IT 14.4 CARATTERISTICHEp.1SU CANNA FUMARIA CONDIVISA NO NOp.1UMIDITÀ PELLETS ≤ 10% ≤ 10%p.1POTENZA ASSORBITA RESISTENZA ACCENDITORE 300 W 300 Wp.1STUFA A CAMERA STAGNA SI SIp.114.5 DICHIARAZIONE DI CONFORMITÀp.2ITp.21 MANUAL SIMBOLOGYp.4USERp.4SPECIALIZED STOVE-REPAIRERp.4CAUTION: READ CAREFULLY THE NOTEp.4CAUTION: DANGER OR IRREVERSIBLE DAMAGE POSSIBILITYp.42 DEAR CUSTOMERp.53 CAUTIONSp.54 SPARE PARTSp.55 DISPOSALp.56 PACKAGING AND HANDLINGp.66.1 PACKAGINGp.66.2 STOVE HANDLINGp.67 CHIMNEY FLUEp.67.1 INTRODUCTIONp.67.2 CHIMNEY FLUEp.77.3 TECHNICAL FEATURESp.87.4 HEIGHT-DEPRESSIONp.97.5 MAINTENANCEp.97.6 CHIMNEY POTp.97.7 CHIMNEY COMPONENTSp.107.8 EXTERNAL AIR INLETp.117.9 COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATIONp.127.10 CHIMNEY FLUE CONNECTIONp.127.11 EXAMPLES OF CORRECT INSTALLATIONp.138 FUELp.158.1 FUELp.159 INSTALLATIONp.159.1 INTRODUCTIONp.159.2 OVERALL DIMENSIONSp.169.3 GENERAL INSTALLATION WITH PEDESTALp.179.4 PEDESTAL ASSEMBLYp.189.5 WALL MOUNTINGp.189.6 PANELS ASSEMBLY (CLOE MODEL)p.209.7 PANELS ASSEMBLY (SQUARE MODEL)p.229.8 ELECTRIC CONNECTIONp.239.9 CONNECTION TO THE EXTERNAL THERMOSTATp.249.10 VENTILATIONp.2410 USEp.2410.1 ATTENTIONp.2410.2 INTRODUCTIONp.2510.3 CONTROL PANELp.25PANEL ELEMENT DESCRIPTIONp.2510.4 USER MENUp.27POS. REFERENCE DESCRIPTIONp.273 SET CHRONOp.275 STAND-BY MODEp.277 INITIAL LOADp.2710.5 START UPp.2710.6 STOVE ADJUSTMENTp.2810.7 FAILED IGNITIONp.2810.8 POWER FAILUREp.2810.9 TEMPERATURE SETTINGp.2810.10 FUME TEMPERATUREp.2810.11 SWITCHING OFFp.2910.12 CLOCK SETTINGp.2910.13 DAILY PROGRAMMINGp.2910.14 WEEK-END PROGRAMMINGp.2910.15 WEEKLY PROGRAMMINGp.3010.16 FIRE EXTINGUISHING IN CASE OF FIREp.3010.17 PELLET SUPPLYp.3010.18 REMOTE CONTROL (OPTIONAL)p.3111 SAFETY SYSTEMp.3111.1 INTRODUCTIONp.3111.2 ”BLACK OUT” ALARMp.3111.3 ”FUME PROBE” ALARMp.3111.4 ”HOT FUME” ALARMp.3211.5 ”FAN FAILURE” ALARMp.3211.6 ”FAILED IGNITION” ALARMp.3211.7 ”NO PELLET” ALARMp.3211.8 ”THERMAL SAFETY” ALARMp.3211.9 ”FAILURE DEPRESS” ALARMp.3212 MAINTEINANCEp.3312.1 INTRODUCTIONp.33
Page 1 of the Cadel SQUARE user manual — STUFA A CAMERA STAGNA SI SI
Pagina 1 · clicca per ingrandire
Pagina 1

IT 14.4 CARATTERISTICHE

DESCRIZIONE CLOE 6,5 kW SQUARE 6,5 kW

LARGHEZZA 82 cm 82 cm

PROFONDITÁ 28,5 cm 27 cm

ALTEZZA con piedistallo 91,5 cm 92 cm

PESO con piedistallo 92-98-107 kg 92-98 kg

POTENZA TERMICA INTRODOTTA (Min/Max) 2,8 - 7,3 kW 2,8 - 7,3 kW

POTENZA TERMICA NOMINALE (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW

EFFICIENZA (Min/Max) 88 - 89,5 % 88 - 89,5 %

TEMPERATURA FUMI (Min/Max) 129 - 193 °C 129 - 193 °C

PORTATA MASSIMA DEI FUMI (Min/Max) 3,4 - 4,4 g/s 3,4 - 4,4 g/s

EMISSIONI CO (13% O2) (Min/Max) 0,049 - 0,010 % 0,049 - 0,010 %

EMISSIONI OGC (13% O2) 0,4 mg/Nm3 0,4 mg/Nm3

EMISSIONI NOX (13% O2) 118 mg/Nm3 118 mg/Nm3

EMISSIONI CO2 (Min/Max) 5,3 - 10,5 % 5,3 - 10,5 %

CONTENUTO medio di CO al 13% O2 (Min/Max) 610 - 123 mg/Nm3 610 - 123 mg/Nm3

CONTENUTO medio di POLVERI al 13% O2 (Max) 16 mg/Nm3 16 mg/Nm3

DEPRESSIONE CAMINO (Min/Max) 11 - 12 Pa 11 - 12 Pa

DISTANZA MINIMA di sicurezza da materiali infiammabili 30 cm 30 cm

SU CANNA FUMARIA CONDIVISA NO NO

DIAMETRO SCARICO FUMI Ø80 mm Ø80 mm

COMBUSTIBILE Pellet Ø6-7 mm Pellet Ø6-7 mm

POTERE CALORIFICO PELLETS 5 kWh/kg 5 kWh/kg

UMIDITÀ PELLETS ≤ 10% ≤ 10%

VOLUME RISCALDABILE 18/20°C Coeff. 0,045 kW (Min/Max) 60 - 156 m3 60 - 156 m3

CONSUMO ORARIO (Min/Max) 0,6 - 1,5 kg/h 0,6 - 1,5 kg/h

CAPACITÀ SERBATOIO 8 kg 8 kg

AUTONOMIA (Min/Max) 13,3 - 5,3 h 13,3 - 5,3 h

ALIMENTAZIONE 230 V - 50 Hz 230 V - 50 Hz

POTENZA ASSORBITA (Max) 350 W 350 W

POTENZA ASSORBITA RESISTENZA ACCENDITORE 300 W 300 W

PRESA D’ARIA ESTERNA MINIMA (sezione utile ultima) 80 cm2 80 cm2

STUFA A CAMERA STAGNA SI SI

PRESA D’ARIA ESTERNA PER CAMERA STAGNA Ø60 mm Ø60 mm

Page 2 of the Cadel SQUARE user manual — 14.5 DICHIARAZIONE DI CONFORMITÀ
Pagina 2 · clicca per ingrandire
Pagina 2

14.5 DICHIARAZIONE DI CONFORMITÀ

IT

Cadel SQUARE — 14.5 DICHIARAZIONE DI CONFORMITÀ diagram (page 2)
Fig. 1

Fig. 60 - Dichiarazione di Conformità

Page 3 of the Cadel SQUARE user manual — 14.5 DICHIARAZIONE DI CONFORMITÀ
Pagina 3 · clicca per ingrandire
Pagina 3
Page 3 of the Cadel SQUARE user manual — 14.5 DICHIARAZIONE DI CONFORMITÀ
Page 4 of the Cadel SQUARE user manual — CAUTION: DANGER OR IRREVERSIBLE DAMAGE POSSIBILITY
Pagina 4 · clicca per ingrandire
Pagina 4

1 MANUAL SIMBOLOGY

  • The icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the User and/or the Authorized Technician and/or the Specialized Stove-repairer).
  • WARNING symbols indicates an important note.
Cadel SQUARE — 1 MANUAL SIMBOLOGY diagram (page 4)
Fig. 2

USER

Cadel SQUARE — USER diagram (page 4)
Fig. 3

AUTHORISED TECHNICIAN (ONLY to interpret or the Stove-manufacturer or the Authorized Technician of

Technical Assistance Service approved by the Stove-manufacturer)

Cadel SQUARE — USER diagram (page 4)
Fig. 4

SPECIALIZED STOVE-REPAIRER

Cadel SQUARE — SPECIALIZED STOVE-REPAIRER diagram (page 4)
Fig. 5

CAUTION: READ CAREFULLY THE NOTE

Cadel SQUARE — CAUTION: READ CAREFULLY THE NOTE diagram (page 4)
Fig. 6

CAUTION: DANGER OR IRREVERSIBLE DAMAGE POSSIBILITY

Page 5 of the Cadel SQUARE user manual — 5 DISPOSAL
Pagina 5 · clicca per ingrandire
Pagina 5

2 DEAR CUSTOMER

  • Our products are designed and manufactured in compliance with standards EN 13240 for wood stoves, EN 14785 for pellet stoves, EN 13229 for fire places, EN 12815 for wood cooker stoves, Dir.89/106/CEE for manufacturing products, Re n.1935/2004 for materials and objects which are in contact with foods, Dir. 2006/95/CEE for low tension, Dir.2004/108/EC for Electromagnetic compatibility.
  • Read carefully the instruction contained in this manual to obtain the best efficiency.
  • This instruction manual is an integral part of the product: make sure it is delivered with the appliance also in case of sold to others. In case of loss please ask a copy to your local Technical Assistance Service.
  • All local regulations, including those referring to national European standards, must be respected during appliance installation.

In Italy biomass system installation below 35 kW must comply with MD 37/08. Every qualified installer who own these requirements, has to issue the certificate of conformity for the installed system (“system” means: stove + chimney + air inlet).

  • According to (EU) No. 305/2011 regulation, the “ Declaration of Performance” is available online at the web sites <a href="http://www.cadelsrl.com" rel="nofollow noopener" target="_blank">www.cadelsrl.com</a> / <a href="http://www.free-point.it" rel="nofollow noopener" target="_blank">www.free-point.it</a>

3 CAUTIONS

  • All the pictures carried in this manual are only for indicative and explanatory purpose and could therefore slightly differ from your appliance.
  • The referring appliance is those you purchased.
  • In case of doubts or difficulties in the comprehension or for problems not described in this manual, please promptly contact your distributor or installer.
  • It is forbidden to modify the appliance without authorization.

