IT
Manuale d'uso ufficiale

Heider Pro5

184 pagine·3.7 MB·Radiocomunicazione·PDF·ENNLJA
Heider Pro5
Indice dei contenuti 65 sezioni DEUTSCH · FRANÇAIS · ESPAÑOL · ITALIANO · … MostraNascondi
DEUTSCHp.3FRANÇAISp.3ESPAÑOLp.3ITALIANOp.3TÜRKÇEp.3FREQUENCIES FREQUENCIESp.5GENERAL DEFINITION HEIDER PRO5 PMR 446p.6Electromagnetic Interaction / Compatibilityp.6WARNINGS / PRECAUTIONS HEIDER PRO5 PMR 446p.7REMOVING FROM THE PACKAGE AND CONTROLLING THE EQUIPMEN HEIDER PRO5 PMR 446p.8STANDARD ACCESSORIESp.8OPTIONAL ACCESSORIESp.8(USB)p.8(VGA)p.8INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446p.9WARNING!p.10KNOW THE DEVICE HEIDER PRO5 PMR 446p.11EXPLANATIONS OF THE CONTROL BUTTONS HEIDER PRO5 PMR 446p.12LCD SCREEN HEIDER PRO5 PMR 446p.13Ch-01 446.006 25p.13LOWp.13VOLp.13SYMBOL EXPLANATIONp.13MENU EXPLANATIONSp.14HEIDER PRO5 PMR 446p.14MENU ARTICLE EXPLANATION SETTINGSp.141 RXCODE OFF/CTCSS/DCSp.145 VOX OFF/1-9p.14MENU ADJUSTMENTSp.14RXCODE OFFp.14SOL 3p.14LIGHT ONp.15BEEP ONp.15VOX Op.15SAVE ONp.15TOT I805p.15SCANM TOp.15BCLO OFFp.15OPERATING HEIDER PRO5 PMR 446p.16SWITCHING ON / OFFp.16ADJUSTING VOICE LEVELp.16ADVANCED OPERATION HEIDER PRO5 PMR 446p.17Adjust the incoming signal in accordance with the instructions given below:p.17The procedure to adjust lighting mode is as follows:p.19BEEP (Keypad Sound ON/OFF)p.19VOX (Voice Operated Exchange)p.20Warning:p.20SAVE (Battery Saving)p.21TOT (Time-Out Timer)p.22SCANM (Scan Mode)p.22ADDITIONAL FUNCTIONS AND SETTINGS HEIDER PRO5 PMR 446p.24ADDITIONAL FUNCTIONS AND SETTINGSp.25FM RADIO SCANp.25TROUBLESHOOTING MANUALp.25PROBLEMS SOLUTIONSp.25TECHNICAL SPECIFICATIONS HEIDER PRO5 PMR 446p.26Radio and Telecommunication Terminal Equipmentp.271999/5/EC (T & TTE) Regulationp.27DECLARATION DECLARATION OF CONFORMITYp.27MARKET SURVELLIENCEp.28WARRANTY WARRANTY CERTIFICATEp.28TERMS OF TERMS OF WARRANTYp.29ATTENTIONp.30PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODESp.31WELLENCODE WELLENCODEp.35
Page 1 of the Heider Pro5 user manual
Pagina 1 · clicca per ingrandire
Pagina 1
Heider Pro5 diagram (page 1)
Fig. 1
Page 2 of the Heider Pro5 user manual
Pagina 2 · clicca per ingrandire
Pagina 2
Page 2 of the Heider Pro5 user manual
Page 3 of the Heider Pro5 user manual — DEUTSCH
Pagina 3 · clicca per ingrandire
Pagina 3
Heider Pro5 — DEUTSCH diagram (page 3)
Fig. 2

DEUTSCH

FRANÇAIS

ESPAÑOL

ITALIANO

TÜRKÇE

121-149 · 151-179

Page 4 of the Heider Pro5 user manual — DEUTSCH
Pagina 4 · clicca per ingrandire
Pagina 4
Page 4 of the Heider Pro5 user manual — DEUTSCH
Page 5 of the Heider Pro5 user manual — FREQUENCIES FREQUENCIES
Pagina 5 · clicca per ingrandire
Pagina 5
Heider Pro5 — FREQUENCIES FREQUENCIES diagram (page 5)
Fig. 3

