range of the radio remote control.
3.4.6 Connecting a photocell Photocells switching to ground (0 V) must be connected as follows (see figure 19):
Connection Terminal Ground (0 V) 20 Switching output signal 71 Test input (optional) 18 Supply (+24 V) 5
3.4 Connecting of the additional components
3.4.1 Connecting external IMPULSE buttons to start or stop door travel cycles One or several buttons with normally open (n.o.) contacts (potential-free), such as internal buttons or key switches, is/are connected (in the case of the latter, then joined parallel) as follows (see figure 14): 1) first contact to terminal 21 (impulse input). 2) second contact to terminal 20 (0 V). The decimal point glows for as long as the impulse is generated via the button.
When the light path is clear, the switching output (signal) = 0 volts. With photocells without a test input, do not connect terminal 18. After activation of the photocell, the operator stops and causes the door to travel to the top end-of-travel position (safety return).
3.4.7 Connecting a closing edge safety device Closing edge safety devices switching to ground (0 V) must be connected as follows (see figure 20):
3.4.2 Connecting an external “OPEN“ button An external “OPEN“ button can be connected to terminals 15 and 14 (see figure 15). 1) first contact to terminal 15 (impulse input). 2) second contact to terminal 14 (0 V).
Connection Terminal Ground (0 V) 20 Switching output signal 19 Test input (optional) 18 Supply (+24 V) 5
3.4.3 Connecting an external “CLOSE“ button An external “CLOSE“ button can be connected to ter- minals 17 and 14 (see figure 16). 1) first contact to terminal 17 (impulse input). 2) second contact to terminal 14 (0 V).
When the light path is clear, the switching output (signal) = 0 volts. With closing edge safety devices without test input, do not connect terminal 18. After activation of the closing edge safety device, the operator stops and raises the door a short distance.
3.4.8 Connecting to the options relay The potential-free contacts of the options relay allow con- nection, for example, an external light or a warning light without automatic flashing (see figure 21). To feed an external light, external voltage must be used!
3.4.4 Connecting a light switch (potential-free) An external potential-free switch allowing the operator lighting to be switched on/off can be connected to ter- minals 10 and 20 (see figure 17).
Terminal .6 n.c. contact max. contact load: Terminal .5 common contact 2,5 A / 30 V DC Terminal .8 n.o. contact 500 W / 250 V AC ➤

Teaching the travel limits (see figure 24) (attention: the carriage must be engaged! ➜ See figure 22) Switch the control system, if necessary, to the learning mode by pressing the PRG button to change to menu 1. After the “1“, a flashing “L“ is now displayed. First press the OPEN button () to allow the door to open right up to its mechanical limit stop. Then press the CLOSE button (). On reaching the CLOSE travel limit, the door automatically carries out a complete opening cycle. Complete at least three uninterrupted open-close door cycles. The system is then ready for operation.
4 Putting the operator into service
4.1 Normal Operation During normal operation the garage door operator works on impulse repetition control which is triggered via an external button or a programmed-in hand trans mitter button: 1st impulse : door travels in the direction of an end-of- travel position 2nd impulse: door stops 3rd impulse : door travels in the opposite direction 4th impulse : door stops 5th impulse : door travels in the direction of the end-of- travel position selected with the first impulse etc. The operator lighting comes on whilst the door is moving and automatically goes out 3 minutes later on completion of the cycle. The display´s desmo point will light during impuls output from the receiver/button.
4.4.3 Operation following a power failure In the event of a power failure, the stored door data is retained. However, the door must then be allowed to complete one full opening cycle (reference travel cycle) to ensure the correct function. During this reference travel cycle it is important that the belt carrier is engaged in the carriage. If this is not the case, the belt carrier will travel into the drive wheel, and the operator will then register this as its reference point. If this should happen, allow the operator to travel in the CLOSE direction until you can engage the belt carrier in the carriage. After isolating the operator from the mains, repeat the reference travel cycle. For safety reasons it is only possible to close the door following a power failure in the press-and-hold mode (dead man's control).
4.2 General Information The operator control contains nine menus, from which the user can select numerous functions. All this requires is allowing the operator to learn and memorise the door’s travel path. Menu 1 (learning travel cycle) and menu 2 (operator lighting) are customer menus. Menus 3-9 are service menus and should only be altered if absolutely necessary. On first-time operation, the control system automatically switches to the learning menu. After com- pleting the learning travel cycle or after 60 sec., the sys- tem automatically switches to menu 0 (normal operation).
4.4.4 Resetting the control system (restoring the factory settings) In order to reset the control system, proceed as follows: 1. Withdraw mains plug 2. Press the PRG button and keep it pressed 3. Insert the mains plug 4. Release the PRG button, as soon as “C“ is displayed 5. Teaching the operator
4.3 Menu selection Menu selection is carried out using the PRG button. In doing so, pressing the button results in changing to the next menu. After arriving at menu 9, the system then changes back to menu 0.
5 Selecting the function
5.1 Customer menus: menu 2 (operator lighting) After the selection has been made, the menu number is displayed for one second, after which the corresponding menu parameter flashes up. This parameter can then be immediately activated or changed via the OPEN and CLOSE buttons.
4.4 Putting into operation
4.4.1 Customer menus: menu 1 (learning travel cycle) On first-time operation, the control system automatically switches to menu 1 (learning travel cycle). Here the ope- rator can be tuned to the door.
5.1.1 Setting the operator lighting (see figure 25) Select menu 2 by pressing the PRG button. The figure shown flashing indicates the setting of the afterglow phase for the operator lighting.
4.4.2 Teaching the operator In order to teach the operator to the door, a so called learning travel cycle must first be completed. During this learning travel cycle, the length of the travel path as well as the required force for opening and closing the door are learned and automatically stored. If the floor is uneven, it is possible to complete the lear- ning travel cycle without the mechanical limit stop. On completing the learning travel cycle, it is imperative that the mechanical limit stop be re-activated in order to guarantee the function of the mechanical door security kit.
Display Operator 0 Lighting OFF 1 60 sec. 2 90 sec. 3 120 sec. 4 150 sec. 5 * 180 sec. 6 210 sec.