4 SPARE PARTS

  • For each repair or adjustment which should be necessary, please contact the dealer where you purchased your stove or your nearest Technical Assistance Service, specifying:
  • Appliance model
  • Serial number
  • Type of problem Use only original spare parts which you can find at our Technical Assistance Services.

5 DISPOSAL

Fig. 1 - Disposal

This symbol on the product means that used electric and electronic products must not be mixed with domestic waste. For a proper disposal, recovery and/or recycling, please take this product to an authorized waste collection points, where they will be accepted for free. For further instructions, please contact your local authority or your nearest waste collection point. In case of wrong disposal of this waste material there could be applied penalties as provided by national laws.

(European directive 2002/96/CE)

Page 6 of the Cadel SQUARE user manual — 7.1 INTRODUCTION
Pagina 6 · clicca per ingrandire
Pagina 6

6 PACKAGING AND HANDLING

6.1 PACKAGING

  • The packaging is made up of recyclable cardboard boxes according to RESY standards, recyclable expanded polystyrene inserts and wooden pallets.
  • All packaging materials can be re-used for a similar use or eventually discharged as waste assimilable to the municipal solid ones, in accordance with current regulations.
  • After having removed the packaging please assure you about the integrity of the product.

Packaging are not toys and could cause suffocation or strangulation and other health hazards! People (childreen included) with reduced mobility, psycological deseases or without experience and knowledge must be kept away from packaging. The stove is not a toy, please see ATTENTION page 74.

6.2 STOVE HANDLING

  • Both whether the stove is packed or not it is necessary to observe the following instructions for handling and transporting the stove from its sale point to its installation point and for any future movements:
  • The stove must be handled with idoneous means paying attention to the existing safety regulations;
  • do not turn the stove upside down and/or upset it on one side, but keep it in vertical position or as accorded with the constructor instructions;
  • if the stove is made up of ceramic, stone, glass or any particularly fragile material components, all must be moved with the utmost care.

7 CHIMNEY FLUE

7.1 INTRODUCTION

This chapter about the Chimney Flue has been drawn up in cooperation with Assocosma (www.assocosma. org) and is based on European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443 - UNI 10683:2012). It provides instructions for a good and correct execution of the chimney flue but it does not absolutely replace the current standards which the qualified manufacturer/installer should comply with.

Please check with your local authorities if exists any restrictive regulation which regards the combustible air inlet, the fumes exhaust system, the chimney flue and the chimney pot.

The company declines any responsibility regarding the bad running of the stove if it is due to the use of a no correctly dimensioned chimney flue which does not respect current regulations.

Page 7 of the Cadel SQUARE user manual — 7.2 CHIMNEY FLUE
Pagina 7 · clicca per ingrandire
Pagina 7

7.2 CHIMNEY FLUE

Cadel SQUARE — 7.2 CHIMNEY FLUE diagram (page 7)
Fig. 7

Fig. 2 - Chimney Flues

LEGEND Fig. 2 page 57 1 Chimney flue with insulated stainless-steel pipes 2 Chimney flue on the existing chimney 3 Inspection plug 4 Inspection door 5 ≥ 3,5 mt

  • The chimney flue or chimney is of great importance for the correct running of the heating appliance.
  • It is fundamental that the chimney flue is perfectly built and always maintained with a perfect efficiency.
  • The chimney flue must be sole (see Fig. 2 page 57 ) with insulated stainless-steel pipes (1) or installed on the existing chimney flue (2).
  • Both this solutions must be endowed with an inspection plug (3) and/or an inspection door (4).

It is forbidden to connect more pellet stoves or any other heating appliance to the same chimney flue.

Page 8 of the Cadel SQUARE user manual — 7.3 TECHNICAL FEATURES
Pagina 8 · clicca per ingrandire
Pagina 8

7.3 TECHNICAL FEATURES

Cadel SQUARE — 7.3 TECHNICAL FEATURES diagram (page 8)
Fig. 8

Fig. 3 - Inclined roof

LEGEND Fig. 3 page 58 1 Height over the ridge of the roof = 0,5 mt 2 Roof inclination ≥ 10° 3 90° 4 Measured distance at 90° from the roof surface = 1,3 mt

  • The chimney flue must be sealed from fumes.
  • It must have a vertical run without narrowing. It must be realized with fume and condensation resistant materials with thermal insulation and able to last against usual mechanical stresses.

It must be insulated to avoid condensation and to reduce fume cooling effects.

  • The stove must be spaced out from fuels or flammable materials with an air gap or with insulating materials. Check the distance with the chimney manufacturer.
  • The chimney entrance must be placed in the same room where the appliance is installed or otherwise in the adjacent room and it must be provided with a solid and condensation collection chamber under the entrance, accessible through the sealed metal gate.
  • Auxiliary exhaust fans cannot be installed neither along the chimney nor on the chimney pot.
  • The inner section of the chimney flue can be round (the best one) or square and the jointed sides must have a minimum radius of 20 mm.
  • The section dimension must be minimum Ø120 mm and maximum Ø180 mm.
  • Made the efficiency of the chimney flue overhauled by an expert stove-repairer and if necessary cover the chimney flue with materials in compliance with current regulations.
  • The flue system must be placed on the roof.
  • The chimney flue must be provided CE in accordance with EN 1443 regulation. Please find attached an example of label:
Page 9 of the Cadel SQUARE user manual — 7.6 CHIMNEY POT
Pagina 9 · clicca per ingrandire
Pagina 9
Cadel SQUARE — 7.4 HEIGHT-DEPRESSION diagram (page 9)
Fig. 9

Fig. 4 - Example of label

7.4 HEIGHT-DEPRESSION

The depression (draught) of a chimney flue depends also on its height. Check the depression with the values provided at FEATURES page 98. Minimum height 3,5 meters.

7.5 MAINTENANCE

  • The chimney flue must be cleaned, since the soot and unburnt oil deposits reduce its section so blocking the draught. In great quantities they can flare up.
  • The fumes extraction pipes (fumes conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the directives of your insurance company.
  • In case of doubts, please follow the most restrictive regulations.
  • Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once a week. The chimney sweep has to release a written declaration about the security of the system.
  • Not cleaning compromise safety.

7.6 CHIMNEY POT

Cadel SQUARE — 7.6 CHIMNEY POT diagram (page 9)
Fig. 10

Fig. 5 - Anti-wind chimney pots

  • The chimney pot is important for the correct running of the heating appliance:
  • We recommend using an anti-wind chimney pot, see Fig. 5 page 59 .
  • The hole width for fumes exhaust must be the double of the chimney flue width and fitted in a way that the fume exhaust is assured also in case of wind.
  • It should prevent the infiltration of rain, snow and animals.
  • The outlet height in the atmosphere must be away from the reflux area caused by the roof structure or by obstacles laying nearby (see Fig. 3 page 58 ).
Page 10 of the Cadel SQUARE user manual — 7.7 CHIMNEY COMPONENTS
Pagina 10 · clicca per ingrandire
Pagina 10

7.7 CHIMNEY COMPONENTS

Cadel SQUARE — 7.7 CHIMNEY COMPONENTS diagram (page 10)
Fig. 11

Fig. 6 - Chimney components

LEGEND Fig. 6 page 60 1 Chimney pot 2 Fume outlet 3 Chimney flue 4 Termal insulation 5 External wall 6 Chimney union 7 Fume pipe 8 Heat generator 9 Inspection door 10 T-union with inspection plug

Page 11 of the Cadel SQUARE user manual — 7.8 EXTERNAL AIR INLET
Pagina 11 · clicca per ingrandire
Pagina 11

7.8 EXTERNAL AIR INLET

Cadel SQUARE — 7.8 EXTERNAL AIR INLET diagram (page 11)
Fig. 12
Cadel SQUARE — 7.8 EXTERNAL AIR INLET diagram (page 11)
Fig. 13

Fig. 7 - Direct air inflow Fig. 8 - Indirect air inflow

LEGEND Fig. 7 page 61|Fig. 8 page 61 1 Room to ventilate 2 Adjacent room 3 External air inlet 4 Cleft under the door

  • The room must be endowed with an external air recycling for a good climate in your ambient.
  • The air inflow from outside to the inner occurs directly, through an opening on the external wall of the room (see Fig. 7 page 61 ); otherwise it occurs indirectly by air suction from rooms adjacent to the one to ventilate (see Fig. 8 page 61 ).
  • Bedrooms, garages, and store of flammable materials are excluded.
  • The air inlet should have a total net surface of 80 sqcm2: the aforesaid surface is to widen if inside the room there are other activated appliances (for example: electric ventilators for foul air suction, cooker hoods, other stoves, etc...) which depress the environment.
  • At switched on appliance it is necessary to check that the pressure fall between the room and the outside does not exceed 4,0 Pa value: if necessary widen the air inlet (EN 13384).
  • The air inlet must be realized at a height close to the floor with an external grid against birds. In such a way it cannot be obstructed by any object.
  • In case of installation with sealed-chamber the air inlet is not necessary.
Page 12 of the Cadel SQUARE user manual — 7.10 CHIMNEY FLUE CONNECTION
Pagina 12 · clicca per ingrandire
Pagina 12

7.9 COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION

Cadel SQUARE — 7.9 COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION diagram (page 12)
Fig. 14

Fig. 9 - Air inlet for sealed-chamber installation

LEGEND Fig. 9 page 62 1 ≥ 1,5 mt 2 ≥ 0,3 mt 3-3 Sectional view 4 Shield grid 5 Curve inlet to turn downwards

  • Check FEATURES page 98 if the purchased stove has a sealed-chamber. If the stove is endowed with a sealed-chamber and you want also the whole installation with sealed chamber, please read the following instructions:
  • It is necessary to extract the air for combustion directly from outside.
  • Use a tube with minimum Ø60 mm and maximum 2 meters lenght; to connect see the back of the stove.
  • During installation step is necessary to verify the minimum distances required for the combustible air inlet as (for example) an open door or window causes a vortex which could remove the combustible air necessary to the stove (see the underlying scheme).
  • On the external wall it is necessary to install a curve at 90° to protect the combustible air inflow from wind effects: turn the curve inlet downwards, see Fig. 9 page 62 .
  • Endow the curve with an external shield grid against birds in such a way that it cannot be obstructed by any object.
  • Caution: check with your local authorities if exists any restrictive regulation regarding the combustible air inlet: if present, they must be applied. In some countries and/or regions the installation with sealedchamber is obligatory: in case of doubt, please follow the most restrictive regulations.