FREQUENCIES FREQUENCIES

0CTCSS Off20131.8 167.021136.5 271.922141.3 374.423146.2 477.024151.4 579.725156.7 682.526162.2 785.427167.9 888.528173.8 991.529179.9 1094.830186.2 1197.431192.8 12100.032203.5 13103.533210.7 14107.234218.1 15110.935225.7 16114.836233.6 17118.837241.8 18123.038250.3 19127.3--
Page 6 of the Heider Pro5 user manual — Electromagnetic Interaction / Compatibility
Pagina 6 · clicca per ingrandire
Pagina 6
Heider Pro5 — GENERAL DEFINITION HEIDER PRO5 PMR 446 diagram (page 6)
Fig. 4

GENERAL DEFINITION HEIDER PRO5 PMR 446

T

Heider Pro5 — GENERAL DEFINITION HEIDER PRO5 PMR 446 diagram (page 6)
Fig. 5

hank you for your trust in Heider PRO5. Please read User’s Manual carefully to obtain information on various features of our radio.

This device is a non-licensed FM radio which ensures two-way amateur radio communication in local area with its unique monitoring capacity in the class PMR446.

Electromagnetic Interaction / Compatibility

This product generates RF power which may result in interaction with other de vices or systems during communication. In order to avoid such an interaction, turn the radio off in the areas where the interaction is not allowed. DO NOT OPE RATE the radio in areas sensitive to ele ctromagnetic radiation such as hospitals, planes and other areas which have possi bility of explosion.

Page 7 of the Heider Pro5 user manual — WARNINGS / PRECAUTIONS HEIDER PRO5 PMR 446
Pagina 7 · clicca per ingrandire
Pagina 7
Heider Pro5 — WARNINGS / PRECAUTIONS HEIDER PRO5 PMR 446 diagram (page 7)
Fig. 6

WARNINGS / PRECAUTIONS HEIDER PRO5 PMR 446

  • Do not have your device repaired by anyone else than authorized service technicians.
  • Do not let the radio expose to direct sunlight for too long.
  • Do not put the radio on a nonstable surface.
  • Protect the radio against dust and bad weather conditions.
  • Do use the radio or charge the battery in areas where there is a risk of explosion.

SAFETY It is important for user to be aware of the risks emerging from operating the radio.

  • WARNING Please switch your radio off in the places given below:
  • Areas where explosions may occur (inflammable gas, dust particles, metallic dusts, grain dusts, etc.),
  • Gas stations,
  • Places where medical supplies are kept, etc.
Page 8 of the Heider Pro5 user manual — (USB)
Pagina 8 · clicca per ingrandire
Pagina 8
Heider Pro5 — REMOVING FROM THE PACKAGE AND CONTROLLING THE EQUIPMEN HEIDER PRO5 PMR 446 diagram (page 8)
Fig. 7

REMOVING FROM THE PACKAGE AND CONTROLLING THE EQUIPMEN HEIDER PRO5 PMR 446

Remove the radio from its box carefully. You should check the parts mentioned below. Contact us if there is a missing or damaged part.

STANDARD ACCESSORIES

PARTITEM Adaptor1 Li-ion Battery1 Earphones1 Belt Clip1 Hand Strap1 User’s Manual1
Heider Pro5 — STANDARD ACCESSORIES diagram (page 8)
Fig. 8

Adaptor Li-ion Battery Earphones Belt Clip Hand Strap

OPTIONAL ACCESSORIES

Heider Pro5 — OPTIONAL ACCESSORIES diagram (page 8)
Fig. 9

(USB)

(VGA)

Show 7 more labels / short text on this page
Cigarette lighter adapter · Charging · Microphone, · Data cable · Data cable · station · earphone
Page 9 of the Heider Pro5 user manual — INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446
Pagina 9 · clicca per ingrandire
Pagina 9
Heider Pro5 — INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446 diagram (page 9)
Fig. 10

INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446

INSERTING THE BELT CLIP If there is a need to use the belt clip, attach it behind the battery shown in image 1.

Heider Pro5 — INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446 diagram (page 9)
Fig. 11

INSERTING THE EARPHONES AND THE MICROPHONE Insert the inputs of the earphones and the microphone to the SP. &MIC. Socket shown in image 2.

INSERTING THE BATTERY Operating the radio repatedly over time will absolutely lower the performance of the lithium ion batteries chargeable up to 400 times with high performance capacity expires. If you are using an old battery, it is recommended to replace it with a new one.

Heider Pro5 — INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446 diagram (page 9)
Fig. 12

The battery can be inserted easily. 1. After adjusting the battery cover to the position of “unlock”, slide down the battery cover downwards to remove it. 2. Place the battery in the battery slot. 3. Insert back the battery cover in its place and slide the latch to the position of “lock”.

