Business Projectors

Introduction to ESC/VP21- 3
ESC/VP21 Command Formats -4
Projector state and commands -5
Command transmission timing -6
Command list and Applicable Models -7
Command Details -9
Appendix -17
Revision History -18
Copyright Notice: All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SEIKO EPSON CORPORATION. No patent liability is assumed with respect to the use of the information contained herein. Neither is any liability assumed for damages resulting from the use of the information contained herein.
Neither SEIKO EPSON CORPORATION nor its affiliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or (excluding the U.S.) failure to strictly comply with SEIKO EPSON CORPORATION’s operating and maintenance instructions.
SEIKO EPSON CORPORATION shall not be liable against any damages or problems arising from the use of any options or any consumable products other than those designated as Original EPSON Products or EPSON Approved Products by SEIKO EPSON CORPORATION.
EPSON is a registered trademark of SEIKO EPSON CORPORATION. EasyMP is a trademark of SEIKO EPSON CORPORATION. Macin- tosh, Mac, and iMac are registered trademarks of Apple Computer, Inc. IBM is a registered trademark of International Business Machines Corporation. Windows and Windows NT are registered trademarks of Microsoft Corporation in the United States of America.
General Notice: Other product names used herein are also for identification purposes only and may be trademarks of their respective owners. EPSON disclaims any and all rights in those marks.
©SEIKO EPSON CORPORATION 2003-2005. All rights reserved.

ESC/VP21 is a control command and protocol for Epson projectors, which is used for A/V controller to control and monitor Epson projectors. The command codes are comprised of ASCII codes. Therefore the command codes can be understood very easily and you can easily control projectors using a PC with a terminal emulator such as Microsoft Hyper terminal. Since ESC/VP21 is independent of communication protocols,Serial, USB or TCP/IP network can be used to transmit the commands to projec- tors.


DVD
Projector with USB I/F

PC

A/V controller with network I/F
Controller Projector · Video camera

2.1.Set command format
A set command consists of a command and a parameter. Projector returns a colon after executing the command. There are two types of parameters. One is fixed such as ON, OFF, or 21.Other is a step parameter such as INC, DEC or INIT.
INC increments the parameter by one. DEC decrements the parameter by one. INIT initializes the parameter.
Set command example 1
Colon from projector Command Space Parameter Return
Set command example 2
Colon from projector Command Space Parameter Return
A get command consists of a command and ?. Projector returns a response parameter after executing the command.
Colon from projector Command ? Return
Colon from projector Command = Parameter
The null command is a command code of the return key code (Hex 0D). Projector returns a colon. The null command can be used to confirm that the projector is in operation.
Projector returns “ERR” and a return key code (Hex 0D) and a colon when it receives invalid commands. ERR :
Get command example

3.1.Standby state (operation indicator is in orange)
When a projector is in a standby state, executable commands depend on projector models and standby configuration (network on, network off). Refer to the following table.
(note1) EMP-61/81/830/835/740/745/821/828 returns "ERR" when it received commands other than PWR ON, PWR? , LAMP? and NULL commands. (note2) EMP-7800/7850 returns "ERR" when it received commands other than PWR ON, PWR? , SOURCE? and NULL commands. (note3) EMP-8300/9300 returns "ERR" when it received commands other than PWR ON, SOURCE xx, PWR? , SOURCE? And NULL commands.
All projectors returns "ERR" when the command format is not good. All projectors returns "ERR" when the projector is not ready to reply the command. Null command is command name for "ENTER" or "RETURN" key of the keyboard The reply is ":"
All commands are executable.