7.10 CHIMNEY FLUE CONNECTION

Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by specialized personnel or companies as provided by UNI 10683:2012. • The connection between the appliance and the chimney flue should be short in order to favor the

Page 13 of the Cadel SQUARE user manual — 7.11 EXAMPLES OF CORRECT INSTALLATION
Pagina 13 · clicca per ingrandire
Pagina 13
  • draught and to avoid condensation in the pipes.
  • The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
  • Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is sealed with the plug given with standard equipment.

SYSTEM TYPE Ø80 mm PIPE Ø100 mm PIPE

Minimum vertical length 1,5 mt 2 mt

Maximum length (with 1 union) 6,5 mt 10 mt

Maximum length (with 3 unions) 4,5 mt 8 mt

Maximum number of unions 3 3

Level section (minimum inclination 3%) 2 mt 2 mt

Installation at a height above 1200 m a.s.l. NO Obligatory

  • Use a plate pipe for stoves of Ø80 mm or Ø100 mm depending on the type of system and with silicone gaskets.
  • It is forbidden to use metal, fibre cement or aluminium flexible pipes.
  • For change of direction it is obligatory always to use a union (with angle > 90°) with inspection plug which enables an easy periodic cleaning of the pipes.
  • Please assure you that after the cleaning the inspection plugs are sealed with its efficient gasket.
  • It is forbidden to connect more appliances to the same fume conduit.
  • It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
  • It is forbidden to exhaust flue gases directly from the wall towards the outside and closed spaces also at open top.
  • It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
  • The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible components.

7.11 EXAMPLES OF CORRECT INSTALLATION

Cadel SQUARE — 7.11 EXAMPLES OF CORRECT INSTALLATION diagram (page 13)
Fig. 15

Fig. 10 - Example 1

Page 14 of the Cadel SQUARE user manual — 7.11 EXAMPLES OF CORRECT INSTALLATION
Pagina 14 · clicca per ingrandire
Pagina 14

LEGEND Fig. 10 page 63 1 Insulating material 2 Reduction from Ø100 to Ø80 mm 3 Inspection plug 4 Minimum safety distance = 0,5 mt

  • Chimney flue installation Ø120 mm with an enlarged drilling for pipe transit.
Cadel SQUARE — 7.11 EXAMPLES OF CORRECT INSTALLATION diagram (page 14)
Fig. 16

Fig. 11 - Example 2

LEGEND Fig. 11 page 64 1 Insulating material 2 Inspection plug 3 Chimney inspection entrance 4 Minimum safety distance = 0,5 mt 5 Inclination ≥ 3° 6 Level section ≤ 1 mt

  • Old chimney flue with an inserted pipe of minimum Ø120 mm and with an external door which enables the chimney cleaning.
Cadel SQUARE — 7.11 EXAMPLES OF CORRECT INSTALLATION diagram (page 14)
Fig. 17

Fig. 12 - Example 3

Page 15 of the Cadel SQUARE user manual — 9.1 INTRODUCTION
Pagina 15 · clicca per ingrandire
Pagina 15

LEGEND Fig. 12 page 64 1 Insulating material 2 Inspection plug 3 Minimum safety distance = 0,5 mt

  • External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø120 mm: all must be firmly attached to the wall. For chimney against wind effects please (see Fig. 5 page 59 ).
  • Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.

We recommend to check with your chimney flue manufacturer the safety distances which must be respected and the type of insulating material. The aforesaid regulations are valid also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).

8 FUEL

8.1 FUEL

  • The type of fuel to use is only the pellets.
  • Use top-quality pellets because they have influence in the calorific value and in ash remains.
  • Pellets features are: dimension Ø6-7mm (D06 Class), maximum lenght 40 mm, calorific value 5kWh/ kg, humidity ≤ 10%, ash remains ≤ 0,7%, they must be correctly pressed and not much mealy, without sizing agents, resins and other additives (it is advisable to use pellets in compliance with the regulation EN14961-2 type ENplus-A1 ).
  • Not adequate pellets cause a bad combustion, a frequent burning pot obstruction and exhaust conduits obstruction. Further it decreases the calorific value, soils the glass and increases consumptions and ash and unburnt granules quantity.

Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and far at least one meter from the stove and/or any other source of heat.

  • It is advisable to try different type of pellets available on the market and to choose that which gives the best performance.
  • The use of bad quality pellets can damage the stove so that the warranty and manufacturer liability fall.
  • Do not use the appliance as waste inceneretor.
  • On all our product are used high-quality materials such as stainless-steel, steel, cast iron, etc... These materials, before being sold on the market, are tested in laboratory, but despite this on the components which enable the pellets flow (auger) there could exist minimum differences in the material used, in roughness and porosity, which could generate usual variations in fuel transportation (pellets), causing a flame raising or drapping with a possible switching off at lower powers.
  • Depending on the type of pellets it could be necessary a parameters adjustment, please contact an Authorized Assistance Service.

9 INSTALLATION

9.1 INTRODUCTION

  • The assembly position must be chosen depending on environment, outlet, chimney flue.
Page 16 of the Cadel SQUARE user manual — 9.2 OVERALL DIMENSIONS
Pagina 16 · clicca per ingrandire
Pagina 16
  • Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation, fume exhaust system together with chimney flue and chimney pot.
  • The manufacturer declines any responsibility in case of installation which are not in compliance with current regulations, in case of a wrong room ventilation system, in case of an electric connection which is not in compliance with regulations and in case of a wrong use of the appliance.
  • The installation must be executed by an authorized technician, who must release to the user a declaration of conformity of the system and will assume the whole responsibility on the final installation and on the resulting good running of the product.
  • As equipment with the stove there is a testing and maintenance manual which must be periodically executed by the installer.
  • Check if there is the combustible air inlet.
  • Check the probable presence of other stoves or appliances which could depress the room (see EXTERNAL AIR INLET page 61 ).
  • Check at switched on stove if there is the presence of CO in the room.
  • Check if the chimney has the necessary draught.
  • Check if during the fume passage all has been executed in safety (probable fume losses and distances from flammable materials, etc.…).
  • The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney flue cleaning.
  • The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION page 73 ).
  • It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible materials and in one-room flats.
  • The installation in one-room flats is allowed if they are in sealed chamber.
  • In any case the stove must not be installed in rooms where it can get in touch with water or water splashes because this can cause burn hazards and short-circuit.
  • To install more appliances, the external air inlet must be correctly dimensioned (see EXTERNAL AIR INLET page 61 ).

9.2 OVERALL DIMENSIONS

Cadel SQUARE — 9.2 OVERALL DIMENSIONS diagram (page 16)
Fig. 18

Fig. 13 - General dimensions

Page 17 of the Cadel SQUARE user manual — 9.3 GENERAL INSTALLATION WITH PEDESTAL
Pagina 17 · clicca per ingrandire
Pagina 17

LEGEND Fig. 13 page 66 1 Hole combustion air inlet d.6 cm 2 Exhaust fumes d.8 cm 3 80,3 cm 4 76,5 cm 5 15,8 cm 6 26,8 cm 7 6,5 cm 8 8,5 cm 9 8,2 cm 10 71 cm 11 8,5 cm 12 20,5 cm 13 33 cm

9.3 GENERAL INSTALLATION WITH PEDESTAL

Cadel SQUARE — 9.3 GENERAL INSTALLATION WITH PEDESTAL diagram (page 17)
Fig. 19

Fig. 14 - General installation with pedestal

LEGEND Fig. 14 page 67 1 Stove 2 Minimum lateral distance = 300 mm 3 Minimum rear distance = 200 mm 4 Minimum front distance = 1000 mm

  • Please check that the floor has an adequate load capacity. If the existing one does not satisfy this requirement, appropriate measure should be provided (for example a plate for distributing the load).
  • It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good distribution of heat in the room (see Fig. 14 page 67 ).
  • For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of furniture, wooden covering, etc...) must be respected, has described in Fig. 14 page 67 .
  • If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be further increased with 1 meter.
  • If the walls are made up of flammable materials, check the safety distances (see Fig. 14 page 67 ).
  • At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary please install a fire resistant plate on the concerned walls.
  • In some countries also masonring load-bearing walls are considered flammable.
Page 18 of the Cadel SQUARE user manual — 9.5 WALL MOUNTING
Pagina 18 · clicca per ingrandire
Pagina 18

9.4 PEDESTAL ASSEMBLY

Cadel SQUARE — 9.4 PEDESTAL ASSEMBLY diagram (page 18)
Fig. 20
Cadel SQUARE — 9.4 PEDESTAL ASSEMBLY diagram (page 18)
Fig. 21

Fig. 15 - Assembling the pedestal Fig. 16 - Stove on the pedestal

  • Lay the stove on the floor horizontally.
  • Place pedestal and, using the Allen key provided, tighten the no.4 M6 screws under the pedestal (see Fig. 15 page 68 ).
  • Put the stove upright (see Fig. 16 page 68 ).

9.5 WALL MOUNTING

The stove is suitable for wall mounting. The can be attached to a load-bearing wall in masonry (NOT plasterboard, wood, etc...) suitable for the entire weight of the stove.

Cadel SQUARE — 9.5 WALL MOUNTING diagram (page 18)
Fig. 22

Fig. 17 - Wall mounting

LEGEND Fig. 17 page 68 1 Stove 2 Minimum lateral distance = 300 mm 3 Minimum front distance = 1000 mm

  • It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides to enable an eficient appliance cooling and a good distribution of heat in the room (see Fig. 17 page 68 ).
  • For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of furniture, wooden covering, etc...) must be respected, has described in Fig. 17 page 68 .
  • If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be further increased with 1 meter.

In some countries also masonring load-bearing walls are considered flammable.

Page 19 of the Cadel SQUARE user manual — 9.4 PEDESTAL ASSEMBLY
Pagina 19 · clicca per ingrandire
Pagina 19
  • If you want to fix the stove to a non-flammable material wall, you need to fix the support to the wall (the support is provided with the stove).
  • Call an expert to prepare the fumes outlet hole and the combustion air inlet hole.
  • To fix the rear support to the wall with metal plugs su1itable for the weight of the stove (see Fig. 18 page 69 ).
Cadel SQUARE — 9.4 PEDESTAL ASSEMBLY diagram (page 19)
Fig. 23

Fig. 18 - Mounting on non-flammable wall

LEGEND Fig. 18 page 69 1 695 mm 2 179 mm 3 260 mm 4 202 mm 5 710 mm 6 206 mm 7 332 mm 8 Wall support 9 Metal plugs 10 Fumes outlet hole d.120 mm 11 Combustion air inlet hole d.80 mm

  • If the stove is to be fixed to an inflammable wall, it is compulsory to attach further support to the wall cod. WAL0002 (the suppurt is NOT provided with the stove).
  • Call an expert to prepare the fumes outlet hole and the combustion air inlet hole.
  • To fix the rear support to the wall with metal plugs su1itable for the weight of the stove (see Fig. 19 page 70 ).
Page 20 of the Cadel SQUARE user manual — 9.6 PANELS ASSEMBLY (CLOE MODEL)
Pagina 20 · clicca per ingrandire
Pagina 20
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 20)
Fig. 24

Fig. 19 - Mounting on flammable wall

LEGEND Fig. 19 page 70 1 695 mm 2 179 mm 3 260 mm 4 202 mm 5 710 mm 6 206 mm 7 332 mm 8 Wall support 9 M8x20 bolt 10 Fumes outlet hole d.120 mm 11 Combustion air inlet hole d.80 mm 12 Spacer (WAL0002 code) 13 Metal plugs 14 735 mm 15 159 mm

9.6 PANELS ASSEMBLY (CLOE MODEL)

Assembly must be carried out by an authorised technician.