7 240 sec. 8 270 sec. 9 300 sec.
Our photocells and closing edge safety devices incorpo- rate a self-testing unit.
Terminals 71 18 19 18 Display query self-testing query self-testing LS LS SKS SKS 0 * no 1 yes no no no 2 yes yes no no 3 no no yes no 4 yes no yes no 5 yes yes yes no 6 no no yes yes 7 yes no yes yes 8 yes
* = factory setting
Afterwards, switch to menu 0 by pressing the PRG button.
5.2 Service menus: menu 3 - menu 9 After the selection has been made, the menu number is displayed for one second, after which the correspon- ding menu parameter flashes up. To be able to alter this parameter, the PRG button must be pressed for 3 se- conds. As a result, the menu number is displayed once again. After the 3 seconds have elapsed, the parameter flashes up again. A new value can now be entered via the OPEN and CLOSE buttons. If the PRG button is released prematurely, the system switches to the next menu. If within 60 seconds in the tuned state no button is pressed, the system automa- tically returns to normal operation (menu 0).
Switch to menu 0 by pressing the PRG button.
5.2.3 Setting the function of the option relay (see figure 28) Select menu 5 by pressing the PRG button. The flashing figure displayed indicates the set function of the option relay, which can be altered using the OPEN or CLOSE buttons:
5.2.1 Setting the automatic closing timer (prerequisite is the fitting of a photocell and/or closing edge safety device), in addition in menu 4 a value unequal to zero must be selected) (see figure 26) Select menu 3 by pressing the PRG button. The flashing figure displayed indicates the door's set open phase in the OPEN position, which can be altered using the OPEN or CLOSE buttons:
Display Function 0 * Operator: no special function Relay: OFF Operator lighting: continuous light while the door is moving with programmed afterglow phase 1 Operator: 2 sec. warning phase Relay: slow-pulsing during the warning phase and while the door is moving. Operator lighting: flashing rapidly during the warning phase, continuous light while the door is moving with programmed afterglow phase 2 Operator: 2 sec. warning phase Relay: permanently switched on during the warning phase and while the door is moving Operator lighting: flashing rapidly during the warning phase, continuous light while the door is moving with programmed afterglow phase 3 Operator: no special function Relay: picks up with operator lighting Operator lighting: continuous light while the door is moving with programmed afterglow phase 4 as 1, but 5 sec. warning phase 5 as 2, but 5 sec. warning phase 6 Operator: no special function Relay: switched on permanently while the door is moving (e.g. to switch lightning relay with 100 % duty cycle) Operator lighting: continuous light while the door is moving with programmed afterglow phase
Display Waiting phase 0 * No automatic closing timer 1 10 sec. 2 20 sec. 3 30 sec. 4 45 sec. 5 60 sec. 6 90 sec. 7 120 sec. 8 150 sec. 9 180 sec.
When the automatic closing timer is active, the operator lighting flashes two seconds before the start of travel. If during this time the remote control is operated, the door's set waiting phase in the OPEN position starts afresh.
If during two successive travel cycles the door encounters an obstruction and reserves back to the OPEN travel limit, then the door stays in this end-of-travel position and an error message is issued.
Switch to menu 0 by pressing the PRG button.
5.2.2 Setting the photocell/closing edge safety device (see figure 27) Select menu 4 by pressing the PRG button. The flashing figure displayed indicates the following settings which can be altered using the OPEN or CLOSE button: LS = photocell SKS = closing edge safety device
For connection, see fig. 21. Switch to menu 0 by pressing the PRG button.