Show 4 more labels / short text on this page
Image 1 · Image 2 · Lock · Unlock
Page 10 of the Heider Pro5 user manual — WARNING!
Pagina 10 · clicca per ingrandire
Pagina 10

INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446

Heider Pro5 — INSERTING THE ACCESSORIES HEIDER PRO5 PMR 446 diagram (page 10)
Fig. 13

CHARGING THE BATTERY If the battery has not been used before or the bat tery is down, the battery can be charged by con necting to the EXT DC socket of the charging de vice as shown in the image. If DC power of 12~16 volts is available, optional DC adaptor can be used by inserting into the lighter input to charge the battery. The charging level will be shown on the screen while the battery is being charged and TX/ BUSY indicator will glow in red color (see image 4). When the charging is completed, TX indicator will glow in green color.

WARNING!

  • Use the charging device only to charge the radio battery.
  • The charging device may cause sounds in the TV and radio signals. Therefore, do not charge the battery near such devices.
  • Charge the battery in places with the temperature of 41°F - 95°F (+5°C - +35°C). The places excluding the range of this temperature may cause damage on the battery.
  • If the battery is not charged within a few hours, there is a problem with it. In case of such situations, do not continue charging the battery and contact us.
  • Remove the battery if you will not use it for a long time. Otherwise, the battery can leak down and your radio can be damaged.
  • The battery will be run out of when not used for a long time and it should be charged up to half once in every six months.

Image 4

Page 11 of the Heider Pro5 user manual — KNOW THE DEVICE HEIDER PRO5 PMR 446
Pagina 11 · clicca per ingrandire
Pagina 11
Heider Pro5 — KNOW THE DEVICE HEIDER PRO5 PMR 446 diagram (page 11)
Fig. 14

KNOW THE DEVICE HEIDER PRO5 PMR 446

Heider Pro5 — KNOW THE DEVICE HEIDER PRO5 PMR 446 diagram (page 11)
Fig. 15
Page 12 of the Heider Pro5 user manual — EXPLANATIONS OF THE CONTROL BUTTONS HEIDER PRO5 PMR 446
Pagina 12 · clicca per ingrandire
Pagina 12
Heider Pro5 — EXPLANATIONS OF THE CONTROL BUTTONS HEIDER PRO5 PMR 446 diagram (page 12)
Fig. 16

EXPLANATIONS OF THE CONTROL BUTTONS HEIDER PRO5 PMR 446

[CALL]Main CALL button is used for adjusting the frequency of operation, voice level, menu choices and other settings. In order to switch this CALL button on, pull the button to unlock the mechanical call lock and then push the CALL button. [PTT]Push this button to send and receive signals, thus the transmission will be realized. [VOL]Hold down the VOL button to deactivate the voice blocking feature. This procedure ensures that you hear very weak signals close to the background sound level. In order to make the adjustments, push VOL button and push CALL button. [ON/OFF]In order to switch the radio on or off, hold down the SWITCH ON-OFF button for two seconds. [F/ALERT]In order to activate alternative button function in settings such as scan and memory writing mode, push the button. Hold down the button to activate the alarm function. [MENU]Push MENU button to enter the MENU. You will see difef rent function settings under the MENU section when you push CALL button. Hold down the button to activate or deactivate the key lock. Warning! [F/ ALERT], [UV], [LIGHT/FM] functions will be invalid when the key lock is activated. [LIGHT/FM]Hold down the light button to activate the torchlight feature. Hold down the FM button to use FM radio feature. F+[MENU]Push [F/ALERT] button and then [MENU] button to activate Scanning Function. [VOL]+[CALL]Push [VOL] button and then switch on [CALL] button to adjust voice level.
Page 13 of the Heider Pro5 user manual — F
Pagina 13 · clicca per ingrandire
Pagina 13
Heider Pro5 — LCD SCREEN HEIDER PRO5 PMR 446 diagram (page 13)
Fig. 17

LCD SCREEN HEIDER PRO5 PMR 446

The screen icons are shown during certain procedures or while certain features are active. Knowing the meaning of the indicators and how to adjust radio functions will help you to operate the radio easily.