For panels installation, proceed as follows:

Page 21 of the Cadel SQUARE user manual — 9.6 PANELS ASSEMBLY (CLOE MODEL)
Pagina 21 · clicca per ingrandire
Pagina 21
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 21)
Fig. 25
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 21)
Fig. 26

Fig. 20 - Countersunk screw Fig. 21 - Threaded seat

  • INside the panel there are 4 threaded (see Fig. 21 page 71 ) seats for screwing no.4 M5x10 countersunk screws (see Fig. 20 page 71 ). Make sure the screws sufficiently project from the panel in order to insert them in the relevant slots on the stove body.
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 21)
Fig. 27
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 21)
Fig. 28

Fig. 22 - Lower slots Fig. 23 - Lower panel insert

  • Insert and lay the screws in the relevant slots on the stove body (see Fig. 22 page 71 ).
  • Slide the panel downwards in order for all 4 screws to firmly lay on their seats (see Fig. 23 page 71 ).
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 21)
Fig. 29
Cadel SQUARE — 9.6 PANELS ASSEMBLY (CLOE MODEL) diagram (page 21)
Fig. 30

Fig. 24 - Side slots Fig. 25 - Side panels insert

  • At this point assembly the side panels. Proceed as previous steps (see Fig. 24 page 71 and Fig. 25 page 71 ).
  • Assembly upper panel at the end, the procedure depends on its material:
  • glass panel (follow A instructions),
  • metal or stove panel (follow B instructions).
Page 22 of the Cadel SQUARE user manual — 9.7 PANELS ASSEMBLY (SQUARE MODEL)
Pagina 22 · clicca per ingrandire
Pagina 22
Cadel SQUARE — 9.7 PANELS ASSEMBLY (SQUARE MODEL) diagram (page 22)
Fig. 31

Fig. 26 - Upper slots

Cadel SQUARE — 9.7 PANELS ASSEMBLY (SQUARE MODEL) diagram (page 22)
Fig. 32
Cadel SQUARE — 9.7 PANELS ASSEMBLY (SQUARE MODEL) diagram (page 22)
Fig. 33

Fig. 27 - Glass upper panel Fig. 28 - M5x6 cylinder head screw

A. Proceed as previous steps and fix on the 2 upper slots (see Fig. 26 page 72) no.2 M5x6 cylinder head

screws (see Fig. 27 page 72 and Fig. 28 page 72)

Cadel SQUARE — 9.7 PANELS ASSEMBLY (SQUARE MODEL) diagram (page 22)
Fig. 34

Fig. 29 - Metal upper panel Fig. 30 - M5x10 countersunk screw

Proceed as previous steps and fix on the 2 upper slots (see Fig. 26 page 72) no.2 M5x10 countersunk screws (see Fig. 29 page 72 and Fig. 30 page 72).

9.7 PANELS ASSEMBLY (SQUARE MODEL)

Assembly must be carried out by an authorised technician.

For panels installation, proceed as follows:

Page 23 of the Cadel SQUARE user manual — 9.8 ELECTRIC CONNECTION
Pagina 23 · clicca per ingrandire
Pagina 23
Cadel SQUARE — 9.8 ELECTRIC CONNECTION diagram (page 23)
Fig. 35
Cadel SQUARE — 9.8 ELECTRIC CONNECTION diagram (page 23)
Fig. 36

Fig. 31 - Panels assembly Fig. 32 - Panels fixing

  • Insert the metal side panles from above, placing the two teeth on the special slots and pushing all the way down (see Fig. 31 page 73 ).
  • Use no.8 wrench to tightenthe two screws under the panel (see Fig. 32 page 73 ).

9.8 ELECTRIC CONNECTION

  • The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension specific of every model, as described in the technical datas table (see FEATURES page 98 ).
  • The plug must be easily accessible when the appliance is installed.

The cable must not get in touch with the fume exhaust pipe and nor with every other part of the stove.

  • Please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not efficient, please endow you with one in compliance with the law.
  • Connect the supply cable first on the back of the stove (see Fig. 33 page 73 ) and then at a wall electric socket.
Cadel SQUARE — 9.8 ELECTRIC CONNECTION diagram (page 23)
Fig. 37

Fig. 33 - Electric socket with master switch

  • The master switch O/I (see Fig. 33 page 73 ) is to open only to switch the stove on, otherwise it is advisable to keep it off.
  • Do not use extension cables.
Page 24 of the Cadel SQUARE user manual — 10.1 ATTENTION
Pagina 24 · clicca per ingrandire
Pagina 24
  • If the feeder cable is damaged, it must be replaced by an authorized technician.
  • When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall.

9.9 CONNECTION TO THE EXTERNAL THERMOSTAT

  • The stove works through a thermostat probe placed in its inner. If you desire, the stove can be connected to an external room thermostat. This operation must be executed by an authorized technician. For connection see WIRING SCHEME page 94 :
  • external thermostat: set up a temperature which is round 7°C.
  • External chronothermostat: set up a temperature which is round 7°C and desable the chrono functions from the menu 03-01.

9.10 VENTILATION

  • The stove is endowed with a ventilation system.
  • The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses to the materials which make it up.
Cadel SQUARE — 9.10 VENTILATION diagram (page 24)
Fig. 38

Fig. 34 - Do not cover air slits

Do not cover the hot air outlet slits with any object to avoid stove’s overheating!

The stove is not suitable for food cooking.

10 USE

10.1 ATTENTION

This appliance must not be used by people (childreen included) with reduced mobility, psycological deseases or without experience and knowledge except in case of supervision or instruction about the use of the appliance by people responsible for their safety.

Page 25 of the Cadel SQUARE user manual — 10.3 CONTROL PANEL
Pagina 25 · clicca per ingrandire
Pagina 25

Childreen must be constantly overseen in order to assure that they do not play with the appliance.

The stove is provided with a hand rejector: this rejector can be removed exclusively by the stove manufacturer or by the Technical Assistance Service.

During its running, the stove reaches high temperatures: keep away childreen and animals and for your safety please use appropriate fireproof devices, such as heat- protecting gloves.

10.2 INTRODUCTION

  • To have the best performance with the lowest consumption please follow the here descripted instructions.
  • The lightning of the pellets occurs very easily if the installation is correct and if the chimney flue is efficient.
  • Switch on the stove at Power 1 for at least 2 hours in order to enable the materials which make up the boiler and the fireplace to adjust the inner springing stress.
  • Oily plant waste and lacquers can cause smells and smoke during the first working hours: it is advisable to ventilate the room because they could be noxious to people and animals.
  • By using the stove the varnish inside the combustion chamber could be subjected to alterations. This occurrence can be attributed to different reasons: an excessive stove overheating, the presence of chemical agents in bad quality pellets, bad chimney draught, etc. Therefore varnish endurance in the combustion chamber cannot be guarantee.

Set values from 1 to 5 are defined by the manufacturer and they can be changed only by an authorized technician.

Do not use flammable liquids during the ignition (alcool, petrol, oil, etc...).

10.3 CONTROL PANEL

PANEL ELEMENT DESCRIPTION

P1 and P2: when in set temperature mode, they are useful to increase or decrease the thermostat value from min. 6°C to max 40°C. Keeping pressed P2 key it is possible to see the fume temperature at the exhaust. Both have programming functions.

P3: it enables to enter set temperature and User and Technician parameters menu.

P4: switching on and off, alarm reset and exit from programming.

P5 and P6: increase and decrease the calorific power from 1 to 5.

Page 26 of the Cadel SQUARE user manual — PANEL ELEMENT DESCRIPTION
Pagina 26 · clicca per ingrandire
Pagina 26

PANEL ELEMENT DESCRIPTION

Chrono: active time programming.

Ignition plug: active ignition.

Auger: active.

Fume fan: active.

Exchanger fan: active.

Alarm: active.

Cadel SQUARE — PANEL ELEMENT DESCRIPTION diagram (page 26)
Fig. 39

Fig. 35 - LCD control display

LEGEND Fig. 35 page 76 1 Time 2 Power 3 State 4 Message 5 Temperature

Page 27 of the Cadel SQUARE user manual — 10.5 START UP
Pagina 27 · clicca per ingrandire
Pagina 27

10.4 USER MENU

By once pressing P3 key you can hace access to user parameter controlling. To let them slide press P5 and P6 keys. They are:

POS. REFERENCE DESCRIPTION

1 FAN ADJUST (supplementary) Module not included in this type of stove.

2 SET CLOCK Set date and time. The board is provided with a lithium battery which enables a clock autonomy of 3/5 years. See CLOCK SETTING page 79.

Press once P3: “CHRONO ENABLE” appears. Press P3 again and with P1 and P2 put in “OFF” or “ON”. For daily, week-end or weekly programming, see DAILY PROGRAMMING page 79. CAUTION: do not active if STAND-BY function is active!

3 SET CHRONO

4 SELECT LANGUAGE Press once P3 key and with P1 and P2 keys select the desired language.

It activates a function which, if the set ambient temperature has been exceeded for more then 10 minutes, start the switching off phase up. If the ambient temperature has fall at more than 2°C, the stove will restart automatically up, starting from START UP page 77. Press once P3 key and with P1 and P2 keys put in “OFF” or “ON”. CAUTION: do not activate if CHRONO function is active!

5 STAND-BY MODE

6 BUZZER MODE (audio alarm) Press once P3 key and with P1 and P2 keys put in “OFF” or “ON”.

When the stove has its first ignition, the auger is completely empty. If it should be necessary do a precharge by pressing P3 key, then P1 key for starting up and P4 key for stop.