4.1.Standby state
A command should be sent after receiving the colon of the previous command from the projector. The following is an exception. When the PWR OFF command is sent to 7800/7850/8300/9300 with the standby configuration of “network off”, the subsequent command should be sent 10 seconds after the colon is received. In case that you can not wait for the colon and send a command after receiving it, instead send a command after the execution time listed in the
following table.
(note1) When a projector receives the PWR ON command, it tries to ignite the lamp by activating the ballast unit. In case that the lamp fails to be ignited, it tries to ignite the lamp three times at maximum. When the lamp fails to be ignited three times, it is a lamp failure. The projector returns a colon within 40, 70 and 100 seconds when successful in the first, second and third times respectively. (note2) When the input video sync signal is stable, a colon is returned within 5 seconds. However, it may take more than 5 seconds when the input video sync signal is unstable. (note3) Projector initiates the process of the input video signal recognition when it receives a SOURCE command. If the signal of the video input is changing (for example, from SVGA to XGA by A/V controller) during the process of the input video signal recognition, the projector returns “ERR”. (note 4) Projectors execute the PWR OFF command after they start completely. (note 5) Projectors might return "ERR" when "Quick Setup" and "Auto Focus" functions are set to ON.
Projector executes commands normally while a warning indicator such as a high temperature warning is on. Projector does not execute commands nor return a colon when the projector is in an abnormal state such as a lamp failure and abnormal high temperature. As for EMP-6100/6000 and EMP-1715/1710/1705/1700, when an abnormal state is continued for 130 seconds after, PWR ON command becomes possible.

(OSupported -Not supported)

6.1.Command table 1 ( Fixed parameter)




Set commands Get commands Parameter for set (Return code for get) Models Function
CMODE xx CMODE? 01 : sRGB 02 : Normal 03 : Meeting 04 : Presentation 05 : Theater 06 : Amusement
30/52 73/53 720/730 735 600/800/810/811/820
54/74 61/81 740/745 732/737 821/828 765/760 755/750
- LAMP? 0-65535 All models Return the lamp hour
LUMINANCE xx LUMINANCE ? 00 : High 01 : Low 73/53/74/54 7800/7850 8300/9300 61/81 830/835 740/745 821/828 7900/7950 732/737 S3/S4 765/760 755/750 62/82 X3(76) 6100/6000 1715/1710/1705/1700
All models Set A/V Mute
All models except 600/800/ 810/811/820 Set freeze
All models Set rear projection
All models Set ceiling projection

Set commands Get commands Parameter for set (Return code for get) Models Function
600/800/810/811/820 Select audio input
KEY xx - 4A All models except 600/800/ 810/811/820 Perfrom”Auto-sync” of a remote control button
47 Perfrom”Freeze” of a remote control button
CCAP xx CCAP? 00 : OFF 11 : CC1 12 : CC2 13 : CC3 14 : CC4 21 : TEXT1 22 : TEXT2 23 : TEXT3 24 : TEXT4
6100 Select Closed Caption
FLTIME x1 x2 x1 Object of setting 00 : All objects 01 : Object 1 02 : Object 2 03 : Object 3 x2 Set time 0 : 1-100 (100H) 1 : 101-200 (200H) I 14 : 1401-1500 (1500H)*
6100 Setting of use time of air filter *The maximum value depends on the kind of the air filter and the upper bound value is different.
FILTER? 0-65535 6100 Acquisition of use time of air filter
7800/7850 7900/7950 · 6100/6000 · 1715/1705

Set commands Initial value Steps Models Function
VOL xx 15 0 - 31 600/800/810/811/820 Set the volume level
10 0 - 20 720/730/735
10 0 - 20 30/52
10 0 - 20 73/53/74/54
15 0 - 31 8300/9300
15 0 - 31 7800/7850/7900/7950
10 0 - 20 61/81
15 0 - 30 830/835
10 0 - 20 740/745/732/737765/760/755/750
10 0 - 20 821/828
10 0 - 20 62/82/X3(76)
10 0 - 20 6100/6000
10 0 - 20 1715/1710/1705/1700
TONEH xx 0 -6 - 6 600/800/810/811/820 Set bass level
0 -8 - 8 720/730/735
0 -8 - 8 30/52
0 -6 - 6 8300/9300
0 -6 - 6 7800/7850/7900/7950
0 -6 - 6 830/835
TONEL xx 0 -6 - 6 600/800/810/811/820 Set bass level
0 -6 - 6 8300/9300
0 -6 - 6 7800/7850/7900/7950
BRIGHT xx 0 -30 - 30 600/800/810/811/820 Set brightness
0 -64 - 64 720/730/735
0 -64 - 64 30/52
0 -64 - 64 73/53/74/54
0 -30 - 30 8300/9300
0 -30 - 30 7800/7850/7900/7950
0 -32 - 32 61/81
0 -30 - 30 830/835
0 -12 - 12 740/745/732/737/765/760/755/750
0 -32 - 32 821/828
0 -12 - 12 62/82/X3(76)
0 -24 - 24 S4
0 -24 - 24 6100/6000
0 -24 - 24 1715/1710/1705/1700