F

Ch-01 446.006 25

LOW

VOL

SYMBOL EXPLANATION

Push Secondary Key Pad Active ([F/ALERT] button

Show 9 more labels / short text on this page
CTCSS Procedure · DCS Procedure · FM Radio (65-108MHz) · Low/High Output Power · VOX Function Activated · Key Lock Activated · Keypad Sound On · Battery Indicator · Sound Level
Page 14 of the Heider Pro5 user manual — SOL 3
Pagina 14 · clicca per ingrandire
Pagina 14
Heider Pro5 — MENU EXPLANATIONS diagram (page 14)
Fig. 18

MENU EXPLANATIONS

HEIDER PRO5 PMR 446

MENU ARTICLE EXPLANATION SETTINGS

1 RXCODE OFF/CTCSS/DCS

2 SQL (Squelch) 0-9

3 LIGHT (LCD Lighting) OFF/ON/Key

4 SOUND (Keypad Sound) OFF/ON

5 VOX OFF/1-9

6 SAVE (Battery Saving) ON/OFF

7 TOT (Time-Out Timer) OFF/30/60/90/120/150/180S

8 SCANM (Scan Mode) TO/CO

9 BCLO (Busy Channel Lock-Out) ON/OFF

Heider Pro5 — 5 VOX OFF/1-9 diagram (page 14)
Fig. 19

MENU ADJUSTMENTS

HEIDER PRO5 PMR 446

RXCODE OFF

Push [MENU] button, switch to MENU [01] RXCODE.

SOL 3

Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [02] SQL.

Page 15 of the Heider Pro5 user manual — Warning!
Pagina 15 · clicca per ingrandire
Pagina 15

LIGHT ON

Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [03] LIGHT.

BEEP ON

Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [04] BEEP.

VOX O

Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [05] VOX.

SAVE ON

Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [06] SAVE.

TOT I805

[Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [07] TOT.

SCANM TO

[Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [08] SCANM.

BCLO OFF

Push [MENU] button, rotate [CALL] button clockwise or counter clockwise, switch to MENU [09] BCLO.

Warning!

  • Confirm the settings after pushing [UV] button and exit.
Page 16 of the Heider Pro5 user manual — ADJUSTING VOICE LEVEL
Pagina 16 · clicca per ingrandire
Pagina 16
Heider Pro5 — OPERATING HEIDER PRO5 PMR 446 diagram (page 16)
Fig. 20

OPERATING HEIDER PRO5 PMR 446

SWITCHING ON / OFF

1. Make sure that the battery is inserted and full. Insert the antenna to the ANTENNA socket in the upper top panel.
2. Push [ON/OFF] button and DC voltage will be displayed on LCD for 2 seconds and beeping voice will be heard. Later on, normal indicator of the operational function will appear on the screen.
3. Hold down [ON/OFF] button for one second again to switch the radio off.

ADJUSTING VOICE LEVEL

Push [CALL] button to unlock mechanical call lock. Push [CALL] button after pushing [VOL] button to adjust the voice level you want. The voice level will increase when you rotate VOL button clockwise.

Page 17 of the Heider Pro5 user manual — Adjust the incoming signal in accordance with the instructions given below:
Pagina 17 · clicca per ingrandire
Pagina 17
Heider Pro5 — ADVANCED OPERATION HEIDER PRO5 PMR 446 diagram (page 17)
Fig. 21

ADVANCED OPERATION HEIDER PRO5 PMR 446

RXCODE In certain situations, you can want to hear the calls only from certain persons or groups. In such situations you can ignore unwanted incoming calls from other persons using the same frequency by using selective call.

Adjust the incoming signal in accordance with the instructions given below:

1. Push [MENU] button, switch on [CALL] button and switch to MENU [01] RXCODE.
2. Later on push [U/V] button and enter the setting mode.
3. Make your choice on OFF / 67.0-754N by rotating [CALL] button clockwise or counter clockwise, push [MENU] button again and select the code (positive or negative). For example 023N---023I (OFF -67.0-023N-023I).
4. Push [U/V] button to save the settings and EXIT. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.
Page 18 of the Heider Pro5 user manual — ADVANCED OPERATION HEIDER PRO5 PMR 446
Pagina 18 · clicca per ingrandire
Pagina 18

ADVANCED OPERATION HEIDER PRO5 PMR 446

SQL (Squelch) Squelch System allows you to turn down the background noise while there is no incoming signal. Squelch systems renders operation mode on ‘Stand-by’ more efficient and reduces the current consumption of the battery significantly. Adjust the level of squelch in accordance with the instructions given below:

1. Push [MENU] button, rotate[CALL] button. Switch to MENU [03] SQL. 2. Then push [U/V] button and switch to SQL5 level from the default settings. 3. Adjust among 0/1/2/3/4/5/6/7/8/9 by rotating [CALL] button clockwise or counter clockwise. (Default push down level) 4. Select the level at which the background noise disappears while there is no signal. Push [U/V] button to save the settings. 5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.