7 INITIAL LOAD

8 STOVE STATE It shows all parameters connected to the stove state: this is a menu for the Authorized Techinician

9 TECHNICA SETTING Only for the Authorized Technician.

10 SET FLAME It enables to set the flame dipending on the draught of the chimney flue.

10.5 START UP

  • We remind you that the first ignition must be carried out by a specialized and authorixed technician who will check that all is installed in compliance with current regulations and checks the efficiency.
  • If inside the combustion chamber there are booklets, manuals, etc..., remove them.
  • Check if the door is correctly closed.
  • Check if the stove is correctly inserted in the electric socket.
  • Before switching the stove on, assure you the burning pot is clean.
  • To start the stove up, keep pressed P4 key for an instant till it will be shown “START” and “PREHEATI WAIT”: the preheating of the ingnition resistance starts. After 2 minutes about, it will be shown “PELLET LOAD, FLAME WAIT”, in this phase the auger loads the pellet and the heating of the resistance continues. When the temperature is sufficiently high (after 7-10 minutes about), the ignition is considered as happened and on the display shows “FIRE PRESENT”.
  • Completed the phase “FIRE PRESENT”, the control unit enter the “WORK” phase showing the set calorific power and ambient temperature. It is in this phase that P5 and P6 keys settle the stove power from 1 to 5. If the value of the ambient temperature exceeds the limit set on the keyboard on the temperature setting, the calorific power will be carried at the minimum showing “WORK, MODULATI”. When the ambient temperature turns back below the set temperatur, the stove turns back to the set power.
Page 28 of the Cadel SQUARE user manual — 10.10 FUME TEMPERATURE
Pagina 28 · clicca per ingrandire
Pagina 28

10.6 STOVE ADJUSTMENT

  • The stove is adjusted according to the chimney flue and used pellets datas, as per technical characteristics (see FEATURES page 98 ). If the datas do not correspond, the authorized technician can adjust the stove.
  • If the pellet is small in size and with a greater calorific power, (for example: encrusted burning pot), the pellet drop must be decreased from the menu “SET FLAME”, press P3 “PELLET TYPE”, press P3 again “PELLET LOAD” and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
  • If the chimney flue has a lower draught (for example: weak flame, sooty glass) the revolutions of the geared motor must be increased from the menu “SET FLAME”, press P5 “CHIMNEY TYPE”, press P3 “FUMEFAN CHIMNEY” and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9 (which is +30%).
  • If the chimney flue has a greater draught (for example: because of pellets fall on the burning pot) decrease the fume fan revolutions from -1 to -9.

Pay attention if the value is positive or negative..

10.7 FAILED IGNITION

If the pellets do not burn, the failed ignition will be indicated by the alarm “FAILED IGNITION”. • If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for example firelighters cubes).

After a failed ignition the burning pot must be empty from the amassed pellets, before starting the stove up again.

  • Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create dense white smoke which is harmful to health and can cause explosions on the combustion chamber. It is therefore necessary not to stand in front of the stove during ignition stage if dense white smoke is present.

If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.

10.8 POWER FAILURE

  • After a black-out lower than 5 seconds, the stove turns back to the power which was settled.
  • After a black-out of more than 5 seconds, the stove enters the “COOLING WAIT” phase. Completed this phase, it starts automatically up with the different phases (see START UP page 77 ).

10.9 TEMPERATURE SETTING

  • To modify the ambient temperature it is sufficient to press P1 and P2 keys according to the desired temperature inside the menu “SET TEMP AMBIENT”.
  • To see the set temperature, press once P1 key.

10.10 FUME TEMPERATURE

To check the fume temperature at the exhaust it is sufficient to keep pressed P2 key.

Page 29 of the Cadel SQUARE user manual — 10.14 WEEK-END PROGRAMMING
Pagina 29 · clicca per ingrandire
Pagina 29

10.11 SWITCHING OFF

To switch the stove off, keep pressed P4 key: the display shows “FINAL CLEANING”. After about 10 minutes, also the fume fan switches off (this happens always, independently if the stove is hot or cold). Then “OFF” will be shown.

If the pellets are of bad quality (if contains sizing agents, oils, varnishes, plastic remains or if it is mealy), deposits will form along pellets drop pipe during the running. When the stove is switched off, these remains could form little hot coals that rising along the pipe could reach the pellets on the hopper burning them and creating a thick and harmful smoke inside the room. Please always keep the hopper closed with its own lid. If the pipe is sooty, please clean it (see INTRODUCTION page 83).

10.12 CLOCK SETTING

  • Press P3 key and then P5 key till underlining “SET CLOCK” menu (02).
  • Press once P3 (DAY) and with P1 and P2 keys select the day of the week (Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday).
  • Press for the second time P3 key (HOURS) and with P1 and P2 keys set the hour.
  • Press for the third time P3 key (MINUTES) and with P1 and P2 keys select the minutes. Press for the fourth time P3 key (DAY) and with P1 and P2 keys select the day of the month (1,2,3...29,30,31).
  • Press for the fifth time P3 key (MONTH) and with P1 and P2 keys select the month:
  • Press for the sixth time P3 key (YEAR) and with P1 and P2 keys select the year.
  • To exit from the programme press P4 twice.

10.13 DAILY PROGRAMMING

  • It allows to enable, disable and settle the daily chronothermostat functions. Press P3 key and then P5 key till the menu “SET CHRONO”. Press once P3 key and with P5 and P6 keys select the “PROGRAM DAY”. Press once P3 till finding “CHRONO DAY”. With P1 and P2 keys put in “OFF” or “ON”. It is possible to set two working times delimited by the set times. After “CHRONO DAY”:
  • Press P5: the display shows “START 1”, with P1 and P2 keys set the ignition time value or put in “OFF”.
  • Press P5: the display shows “STOP 1”, with P1 and P2 keys set the switching off time value or put in “OFF”.
  • Press P5: the display shows “START 2”, with P1 and P2 keys set the ignition time value or put in “OFF”.
  • Press P5: the display shows “STOP 2”, with P1 and P2 keys set the switching off time value or put in “OFF”.
  • Press P4 key three times to exit from the menu.

10.14 WEEK-END PROGRAMMING

  • It allows to enable, disable and settle the chronothermostat functions during saturday and sunday. Press P3 key and then P5 key till the menu “SET CHRONO”. Press once P3 key and with P5 and P6 keys select “PROGRAM WEEK-END”. Press once P3 till finding “CHRONO WEEK-END”. With P1 and P2 keys put in “OFF” or “ON”. It is possible to set two working times delimited by the set times and valid only for saturday and sunday. After “CHRONO WEEK-END”:
  • Press P5: the display shows “START 1 WEEK-END”, with P1 and P2 keys set the ignition time value or put in “OFF”.
  • Press P5: the display shows “STOP 1 WEEK-END”, with P1 and P2 keys set the switching off time value or put in “OFF”.
  • Press P5: the display shows “START 2 WEEK-END”, with P1 and P2 keys set the ignition time value or put in “OFF”.
  • Press P5: the display shows “STOP 2 WEEK-END”, with P1 and P2 keys set the switching off time value or put in “OFF”.
  • Press P4 key three times to exit from the menu.
Page 30 of the Cadel SQUARE user manual — 10.17 PELLET SUPPLY
Pagina 30 · clicca per ingrandire
Pagina 30

10.15 WEEKLY PROGRAMMING

  • It allows to enable, disable and settle the weekly hermostat functions (saturday and sunday included). Press P3 key and then P5 key till the menu “SET CHRONO”. Press once P3 key and with P5 and P6 keys select “PROGRAM WEEK”. Press once P3 till finding “WEEKLY CHRONO”. With P1 and P2 keys put in “OFF” or “ON”. It is possible to set four working times delimited by the set times. After “WEEKLY CHRONO”: Press P5: the display shows “START PROG-1”, with P1 and P2 keys insert the ignition time value or put in “OFF”. Press P5: the display shows “STOP PROG-1”, with P1 and P2 insert the switching off value or put in “OFF”.
  • Press P5: the display shows “MONDAY PROG-1”, with P1 and P2 keys set “ON” or “OFF”.
  • Press P5: the display shows “TUESDAY PROG-1”, with P1 and P2 keys set “ON” or “OFF”.
  • Press P5: the display shows “WEDNESDA PROG-1”, with P1 and P2 keys set “ON” or “OFF””.
  • Press P5: the display shows “THURSDAY PROG-1”, with P1 and P2 keys set “ON” or “OFF”.
  • Press P5: the display shows “FRIDAY PROG-1”, with P1 and P2 keys set “ON” or “OFF”.
  • Press P5: the display shows “SATURDAY PROG-1”, with P1 and P2 keys set “ON” or “OFF””.
  • Press P5: the display shows “SUNDAY PROG-1”, with P1 and P2 keys set “ON” or “OFF”.
  • Now press P5 and repeat all the previous instructions for Prog-2, Prog-3, Prog-4.
  • To exit press three times P4.

10.16 FIRE EXTINGUISHING IN CASE OF FIRE

In case it would be necessary to extinguish the fire emitted by the stove or by the chimney flue, use a fire- extinguisher or contact the firemen. DO NOT use water to extinguish the fire inside the burning pot.

10.17 PELLET SUPPLY

Cadel SQUARE — 10.17 PELLET SUPPLY diagram (page 30)
Fig. 40
Cadel SQUARE — 10.17 PELLET SUPPLY diagram (page 30)
Fig. 41

Fig. 36 - Wrong opening of the pellets bag Fig. 37 - Right opening of the pellets bag

  • It is necessary to avoid to fill the hopper with the pellet when the stove is running.
  • Do not get the bag of pellet in contact with hot stove surfaces.
  • Do not empty the hopper with remaining fuels (unburnt pellet) from the burning pot coming from ignition waster.

The pellet hopper must always be closed with its own lid.

Page 31 of the Cadel SQUARE user manual — 11.3 ”FUME PROBE” ALARM
Pagina 31 · clicca per ingrandire
Pagina 31

10.18 REMOTE CONTROL (OPTIONAL)

The stove can be operated through a remote control. (Please install 12V N type battery)

Cadel SQUARE — 10.18 REMOTE CONTROL (OPTIONAL) diagram (page 31)
Fig. 42

Fig. 38 - Remote control

LEGEND Fig. 38 page 81 Button 1 Increase the desired temperature Button 2 Decrease the desired temperature Button 5 Decrease the power level from 1 to 5 Button 6 Increase the power level from 1 to 5 Buttons 1

and 6 Pressed together enable to turn the stove on and off

11 SAFETY SYSTEM

11.1 INTRODUCTION

Safety devices are used to prevent and avoid the risk of damages to people, animales and objects. It is forbidden to execute repearing by no authorized personnel otherwise the warranty and the manufacturer liability fall.