5.2.4 Force limit in the CLOSE direction (see figure 29) In menu 6 the automatic force limit for closing the door can be altered in the sensitive setting. This is only necessary for doors which run extremely unevenly. An unnecessarily high setting should not be selected. If the closing force is set too high, this can result in damage to property or injury to persons. In the case of extremely smooth-running doors, a lower setting can be selected if the sensitivity to obstructions is to be increased.
6 without automatic 7 without without 8 without short
Switch to menu 0 by pressing the PRG button.
Switch to menu 0 by pressing the PRG button.
6 Trouble-shooting (see page 54)
5.2.5 Door behaviour before/at the CLOSE travel limit (see figure 30) In menu 7 the automatic belt relief and the braking behaviour at the CLOSE travel limit can be influenced:
7 Terms and Conditions of the Warranty
Guarantee Period In addition to the statutory guarantee provided by the dealer, we provide the following guarantee of parts from the date of purchase:
Display “Soft“ stop Relief 0 long automatic 1 long without 2 long short 3 * short automatic 4 short without 5 short short 6 without automatic 7 without without 8 without short
a) 5 years on operator mechanics, motor and motor
controls b) 2 years on radio, impulse generators, accessories
There is no guarantee on consumables (e.g. fuses, batteries, lighting devices). Claims made under the guarantee do not extend the guarantee period. Following the supply of replacement parts the guarantee period is six months; or at least, the remainder of the guarantee period.
Switch to menu 0 by pressing the PRG button.
Conditions A claim under this guarantee is only valid for the country in which the equipment was bought. The product must have been purchased through authorised distribution channels. A claim under this guarantee exists only for damage to the product in the contract itself. Reimburse- ment of expenditure for dismantling and installation, testing of corresponding parts, as well as demands for lost profits and compensation for damages, are excluded from the guarantee. The receipt of purchase substan- tiates your right to claim under the guarantee.
5.2.6 Force limit in the OPEN travel direction (see figure 31) In menu 8 the automatic power limit for opening the door can be altered in the sensitive setting. This is only necessary for doors which run extremely unevenly. An unnecessarily high setting should not be selec- ted. If the opening force is set too high, this can result in damage to property or injury to persons. In the case of extremely smooth-running doors, a lower setting can be selected if the sensitivity to obstructions is to be increased.
Service rendered For the duration of the guarantee we will eliminate all product defects that are proven to be attributable to material or manufacturing faults. We pledge to provide free of charge and at our discretion to replace the de- fective parts with a non-defective one, to improve it, or to reimburse for a reduction in price.
Switch to menu 0 by pressing the PRG button.
5.2.7 Door behaviour before/at the OPEN travel limit (see figure 32) In menu 9 the automatic belt relief and the braking be- haviour at the “OPEN“ travel limit can be influenced.
Excluded are damages due to: - improper fitting and connection - improper commissioning or operating - external influences, such as fire, water, abnormal
Display “Soft“ stop Relief 0 * long automatic 1 long without 2 long short 3 short automatic 4 short without 5 short short
weather conditions - mechanical damage due to accidents, dropping, jolting - negligent or deliberate destruction - normal wear and tear or deficient maintenance
and special systems

- repair by non-qualified persons - use of non-original parts - removal or making unrecognisable the serial number
Airborne noise emission Garage door operator: ≤70 dB (A)
Replaced parts become our property.
Boom: Extremely flat (no more than 30 mm) with integral door secu- rity kit and maintenance-free, patented toothed belt with automatic belt tensioning.
Application: Exclusively for garages in the domestic sector. Not suitable for industrial / commercial use.
Automatic cut-out: Automatically programmed separately for both operational directions.
End-of-travel Self-learning, non-wearing, since cut-out/Force limit: no mechanical switches are used. Additionally integrated excess travel stop of approx. 45 s. Automatic cut-out read- justs itself during each travel cycle.
Connection: Connection technique without screws for external equipment with safe low voltage of 24 V DC, e.g. internal and external buttons for impulse control.
light ex factory - STOP/OFF switch can be
connected - Photocell or closing edge safety
device can be connected - Options relay for warning light,
Quick release: In the event of a power failure, actuated from the inside via a pull cord
Remote control: 2-button hand transmitter HS 2 and separate receiver.
8 Technical Data · additional external lighting

Display Fault/Error Possible cause Remedy
Learned force limit Required force for tuning Check door action too high process was ≥350 N Door movement extremely sluggish Disengage operator. It must be possible
to easily operate the door by hand
Entry not In menu 4 value equals zero In menu 3 it is only possible to set the possible automatic timer if the closing edge safety device (SKS) and photocell (LS) are activated in menu 4 beforehand.
Excess travel Belt torn Replace the belt stop
Operator defective Replace the operator
Overload current Internal error Retune the operator, if necessary replace
Force limit Door too sluggish Correct door movement
Obstruction in door area Remove obstruction; If necessary, retune the operator
Static current Terminal 12, 13 open Bridge terminal 12, 13 circuit
OFF-switch open Close OFF-switch
RPM Springs incorrectly Correct spring tension tensioned (caution!) Springs broken Have springs replaced by the garage door's service engineers
Photocell Light path interrupted Set the photocell Photocell defective Replace the photocell
Closing edge Photocell interrupted Check transmitter and receiver, safety device if necessary replace or completely replace the closing edge safety device
No reference Power failure Move door to OPEN travel limit point
Operator not Operator not yet set Set the operator limits yet set
Door is at the OPEN Door is at the inter- Door is at the CLOSED Impulse input (radio, end-of-travel postion mediate position (half end-of-travel postion button) acknowledged open)
6 Trouble-shooting