LIGHT (LCD Lighting ON/Button/OFF) Heider PRO5 has a red lighting on its monitor for a comfortable use at nights. Red lighting reduces the distortions at night visions to a level of minimum while ensuring that your screen is clearly visible in the dark. There are 3 options to activate night light:

Key : Enlightens the LCD when any button is pushed. ON : Enlightens LCD continuously. OFF : Deactivates LCD light.

Page 19 of the Heider Pro5 user manual — BEEP (Keypad Sound ON/OFF)
Pagina 19 · clicca per ingrandire
Pagina 19

ADVANCED OPERATION HEIDER PRO5 PMR 446

The procedure to adjust lighting mode is as follows:

1. Push [MENU] button, rotate [CALL] button, switch to MENU [04] LIGHT. 2. Push [U/V] button to enter adjustment mode. 3. Make the ON/OFF and Key adjustments by rotating [CALL] button clockwise or counter clockwise. 4. Push [U/V] button to save the settings. 5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.

BEEP (Keypad Sound ON/OFF)

If the Keypad Sound is disturbing you (particularly when operating the radio in a silent room), you can deactivate Keypad Sounds in accordance with the instructions given below:

1. Push [MENU] button, rotate [CALL] button, switch to MENU [05] BEEP.
2. Then, push [U/V] button to enter adjustment mode.
3. Adjust one ON/OFF settings by rotating [CALL] button clockwise or counter clockwise.
4. Push [U/V] button to save the settings.
5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode. ON-Key sounds are activated, the icon is shown on the LCD. OFF-Key sounds are deactivated.
Page 20 of the Heider Pro5 user manual — Warning:
Pagina 20 · clicca per ingrandire
Pagina 20

ADVANCED OPERATION HEIDER PRO5 PMR 446

VOX (Voice Operated Exchange)

VOX, resolves the requirement to change the transmission mode manually each time you want to send a message. The radio automatically switches to transmission mode when VOX switch system senses that you start to speak to the microphone. Please follow the instructions given below:

1. Push [MENU] button, rotate [CALL] button, switch to MENU [06] VOX.
2. Then, push [U/V] button to enter adjustment mode.
3. Adjust OFF/1/2/3/4/5/6/7/8/9 setting by rotating [CALL] button clockwise or counter clockwise.
4. Push [U/V] button to save the setting.
5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.

Warning:

Degrees 7-9: Most Sensitive VOX Level Setting under silent circumstances Degrees 4-6: VOX Level Setting in Medium Sensitivity under normal circumstances Degrees 1-3: Least Sensitive VOX Level Setting under very noisy circumstances While VOX function is activated, ‘VOX’ icon can be seen on the LCD.

Page 21 of the Heider Pro5 user manual — SAVE (Battery Saving)
Pagina 21 · clicca per ingrandire
Pagina 21

ADVANCED OPERATION HEIDER PRO5 PMR 446

SAVE (Battery Saving)

Heider PRO5 has battery saving feature for a long term transmission. In case the incoming signal is strong, power output is automatically adjusted to reduce it with this feature. For instance, there is no need to strong power output to access silencing in close distances to repetitive station. Automatically activating the battery saving and low power operation option you have selected ensures that undesirable situations such as battery leakage are avoided for an efficient communication. In order to activate battery saving:

1. Push [MENU] button, rotate [CALL] button, switch to MENU [14] SAVE.
2. Adjust the settings after pushing [U/V] button.
3. Adjust SAVE: ON/OFF settings by rotating [CALL] button clockwise or counterclockwise.
4. Push [U/V] button to save the settings adjusted. 5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.
Page 22 of the Heider Pro5 user manual — SCANM (Scan Mode)
Pagina 22 · clicca per ingrandire
Pagina 22

ADVANCED OPERATION HEIDER PRO5 PMR 446

TOT (Time-Out Timer)

TOT feature allows adjusting the duration of communication to a previously programmed value with a safety button and saving the battery by limiting the duration of communication. Default setting is 180 seconds and you can adjust the timer in line with the instructions given below:

1. Push [MENU] button, rotate [CALL] button, switch to MENU [15] TOT.
2. Enter adjustment mode after pushing [U/V] button.
3. Adjust TOT: OFF/30S/60S/90S/120S/150S/180S setting by rotating [CALL] button clockwise or countercloskwise.
4. Push [U/V] button to save the setting. 5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.