Before of every intervention leave the fire completely extinguish till the cooling and always disconnect the plug from the electric socket.

11.2 ”BLACK OUT” ALARM

  • “ACTIVE ALARM” “AL 1 - BLACK OUT”: current breaking during ignition.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”:
  • Clean the burning pot and start the stove up again with P4 key.

11.3 ”FUME PROBE” ALARM

To the exhaust is connected a probe which contantly controls the temperature during working time.

Page 32 of the Cadel SQUARE user manual — 11.9 ”FAILURE DEPRESS” ALARM
Pagina 32 · clicca per ingrandire
Pagina 32
  • “ACTIVE ALARM” “AL 2 - FUME PROBE”: the probe is damaged or disconnected.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
  • Check the type of glitch as ALARMS page 89 .
  • Clean the burning pot and start the stove up again with P4 key.

11.4 ”HOT FUME” ALARM

  • If the fume probe registers a temperature at the exhaust higher then 180°C, the display shows “HOT FUME”. Then the combustible (pellet) drop will be decreased at phase 1. This function has the aim to bring the values within preset values. If for any reason the temperature would not decreas but increase, at 215°C the display shows “ACTIVE ALARM” “AL 3 - HOT FUME” and the stove start the switching off phase up.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
  • Check the type of glitch as ALARMS page 89 .
  • Clean the burning pot and start the stove up again with P4 key.

11.5 ”FAN FAILURE” ALARM

  • “ACTIVE ALARM” “AL 4 - FAN FAILURE”: the fume fan is out of order.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
  • Check the type of glitch as ALARMS page 89 .
  • Clean the burning pot and start the stove up again with P4 key.

11.6 ”FAILED IGNITION” ALARM

  • “ACTIVE ALARM” “AL 5 - FAILED IGNITION”: the temperatureis not sufficient for ignition.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
  • Check the type of glitch as ALARMS page 89 .
  • Clean the burning pot and start the stove up again with P4 key.

11.7 ”NO PELLET” ALARM

  • If the fume probe registers a temperature at the exhaust lower than the minimum threshold and the display shows “ACTIVE ALARM” “AL 6 - NO PELLET”.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
  • Full the hopper.
  • Clean the burning pot and start the stove up again with P4 key.

11.8 ”THERMAL SAFETY” ALARM

  • In the hopper is installed a automatic thermostat which activates if the temperature excursion exceeds the allowed limits, so avoiding the possibility that the pellet inside the hopper could burn because of overheating. “ACTIVE ALARM” “AL 7 - THERMAL SAFETY”: the thermostat stops the power supply to the auger.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”.
  • Check the type of glitch as ALARMS page 89 .
  • Clean the burning pot and start the stove up again with P4 key.

11.9 ”FAILURE DEPRESS” ALARM

  • To the boiler is connected a pressostat which control the depression and in some stove models on the fire door id installed a microswitch which registers the opening. “ACTIVE ALARM” “AL 8 - FAILURE DEPRESS”: the pressostat and/or fire door which is not correctly closed stops the power supply to the auger.
  • Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”.
  • Check the type of glitch as ALARMS page 89 .
  • Clean the burning pot and start the stove up again with P4 key.
Page 33 of the Cadel SQUARE user manual — 12.2 BURNING POT AND ASH TRAY CLEANING
Pagina 33 · clicca per ingrandire
Pagina 33

12 MAINTEINANCE

12.1 INTRODUCTION

  • For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
  • Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an authorized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance company.
  • If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chimney flue and chimney pot cleaned at least once a year.
  • It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical elements checked at least once a year.

All these operations must be planned in time with your Autorized Technical Assistance Service.

  • After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
  • If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked more frequently.
  • In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.

Before any movement let the fire inside the combustion chamber extinguish till the total cooling and always disconnect the plug from the socket.

12.2 BURNING POT AND ASH TRAY CLEANING

The burning pot and ash tray cleaning must be executed at least every 2 days. • Open the door.

Cadel SQUARE — 12.2 BURNING POT AND ASH TRAY CLEANING diagram (page 33)
Fig. 43
Cadel SQUARE — 12.2 BURNING POT AND ASH TRAY CLEANING diagram (page 33)
Fig. 44
Cadel SQUARE — 12.2 BURNING POT AND ASH TRAY CLEANING diagram (page 33)
Fig. 45

Fig. 39 - Burning pot extraction Fig. 40 - Ash tray extraction Fig. 41 - Burning pot cleaning

  • Extract the burning pot (see Fig. 39 page 83 ) from its seat and empty it from the ash.
  • Extract the ash tray (see Fig. 40 page 83 ) and empty it from the ash.
  • If necessary clean with a pointed object the holes obstructed by encrustations (see Fig. 41 page 83 ).
Page 34 of the Cadel SQUARE user manual — 12.3 HOPPER AND AUGER CLEANING
Pagina 34 · clicca per ingrandire
Pagina 34
Cadel SQUARE — 12 MAINTEINANCE diagram (page 34)
Fig. 46
Cadel SQUARE — 12 MAINTEINANCE diagram (page 34)
Fig. 47
Cadel SQUARE — 12 MAINTEINANCE diagram (page 34)
Fig. 48

Fig. 42 - Burning pot box cleaning Fig. 43 - Ash tray box cleaning Fig. 44 - Cleaning with a brush

  • Clean and drain away the burning pot box and ash tray box from ash which has accumulated in its inner (see Fig. 42 page 84 and Fig. 43 page 84 ).
  • Clean also the hole for pellet drop with a brush (see Fig. 44 page 84 ).
  • The ash remains must be poured in a metal container with a sealed lid and this container must never get in touch with combustible materials (for example put on a wooden floor), as the inner ash keeps the embers firing for a long time.
  • Only when the embers are off the ash coul be poured in the organic waste.
  • Pay attention if the flame becomes red colured, if it is weak or if black smoke creates in the inner: in this case the burning pot is encrusted and needs to be cleaned. If it is broken, it must be replaced.

12.3 HOPPER AND AUGER CLEANING

Per each pellets supply, check the probable presence of meal, sawdust and other remanins on the hopper bottom. If present, they must be removed with the aid of a vacuum cleaner (see Fig. 45 page 84).

Cadel SQUARE — 12.3 HOPPER AND AUGER CLEANING diagram (page 34)
Fig. 49

Fig. 45 - Hopper and auger cleaning

The hand rejector grid must not ever be removed fron its housing. Clean the hopper bottom and the visible part of the auger exclusively as shown in the picture (see Fig. 45 page 84).

Page 35 of the Cadel SQUARE user manual — 12.5 FUME CONDUIT CLEANING
Pagina 35 · clicca per ingrandire
Pagina 35

If the auger is blocked by a foreign object (for example: nails), and if it needs to be cleaned, DO NOT remove the hand rejector and DO NOT touch the auger. Please contact the stove manufacturer or the Technical Assistance service of the stove manufacturer.

The hand rejector can be removed exclusively by an authorized technician.

12.4 FUME CHAMBER CLEANING

Every 4/8 weeks the fume chamber cleaning must be executed. For CLOE model: remove top panel and then right panel. For SQUARE model: loosen the 2 screws that lock front right panel and remove it.

Cadel SQUARE — 12.4 FUME CHAMBER CLEANING diagram (page 35)
Fig. 50
Cadel SQUARE — 12.4 FUME CHAMBER CLEANING diagram (page 35)
Fig. 51

Fig. 46 - Fume chamber Fig. 47 - Fume chamber cleaning

  • Unscrew the 2 fume chamber closing zincate panel screw (see Fig. 46 page 85 ).
  • Clean with a vacuum cleaner the ash which has accumulated on the inner (see Fig. 47 page 85 ).
  • After the cleaning the opposite operation is to repeat checking the gasket efficiency and integrity: if necessary provide for its replacement by an Authorized Technician.

12.5 FUME CONDUIT CLEANING

The exhaust system must be cleaned every month.

Cadel SQUARE — 12.5 FUME CONDUIT CLEANING diagram (page 35)
Fig. 52

Fig. 48 - Fume conduit cleaning

Page 36 of the Cadel SQUARE user manual — 12.7 ROOM FAN CLEANING
Pagina 36 · clicca per ingrandire
Pagina 36
  • Remove the inspection lid of the T-union (see Fig. 48 page 85 ).
  • Extract the ash which has accumulated in the inner.
  • After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary replace it.

Is it important to hermetically seal the cap to avoid harmful fumes escaping into the room.

12.6 FUME FAN CLEANING

Clean every the year the fume fan from ash or dust which can cause a blade unbalance and a greater noise.

As this operation is so delicate it must therefore be executed by an Authorized Technician.

Cadel SQUARE — 12.6 FUME FAN CLEANING diagram (page 36)
Fig. 53
Cadel SQUARE — 12.6 FUME FAN CLEANING diagram (page 36)
Fig. 54
Cadel SQUARE — 12.6 FUME FAN CLEANING diagram (page 36)
Fig. 55

Fig. 49 - Fume fan cleaning: phase1 Fig. 50 - Phase 2 Fig. 51 - Phase 3

  • Follow the process as describer in Fig. 49 page 86 , Fig. 50 page 86 and Fig. 51 page 86 .

12.7 ROOM FAN CLEANING

Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.

As this operation is so delicate it must therefore be executed by an Authorized Technician.

Cadel SQUARE — 12.7 ROOM FAN CLEANING diagram (page 36)
Fig. 56

Fig. 52 - Room fan cleaning

Page 37 of the Cadel SQUARE user manual — 12.8 FUME PASSAGES CLEANING
Pagina 37 · clicca per ingrandire
Pagina 37
  • Remove the lower panel and clean with a vacuum cleaner the ash and the dust which has accumulated on the inner (see Fig. 52 page 86 ).

12.8 FUME PASSAGES CLEANING

Clean the fume passages every year.

Cadel SQUARE — 12.8 FUME PASSAGES CLEANING diagram (page 37)
Fig. 57
Cadel SQUARE — 12.8 FUME PASSAGES CLEANING diagram (page 37)
Fig. 58

Fig. 53 - Remove upper grid Fig. 54 - Remove top cover

  • Remove upper grid (see Fig. 53 page 87 ).
  • Loosen the screws of top cover (see Fig. 54 page 87 ).
Cadel SQUARE — 12.8 FUME PASSAGES CLEANING diagram (page 37)
Fig. 59
Cadel SQUARE — 12.8 FUME PASSAGES CLEANING diagram (page 37)
Fig. 60

Fig. 55 - Fume passages cleaning Fig. 56 - Silicon laying

  • Clean the fume passages with the aid of a brush (see Fig. 55 page 87 ).
  • Lay the silicon round the hole (see Fig. 56 page 87 ) and screw again the lids.
  • Reassemble all.
Page 38 of the Cadel SQUARE user manual — 12.14 GLASS CLEANING
Pagina 38 · clicca per ingrandire
Pagina 38

12.9 FUME PIPES ANNUAL CLEANING

Clean once a week from soot with brushes. The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This operation must be executed at least once a year.