Set commands Initial value Steps Models Function
CONTRAST xx 0 -30 - 30 600/800/810/811/820 Set contrast
0 -32 - 32 720/730/735
0 -32 - 32 30/52
0 -32 - 32 73/53/74/54
0 -30 - 30 8300/9300
0 -30 - 30 7800/7850/7900/7950
0 -32 - 32 61/81
0 -30 - 30 830/835
0 -32 - 32 740/745/732/737/765/760755/750
0 -32 - 32 821/828
0 -12 - 12 62/82/X3(76)
0 -24 - 24 S4
0 -24 - 24 6100/6000
0 -24 - 24 1715/1710/1705/1700
TINT xx 0 -15 - 15 600/800/810/811/820 Set tint
0 -15 - 15 720/730/735
0 -32 - 32 30/52
0 -32 - 32 73/53/74/54
0 -15 - 15 8300/9300
0 -5 - 5 7800/7850/7900/7950
0 -32 - 32 61/81
0 -15 - 15 830/835
0 -32 - 32 740/745/732/737/765/760/755/750
0 -32 - 32 821/828
0 -32 - 32 62/82/X3(76)
0 -32 - 32 6100/6000
0 -32 - 32 1715/1710/1705/1700
VKEYSTONE xx 0 -60 - 59 600/800/810/811/820 Set vertical keystone value
0 -30 - 30 720/730/735
0 -30 - 30 30/52
0 -30 - 30 73/53/74/54
0 -64 - 64 8300/9300
0 -64 - 64 7800/7850/7900/7950
0 -30 - 30 61/81
0 -64 - 64 830/835
0 -30 - 30 740/745/732/737/765/760755/750
0 -30 - 30 821/828
0 -60 - 60 62/82/X3(76)
0 -60 - 60 6100/6000
0 -60 - 60 1715/1710/1705/1700
HKEYSTONE xx 0 -29 - 29 600/800/810/811/820 Set horizontal keystone value
0 -39 - 39 7800/7850/7900/7950
0 -64 - 64 830/835

7.1.Communication specification.
A projector and a computer can be connected using a serial or USB port. The projector can be remotely controlled by sending commands to the projector.


Projector PC serial cable Computer GND 5 5 GND RD 2 3 TD TD 3 2 RD
*DTR and DSR are not used.

USB COM Driver Models EMPUSBSetup.exe 600/800/810/811/820/720/730/520/73/53/74/54/735 EMPUSB2Setup.exe 7800/7850/8300/9300/61/81/830/835/740/745/732/737/ 821/828/7900/7950/S3/765/760/755/750/62/82/X3(76)S4/ 1715/1710/1705/1700


Revision Issued Date Page Description
A Sep 16,2005 All pages First release.
B Oct 19,2005 All pages. Correction of disclaimer. Model EMP-755/750 addition.
C Nov 4,2005 All pages. Model EMP-62/82/X3(76) addition.
D Apr 17,2006 All pages. Model EMP-S4 addition.
E AUg 11,2006 All pages. Model EMP-6100/6000 and EMP-1715/1710/1705/1700 addition.
Pagine di riferimento in questo manuale: produttore, supporto e download.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.