SCANM (Scan Mode)

Heider PRO5 allows you to scan memory channels, operation bands or a section of these bands. The radio automatically pauses on the encountered signals and allows communicatioın with the requested station. Follow the instructions given below to activate scan mode:

Page 23 of the Heider Pro5 user manual — ADVANCED OPERATION HEIDER PRO5 PMR 446
Pagina 23 · clicca per ingrandire
Pagina 23

ADVANCED OPERATION HEIDER PRO5 PMR 446

1. Push [MENU] button, rotate [CALL] button, switch to MENU [16] SCANM. 2. Enter adjustment mode after pressing [U/V] button. 3. Adjust SCANM: TO/CO setting by rotating [CALL] button clockwise or countercloskwise.
4. Push [U/V] button to save the setting. 5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.

BCLO (Busy Channel Lock-Out) BCLO prevents radio transmitter from being activated when there is a signal strong enough to preclude squelch feature. BCLO prevents your messages from being distorted on a frequench where stations which use different CTCSS or DCS codes are active (in such situations, the radio may have automatically switched its own tone decoder to silent mode). The default setting for BCLO is OFF and please follow the instructions below to activate it:

1. Push [MENU] button, rotate [CALL] button, switch to MENU [18] BCLO. 2. Push A [U/V] button and enter adjustment mode. 3. Adjust BCLO: ON/ OFF setting by rotating [CALL] button clockwise or counter closkwise.
4. Push [U/V] button to save the setting. 5. Push [MENU] or [PTT] buttons to EXIT to normal operation mode.
Page 24 of the Heider Pro5 user manual — ADDITIONAL FUNCTIONS AND SETTINGS HEIDER PRO5 PMR 446
Pagina 24 · clicca per ingrandire
Pagina 24
Heider Pro5 — ADDITIONAL FUNCTIONS AND SETTINGS HEIDER PRO5 PMR 446 diagram (page 24)
Fig. 22

ADDITIONAL FUNCTIONS AND SETTINGS HEIDER PRO5 PMR 446

EMERGENCY ALARM FEATURE 1. Hold down [F/ALERT] button for approximately 1-2 seconds. 2. Adjust the setting to emergency alarm mode. And the emergency alarm will be heard. 3. Push [PPT] button to exit to normal operation mode.

FM RADIO FUNCTION 1. Push [L/R] button on the side for 2 seconds and select FM radio mode. 2. Adjust the frequency by rotating [CALL] button. (FM Broadcasting coverage is between 87.0mHz and108.0mHz while the base frequency is 100kHz) . 3. Push [L/R] button and hold it down, exit from FM radio mode. 4. Hold down button to change FM radio frequency mode and FM radio channel saving mode.

Follow the instructions given below to change the broadcasting frequencies:

Broadcast at VFO-Mode: 1. Hold down [U/V] button for 3 seconds. 2. Select memory. 3. Push [U/V] button again until you hear the “beep” sound.

4. Adjust the frequency you want to save on FM radio frequency mode. 5. Push [F/ALERT] button and then push [U/V] button. You will see 01-15 flashing on an off on the LCD, rotate [CALL] button to save. 6. Push [U/V] button to confirm saving.

The communication between radios ranks in priority on FM Radio Mode, which means that the radio will automatically exit FM radio mode when there is an incoming signal.

Page 25 of the Heider Pro5 user manual — HEIDER PRO5 PMR 446
Pagina 25 · clicca per ingrandire
Pagina 25

ADDITIONAL FUNCTIONS AND SETTINGS

HEIDER PRO5 PMR 446

FM RADIO SCAN

Push [F/ALERT]button to scan the entire band on FM Radio mode and then push [MENU]button. Rotate [CALL] button clockwise or counter clockwise to scan the band from low to high or from high to low. The scan will stop on the requested channel when a certain channel is scanned for. Rotate [CALL] button to continuously scan from low to high or from high to low. Push any button to exit scan mode.

Heider Pro5 — HEIDER PRO5 PMR 446 diagram (page 25)
Fig. 23

TROUBLESHOOTING MANUAL

HEIDER PRO5 PMR 446

PROBLEMS SOLUTIONS

The radio does not switch on. Check the placement of the battery and/or replace the batteries.

Voltage capacity is down

immediately. Battery life is over, replace with a new one.

I cannot communicate with other

Make sure that the frequency that you use and your CTCSS is the same as yout group members are using.

group members.

I hear the voices of other groups. Change your CTCSS for channel. Besides, use CTSS for all of the radios in your group.