12.10 GENERAL CLEANING

For cleaning external and inner parts of the stove do not use steel wools, muriatic acid or other corrosive and abrasive materials.

12.11 CLEANING OF PAINTED METAL PANELS

To clean painted metal panels use a soft cloth. Do not use degreasant agents like alcool, diluents, acetone, gasoline because these could irremediably damage the varnish.

12.12 CLEANING OF CERAMIC AND STONE PANELS

Some stove models has an external lining made up of ceramic or stone. These pieces are handmade therefore they could inevitably present crazings, seedinesses, shadings. To clean ceramic or stone panels use a soft and dry cloth. If using any cleaners this will seep through the crazings putting them in evidence.

12.13 GASKET REPLACEMENT

In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in order to guarantee the good running of the stove.

Use exclusively original spare parts.

12.14 GLASS CLEANING

The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks. The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions.

You should clean the fire door glass every day!

Page 39 of the Cadel SQUARE user manual — AL 4 - FAN FAILURE
Pagina 39 · clicca per ingrandire
Pagina 39

13 IN CASE OF ANOMALY

13.1 ALARMS

Before of every intervention of the Authorized Technician, the same Technician has the duty to check that the parameters of the mother board correspond with those of the table you own.

In case of doubts regarding the use of the stove, please call ALWAYS the Authorized Technician in order to avoid irreparable damages!

ALARM CAUSE SOLUTION INTERVENTION

AL 1 - BLACK OUT

Power cut during ignition phase.

Clean the burning pot and switch the stove on again.

Disconnected fume temperature probe Have the stove checked.

AL 2 - FUME PROBE

Faulty fume temperature probe Replace the fume probe.

Faulty fume probe Replace the fume probe.

Faulty mother board Replace the electronic board.

AL 3 - HOT FUME

The exchanger fan does not work Replace the ambient fan.

Too high pellet drop value Adjust the pellet loading.

Faulty protection fuse of the fume fan Replace the fuse (1,25A).

AL 4 - FAN FAILURE

The pellets can burn also thanks to the chimney flue depression and without the aid of the fume fan. Have the fume fan replaced immediately. It can be noxious to health to let the stove running without fume fan.

Faulty fume fan

Page 40 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Pagina 40 · clicca per ingrandire
Pagina 40
Cadel SQUARE — 12 MAINTEINANCE diagram (page 40)
Fig. 61

The burning pot has not been cleaned Clean the burning pot.

Clean the burning pot and switch the stove on again.

Too sever external temperature Start the stove up again.

Humid pellet The pellets must be stored in a dry place. Please check it.

AL 6 - NO PELLET Empty hopper Full the hopper.

Boiler overheating Let the stove cooling. (If the problem persits please call an Authorized Technician).

The ambient exchanger fan does not work Replace the ambient fan.

The lack of tension during the running implies the overheating of the boiler and the intervention of the automatic thermostat. Let the stove cooling and start the stove up again.

Page 41 of the Cadel SQUARE user manual — AL 8 - FAILURE DEPRESS
Pagina 41 · clicca per ingrandire
Pagina 41

ALARM CAUSE SOLUTION INTERVENTION

The exhaust chimney is partially or totally obstructed. Call en expert stove-repairer who executes a check from the exhaust up to the chimney pot.

The pellet can burn also thanks to the chimney flue depression without the aid of the fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fan.

Fume fan out of order

Obstructed connecting nozzle Clean the connecting nozzle.

Faulty pressostat Replace the pressostat.

AL 8 - FAILURE DEPRESS

Faulty electronic board Replace the mother board.

Contact an expert stove repairer and check that the exhaust chimney is in compliance with regulations: see CHIMNEY FLUE page 56.

In case of strong wind there can be a negative pressure to the chimney. Check and switch the stove on again.

The fire door is not correctly closed

Close the fire door correctly and check if the gaskets are broken.

Fire door microswitch faulty or out of order Replace the fire door microswitch.

Obstructed exhaust · Extreme chimney lenght · Advers whether conditions

Page 42 of the Cadel SQUARE user manual — PROBLEM CAUSE SOLUTION INTERVENTION
Pagina 42 · clicca per ingrandire
Pagina 42

13.2 PROBLEM SOLVING

Before of every Authorized Technician intervention, the same Technician has the duty to check if the parameters of the mother board correspond to those of the table you own.

In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to avoi irreparable damages!

PROBLEM CAUSE SOLUTION INTERVENTION

The stove is without power supply

Check if the plug is connected.

Burned board protection fuse Replace the protection fuse in the board (4A-250V)

Burned protection fuse in the electric socket

Replace the protection fuses in the electric socket (3.15A-250V).

The control display does not switch on

Faulty control display Replace the control display.

Faulty flat cable Replace the flat cable.

Faulty electronic board Replace the mother board.

Empty hopper Full the hopper.

Auger blocked by a foreign object (for example nails)

Clean the auger.

Pellets do not reach the combustion chamber

The auger geared motor is out of order

Replace the geared motor.

Check if on the display there is an “ACTIVE ALARM”

Have the stove checked.

Page 43 of the Cadel SQUARE user manual — PROBLEM CAUSE SOLUTION INTERVENTION
Pagina 43 · clicca per ingrandire
Pagina 43

PROBLEM CAUSE SOLUTION INTERVENTION

Empty hopper Full the hopper.

Auger blocked by a foreign object (for example nails)

Clean the auger.

The fire extinguish and the stove stops

Bad quality pellets Try other types of pellets.

Pellet drop value too low “phase 1” Adjust the pellet loading.

Check if on the display there is an “ACTIVE ALARM”

Have the stove checked.

Stove running and display showing “BURN POT CLEANING”

Automatica burning pot cleaning

The stove is at minimum, fume fan at maximum. NO PROBLEM!

Check as following: probable obstructions of the combustible air inlet from the back or from the bottom of the stove; burning pot obstructed holes with too ash remains. Have the fan blades and auger cleaned.

Not sufficient combustion air

The exhaust chimney is partially or totally obsturcted. Contact an expert stove-repairer who checks the stove from the exhaust up to the chimney pot. Provide immediately for stove cleaning.

Flames are weak and orange coloured, pellets do not burn properly and the glass blackens

Obstructed stove Provide immediately at the inner cleaning of the stove.

The pellets can burn also thanks to chimney flue depression without the aid of the fume fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fume fan.

The fume fan is out of order

Faulty fume temperature probe

The exchanger fan continues to turn even though the stove has just cooled

Replace the fume probe.

Faulty mother board Replace the mother board.

Faulty or out of order door gaskets

Replace the gaskets.

Ash remains along the stove

Contact an expert stove-repairer who will immediately provide for sealing the junctions with high-temperature silicone and/or for replacing pipes with those in compliance to current regulations. A not sealed fume channelisation can be noxious to health.

Not sealed fume pipes

Obstructed exhaust

Page 44 of the Cadel SQUARE user manual — 14.2 REPAIR INFORMATION
Pagina 44 · clicca per ingrandire
Pagina 44

PROBLEM CAUSE SOLUTION INTERVENTION

The stove runs at minimum. NO PROBLEM!

Stove running and display showing “WORK, MODULATI”

Reached fume outlet limit temperature

The stove runs at minimum. NO PROBLEM!

14 TECHNICAL DATAS

14.1 WIRING SCHEME

Cadel SQUARE — 14.1 WIRING SCHEME diagram (page 44)
Fig. 62

Fig. 57 - Wiring scheme

14.2 REPAIR INFORMATION

Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical components. • For fuse replacement in the electric socket which lies on the back of the stove, extract the fuses to change with the aid of a screwdriver in the shutter (see Fig. 58 page 95).

Reached ambient temperature

Page 45 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Pagina 45 · clicca per ingrandire
Pagina 45
Cadel SQUARE — 12 MAINTEINANCE diagram (page 45)
Fig. 63

Fig. 58 - Shutter with the fuse to remove

  • Proceed as follows (see Fig. 59 page 96 ):
  • Remove all panels.
  • After these operations you can have access at the following components: geared motor (3), ignition plug (5), ambient fan (8), fume fan (7), ambient probe (10), fume probe (9), thermostat (6), electronic board (1), pressostat (4). For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor (3) and to extract it, unscrew the two screws lying under the geared motor of the auger, remove the hand rejector inside the hopper and then unscrew the inner bolt of the auger. To assembly proceed at the contrary.
Page 46 of the Cadel SQUARE user manual — 14.3 SPARE PARTS
Pagina 46 · clicca per ingrandire
Pagina 46

14.3 SPARE PARTS

Cadel SQUARE — 14.3 SPARE PARTS diagram (page 46)
Fig. 64

Fig. 59 - Spare parts

Page 47 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Pagina 47 · clicca per ingrandire
Pagina 47
Cadel SQUARE — 12 MAINTEINANCE diagram (page 47)
Fig. 65

15 CLO5210 CERAMIC GLASS 217x217x4 (SQUARE AND CALDARA MODELS)

21 CLO5412 COLOURED METAL HORIZONTAL TRAPEZIUM PANEL 810x198 (CLOE MODEL)

22 CLO5413 COLOURED METAL VERTICAL TRAPEZIUM PANEL 760x198 (CLOE MODEL)

23 CLO5446 GLASS HORIZONTAL TRAPEZIUM PANEL 815,6x200 (CLOE MODEL)

24 CLO5447 GLASS VERTICAL TRAPEZIUM PANEL 761x200 (CLOE MODEL)

25 CLO5444 SERPENTINE HORIZONTAL TRAPEZIUM PANEL 815,6x200 (CLOE MODEL)

26 CLO5445 SERPENTINE VERTICAL TRAPEZIUM PANEL 761x200 (CLOE MODEL)

The undermentioned information are indicatives and no binding. The manufacturer reserves the ability of bringing modifications of every type with the aim to improve performances.