Page 26 of the Heider Pro5 user manual — TECHNICAL SPECIFICATIONS HEIDER PRO5 PMR 446
Pagina 26 · clicca per ingrandire
Pagina 26
Heider Pro5 — TECHNICAL SPECIFICATIONS HEIDER PRO5 PMR 446 diagram (page 26)
Fig. 24

TECHNICAL SPECIFICATIONS HEIDER PRO5 PMR 446

Frequency Range PMR446 (446.00625MHz-446.09375MHz)

Channel Capacity 8 Channels

Operation Voltage 3.7V

Battery Life (5-5-90 operation cycle) 8-12 hours

Frequency Stability 2.5 ppm (-20°C - +60°C)

Operation Temperature -30°C - +60°C

Antenna Impedence 50 Ω

Size 47mm x 81mm x 23mm

Weight Approximately 130g (without battery)

RF Power Output 0.5W

Transmission Current ≤ 1.4A

Sensitivity (12dB SINAD) 0.2uV

Image Rejection ≥ 60dB

Sound Output Power 500Mw

Receiver Current ≤ 400mA

Stand-by Current ≤ 75mA

Standard Battery 1500mAh · Modulation F3E · FM Sound 45dB(W)/42dB(N)

Page 27 of the Heider Pro5 user manual — DECLARATION DECLARATION OF CONFORMITY
Pagina 27 · clicca per ingrandire
Pagina 27

Radio and Telecommunication Terminal Equipment

1999/5/EC (T & TTE) Regulation

Company: Metem Teknoloji Sistemleri San. Ve Tic. Ltd. Sti. Kemankes Mah. Gumus Halka Sok. Bozburun Is Hanı No:4 Kat:2 Karakoy / Beyoglu / ISTANBUL / TURKEY

DECLARATION DECLARATION OF CONFORMITY

All of the responsibilities of the product titled as PMR446 PRO5 were undertaken and all of the required terms were fulfilled in scope of 1999/e/EC Regulation and its conformity with the below-mentioned standards are accepted and declared by us:

Medical: EN 60950-1:2006+A11:2009 EMC: EN 301 489-1 V1.9.2 EN 301 489-5 V 1.3.1 Radio: EN 300 296-1 V 1.3.1 EN 300 296-2 V 1.3.1

The criteria for the conformity of assessment methods were taken into consideration pursuant to Additional article 4 of Regulation T&TTE 1999/5/EC

Mentioned product is CE licensed.

Date and place of issue30 March 2012, Turkey
SignatureYusuf Kırtorun General Manager
Heider Pro5 — DECLARATION DECLARATION OF CONFORMITY diagram (page 27)
Fig. 25
Page 28 of the Heider Pro5 user manual — WARRANTY WARRANTY CERTIFICATE
Pagina 28 · clicca per ingrandire
Pagina 28

REPUBLIC OF TURKEY MINISTRY OF CUSTOMS AND TRADE DIRECTORATE GENERAL FOR CONSUMER PROTECTION AND

MARKET SURVELLIENCE

Date of issue and number of certificate : 20.07.2012-114863 Certificate expiration date : 20.07.2014 The use of this certificate has been allowed by Republic of Turkey Directorate General for Consumer Protection and Market Surveillance pursuant to Law on Consumer Protection No. 4077 and the Regulation on Certificate of Warranty Implementation Principles entering into force based on this Law. Manufacturer and Importer Company’s Title : METEM TEKNOLOJI SISTEMLERI SAN. VE TIC. LTD. STI. Address : Kemankes Mah. Mumhane Cad. Gumus Halka Sk. No:4 Kat:2 Karakoy / Istanbul / TURKEY Phone : +90 212 292 24 24 Fax : +90 212 292 24 48 Product Type : RADIO DEVICES Brand : Heider Model : Pro5 Banderol and Serial Number : Date and Place of Delivery : Warranty Period : 2 Years Minimum Period of Repair : 20 work days Distributor Company’s Title : Address : Phone : Fax : Invoice Date and Number :

WARRANTY WARRANTY CERTIFICATE

Salim ÖKSÜZOĞLU On Behalf of the Minister HEAD OF DEPARTMENT The document can be validated on the address www.tuketici.gov.tr

Page 29 of the Heider Pro5 user manual — TERMS OF TERMS OF WARRANTY
Pagina 29 · clicca per ingrandire
Pagina 29
1. The warranty period begins as of the date of delivery of the product and is 2 (two) years.
2. The entire product including all of its components is covered by the warranty of our Company.

3. In the event of a product failure within the period of warranty, the duration of time spent for repair is added to the duration of warranty. This duration starts with the date of notification of the malfunction to the service station and in the event that the service station is not available, to the seller, dealer, agency, representative, exporter or importer/ manufacturer. In case the malfunction of the product is not resolved within 15 days, importer/manufacturer of exporter has to allocate another product with similar features to the use of the consumer.