Page 48 of the Cadel SQUARE user manual — STOVE WITH SEALED CHAMBER YES YES
Pagina 48 · clicca per ingrandire
Pagina 48

14.4 FEATURES

DESCRIPTION CLOE 6,5 kW SQUARE 6,5 kW

WIDTH 82 cm 82 cm

DEPTH 28,5 cm 27 cm

HEIGHT with pedestal 91,5 cm 92 cm

WEIGHT with pedestal 92-98-107 kg 92-98 kg

INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,3 kW 2,8 - 7,3 kW

NOMINAL THERMIC POWER (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW

EFICIENCY (Min/Max) 88 - 89,5 % 88 - 89,5 %

FUME TEMPERATURE (Min/Max) 129 - 193 °C 129 - 193 °C

FUME MAXIMUM LOADING CAPACITY (Min/Max) 3,4 - 4,4 g/s 3,4 - 4,4 g/s

CO EMISSIONS (13% O2) (Min/Max) 0,049 - 0,010 % 0,049 - 0,010 %

OGC EMISSIONS (13% O2) 0,4 mg/Nm3 0,4 mg/Nm3

NOX EMISSIONS (13% O2) 118 mg/Nm3 118 mg/Nm3

CO2 EMISSIONS (Min/Max) 5,3 - 10,5 % 5,3 - 10,5 %

Medium CO CONTENTS at 13% O2 (Min/Max) 610 - 123 mg/Nm3 610 - 123 mg/Nm3

Medium POWDER CONTENTS at 13% O2 (Max) 16 mg/Nm3 16 mg/Nm3

CHIMNEY DEPRESSION (Min/Max) 11 - 12 Pa 11 - 12 Pa

MINIMUM SAFETY DISTANCE from flammable materials 30 cm 30 cm

ON SHARED CHIMNEY FLUE NO NO

FUME OUTLET DIAMETER Ø80 mm Ø80 mm

COMBUSTIBLE Pellet Ø6-7 mm Pellet Ø6-7 mm

PELLETS HEATING VALUE 5 kWh/kg 5 kWh/kg

PELLETS HUMIDITY ≤ 10% ≤ 10%

HEATING VOLUME 18/20°C Coeff. 0,045 kW (Min/ Max) 60 - 156 m3 60 - 156 m3

HOURLY CONSUMPTION (Min/Max) 0,6 - 1,5 kg/h 0,6 - 1,5 kg/h

HOPPER CAPACITY 8 kg 8 kg

RANGE (Min/Max) 13,3 - 5,3 h 13,3 - 5,3 h

SUPPLY 230 V - 50 Hz 230 V - 50 Hz

POWER INPUT (Max) 350 W 350 W

INGNITER RESISTANCE POWER INPUT 300 W 300 W

MINIMUM EXTERNAL AIR INLET (last effective area) 80 cm2 80 cm2

STOVE WITH SEALED CHAMBER YES YES

EXTERNAL AIR INLET FOR SEALED CHAMBER Ø60 mm Ø60 mm

Page 49 of the Cadel SQUARE user manual — 14.5 DECLARATION OF CONFORMITY
Pagina 49 · clicca per ingrandire
Pagina 49

14.5 DECLARATION OF CONFORMITY

Fig. 60 - Declaration of Conformity

Page 50 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Pagina 50 · clicca per ingrandire
Pagina 50
Page 50 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Page 51 of the Cadel SQUARE user manual — POÊLE A CHAMBRE ÉTANCHE OUI OUI
Pagina 51 · clicca per ingrandire
Pagina 51

14.4 CARACTÉRISTIQUES

DESCRIPTION CLOE 6,5 kW SQUARE 6,5 kW

LARGEUR 82 cm 82 cm

PROFONDEUR 28,5 cm 27 cm

HAUTEUR avec piédestal 91,5 cm 92 cm

FR

POIDS avec piédestal 92-98-107 kg 92-98 kg

PUISSANCE THERMIQUE INTRODUITE (Min/Max) 2,8 - 7,3 kW 2,8 - 7,3 kW

PUISSANCE THERMIQUE NOMINALE (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW

EFFICIENCE (Min/Max) 88 - 89,5 % 88 - 89,5 %

TEMPÉRATURE FUMÉES (Min/Max) 129 - 193 °C 129 - 193 °C

DÉBIT MAXIMUM DES FUMÉES 3,4 - 4,4 g/s 3,4 - 4,4 g/s

EMISSIONS CO (13% O2) (Min/Max) 0,049 - 0,010 % 0,049 - 0,010 %

EMISSIONS OGC (13% O2) 0,4 mg/Nm3 0,4 mg/Nm3

EMISSIONS NOX (13% O2) 118 mg/Nm3 118 mg/Nm3

ÉMISSIONS CO2 (Min/Max) 5,3 - 10,5 % 5,3 - 10,5 %

TENEUR moyenne de CO à 13% O2 (Min/Max) 610 - 123 mg/Nm3 610 - 123 mg/Nm3

TENEUR moyenne de POUSSIÈRES à 13% O2 (Max) 16 mg/Nm3 16 mg/Nm3

DÉPRESSION CHEMINÉE (Min/Max) 11 - 12 Pa 11 - 12 Pa

DISTANCE MINIMAL de sécurité du matériel inflammable 30 cm 30 cm

SUR CONDUIT DES FUMÉES PARTAGE NO NO

DIAMÈTRE ÉVACUATION FUMÉES Ø80 mm Ø80 mm

COMBUSTIBLE Pellet Ø6-7 mm Pellet Ø6-7 mm

POUVOIR CALORIFIQUE PELLETS 5 kWh/kg 5 kWh/kg

HUMIDITÉ PELLETS ≤ 10% ≤ 10%

VOLUME RECHAUFFABLE 18/20°C Coefficient 0,045 Kw (Min/Max) 60 - 156 m3 60 - 156 m3

CONSOMMATION HORAIRE (Min/Max) 0,6 - 1,5 kg/h 0,6 - 1,5 kg/h

CAPACITÉ RÉSERVOIR 8 kg 8 kg

AUTONOMIE (Min/Max) 13,3 - 5,3 h 13,3 - 5,3 h

ALIMENTATION 230 V - 50 Hz 230 V - 50 Hz

PUISSANCE ABSORBÉE (Max) 350 W 350 W

PUISSANCE ABSORBÉE RÉSISTANCE ALLUMEUR 300 W 300 W

MINIMUM PRISE D’AIR EXTÉRIEUR (derniere surface nette) 80 cm2 80 cm2

POÊLE A CHAMBRE ÉTANCHE OUI OUI

PRISE D’AIR EXTÉRIEUR POUR CHAMBRE ÉTANCHE Ø60 mm Ø60 mm

Page 52 of the Cadel SQUARE user manual — 14.5 DÉCLARATION DE CONFORMITÉ
Pagina 52 · clicca per ingrandire
Pagina 52

14.5 DÉCLARATION DE CONFORMITÉ

FR

Fig. 58 - Déclaration de Conformité

Page 53 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Pagina 53 · clicca per ingrandire
Pagina 53
Page 53 of the Cadel SQUARE user manual — 12 MAINTEINANCE
Fonti

Riferimenti e link

Pagine di riferimento in questo manuale: produttore, supporto e download.

Codici sul display

Codici di errore

Il significato dei codici di errore mostrati sul display e come cancellarli.

CodiceSignificatoRisolvi
AL5FAILED p.40
Riparazione

Risoluzione dei problemi

Problemi comuni, cause probabili e soluzioni.

ProblemaPossibile causaSoluzione
The control display does not switch onThe stove is without power supplyCheck if the plug is connected. p.42
The control display does not switch onBurned board protection fuseReplace the protection fuse in the board (4A-250V) p.42
The control display does not switch onBurned protection fuse in the electric socketReplace the protection fuses in the electric socket (3.15A-250V). p.42
The control display does not switch onFaulty control displayReplace the control display. p.42
The control display does not switch onFaulty flat cableReplace the flat cable. p.42
The control display does not switch onFaulty electronic boardReplace the mother board. p.42
Pellets do not reach the combustion chamberEmpty hopperFull the hopper. p.42
Pellets do not reach the combustion chamberAuger blocked by a foreign object (for example nails)Clean the auger. p.42
Pellets do not reach the combustion chamberThe auger geared motor is out of orderReplace the geared motor. p.42
Pellets do not reach the combustion chamberCheck if on the display there is an “ACTIVE ALARM”Have the stove checked. p.42
The fire extinguish and the stove stopsEmpty hopperFull the hopper. p.43
The fire extinguish and the stove stopsAuger blocked by a foreign object (for example nails)Clean the auger. p.43
The fire extinguish and the stove stopsBad quality pelletsTry other types of pellets. p.43
The fire extinguish and the stove stopsPellet drop value too low “phase 1”Adjust the pellet loading. p.43
The fire extinguish and the stove stopsCheck if on the display there is an “ACTIVE ALARM”Have the stove checked. p.43
Stove running and display showing “BURN POT CLEANING”Automatica burning pot cleaningThe stove is at minimum, fume fan at maximum. NO PROBLEM! p.43
Flames are weak and orange coloured, pellets do not burn properly and the glass blackensNot sufficient combustion airCheck as following: probable obstructions of the combustible air inlet from the back or from the bottom of the stove; burning pot obstructed holes with too ash remains. Have the fan blades and auger cleaned. p.43
Flames are weak and orange coloured, pellets do not burn properly and the glass blackensObstructed exhaustThe exhaust chimney is partially or totally obsturcted. Contact an expert stove-repairer who checks the stove from the exhaust up to the chimney pot. Provide immediately for stove cleaning. p.43
Flames are weak and orange coloured, pellets do not burn properly and the glass blackensObstructed stoveProvide immediately at the inner cleaning of the stove. p.43
Flames are weak and orange coloured, pellets do not burn properly and the glass blackensThe fume fan is out of orderThe pellets can burn also thanks to chimney flue depression without the aid of the fume fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fume fan. p.43
The exchanger fan continues to turn even though the stove has just cooledFaulty fume temperature probeReplace the fume probe. p.43
The exchanger fan continues to turn even though the stove has just cooledFaulty mother boardReplace the mother board. p.43
Ash remains along the stoveFaulty or out of order door gasketsReplace the gaskets. p.43
Ash remains along the stoveNot sealed fume pipesContact an expert stove-repairer who will immediately provide for sealing the junctions with high-temperature silicone and/or for replacing pipes with those in compliance to current regulations. A not sealed fume channelisation can be noxious to health. p.43
Stove running and display showing “WORK, MODULATI”Reached ambient temperatureThe stove runs at minimum. NO PROBLEM! p.44
Stove running and display showing “WORK, MODULATI”Reached fume outlet limit temperatureThe stove runs at minimum. NO PROBLEM! p.44

Fai una domanda su Cadel SQUARE

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Cadel SQUARE

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Cadel SQUARE manuale in PDF

354 pagine·4.6 MB·Riscaldatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…