TERMS OF TERMS OF WARRANTY

4. In the event of a product failure due to material and craftsmanship as well as faulty assemblage, the product will be repaired without requiring any craftsmanship expense, replaced component compensation or any other fee.

5. If the customer claimed the right to repair yet the product; Repeats the same failure more than two times or different failures occur more than four times within a year provided that it is within the warranty period or different failures are more than six times in total within the determined warranty period, and these failures continuously disable utilizing the product, The maximum duration required for repair is exceeded, There is no available service station of the company; the consumer can demand replacement of the product free of charge, reimbursement of the product or discount in the price in proportion with the fault when it is determined that the failure is not possible to be repaired by means of a report to be prepared by the seller, dealer, agency, representative, exporter or importer/ manufacturer respectively.

6. Failures to occur due to the use of the product against the issues included in the user’s manual of the product are not covered by the warranty.
7. Directorate General for Protection of Consumer and Competition, Ministry of Industry and Trade can be applied for the possible problems to be encountered in regard to the Certificate of Warranty.
Page 30 of the Heider Pro5 user manual — TERMS OF TERMS OF WARRANTY
Pagina 30 · clicca per ingrandire
Pagina 30

ATTENTION

You need to submit your Certificate of Warranty and Invoice for all of your applications.

Please keep your certificates.

Do not open your device in no circumstances, do not operate it with any other accessories than those

TERMS OF TERMS OF WARRANTY

given to you or do not try to repair it by yourself. Otherwise, the warranty of your device will be void.

Pay attention not to damage the device by impact, high temperature or excessive dust.

The problems to occur as a result of these reasons are not covered by the warranty.

The warranty of your device will be void if your device is opened by unauthorized people.

No reimbursement or free service is rendered for devices with void warranty.

Our clients who purchase the device are deemed to accept these terms.

IMPORTER - EXPORTER COMPANY METEM TEKNOLOJI SISTEMLERI SAN. VE TIC. LTD. STI. Kemankes Mah. Mumhane Cad. Gumus Halka Sk. No:4 Kat:2 Karakoy / Istanbul / TURKEY Tel: +90 212 292 24 24

AUTHORIZED SERVICE STATION TS 13193 Authorized Services – for radio devices - rules ILERI ELEKTRONIK – YARCAN FEYZİOĞLU Gazipasa Mah. Tekke Cami Sok. No: 25 TRABZON Tel: +90 462 321 06 64

The warranty period of your device starts as of the date of delivery and is 2 (two) years. The expected life of your device is 10 (ten) years.

Page 31 of the Heider Pro5 user manual — PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODES
Pagina 31 · clicca per ingrandire
Pagina 31
Heider Pro5 — PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODES diagram (page 31)
Fig. 26

PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODES

Page 32 of the Heider Pro5 user manual — PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODES
Pagina 32 · clicca per ingrandire
Pagina 32

w w w . m e t e m t e k n o l o j i . c o m

w w w . m e t e m . e u

Page 33 of the Heider Pro5 user manual — FRANÇAIS
Pagina 33 · clicca per ingrandire
Pagina 33

DEUTSCH

FRANÇAIS

ESPAÑOL

ITALIANO

TÜRKÇE

121-149 · 151-179

Page 34 of the Heider Pro5 user manual — PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODES
Pagina 34 · clicca per ingrandire
Pagina 34
Page 34 of the Heider Pro5 user manual — PMR 446 RADIO DCS CHANNEL, NUMBER AND FREQUENCY CODES
Page 35 of the Heider Pro5 user manual — WELLENCODE WELLENCODE
Pagina 35 · clicca per ingrandire
Pagina 35
Heider Pro5 — WELLENCODE WELLENCODE diagram (page 35)
Fig. 27

WELLENCODE WELLENCODE

Riparazione

Risoluzione dei problemi

Problemi comuni, cause probabili e soluzioni.

ProblemaPossibile causaSoluzione
The radio does not switch on.Check the placement of the battery and/or replace the batteries. p.25
Voltage capacity is down immediately.Battery life is over, replace with a new one. p.25
I cannot communicate with other group members.Make sure that the frequency that you use and your CTCSS is the same as yout group members are using. p.25
I hear the voices of other groups.Change your CTCSS for channel. Besides, use CTSS for all of the radios in your group. p.25

Fai una domanda su Heider Pro5

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Heider Pro5

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Heider Pro5 manuale in PDF

184 pagine·3.7 MB·Radiocomunicazione·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…