DESCRIZIONE CLOE 6,5 kW SQUARE 6,5 kW
LARGHEZZA 82 cm 82 cm
PROFONDITÁ 28,5 cm 27 cm
ALTEZZA con piedistallo 91,5 cm 92 cm
PESO con piedistallo 92-98-107 kg 92-98 kg
POTENZA TERMICA INTRODOTTA (Min/Max) 2,8 - 7,3 kW 2,8 - 7,3 kW
POTENZA TERMICA NOMINALE (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW
EFFICIENZA (Min/Max) 88 - 89,5 % 88 - 89,5 %
TEMPERATURA FUMI (Min/Max) 129 - 193 °C 129 - 193 °C
PORTATA MASSIMA DEI FUMI (Min/Max) 3,4 - 4,4 g/s 3,4 - 4,4 g/s
EMISSIONI CO (13% O2) (Min/Max) 0,049 - 0,010 % 0,049 - 0,010 %
EMISSIONI OGC (13% O2) 0,4 mg/Nm3 0,4 mg/Nm3
EMISSIONI NOX (13% O2) 118 mg/Nm3 118 mg/Nm3
EMISSIONI CO2 (Min/Max) 5,3 - 10,5 % 5,3 - 10,5 %
CONTENUTO medio di CO al 13% O2 (Min/Max) 610 - 123 mg/Nm3 610 - 123 mg/Nm3
CONTENUTO medio di POLVERI al 13% O2 (Max) 16 mg/Nm3 16 mg/Nm3
DEPRESSIONE CAMINO (Min/Max) 11 - 12 Pa 11 - 12 Pa
DISTANZA MINIMA di sicurezza da materiali infiammabili 30 cm 30 cm
DIAMETRO SCARICO FUMI Ø80 mm Ø80 mm
COMBUSTIBILE Pellet Ø6-7 mm Pellet Ø6-7 mm
POTERE CALORIFICO PELLETS 5 kWh/kg 5 kWh/kg
VOLUME RISCALDABILE 18/20°C Coeff. 0,045 kW (Min/Max) 60 - 156 m3 60 - 156 m3
CONSUMO ORARIO (Min/Max) 0,6 - 1,5 kg/h 0,6 - 1,5 kg/h
CAPACITÀ SERBATOIO 8 kg 8 kg
AUTONOMIA (Min/Max) 13,3 - 5,3 h 13,3 - 5,3 h
ALIMENTAZIONE 230 V - 50 Hz 230 V - 50 Hz
POTENZA ASSORBITA (Max) 350 W 350 W
PRESA D’ARIA ESTERNA MINIMA (sezione utile ultima) 80 cm2 80 cm2
PRESA D’ARIA ESTERNA PER CAMERA STAGNA Ø60 mm Ø60 mm

IT

Fig. 60 - Dichiarazione di Conformità





AUTHORISED TECHNICIAN (ONLY to interpret or the Stove-manufacturer or the Authorized Technician of
Technical Assistance Service approved by the Stove-manufacturer)




In Italy biomass system installation below 35 kW must comply with MD 37/08. Every qualified installer who own these requirements, has to issue the certificate of conformity for the installed system (“system” means: stove + chimney + air inlet).
Fig. 1 - Disposal
This symbol on the product means that used electric and electronic products must not be mixed with domestic waste. For a proper disposal, recovery and/or recycling, please take this product to an authorized waste collection points, where they will be accepted for free. For further instructions, please contact your local authority or your nearest waste collection point. In case of wrong disposal of this waste material there could be applied penalties as provided by national laws.
(European directive 2002/96/CE)

Packaging are not toys and could cause suffocation or strangulation and other health hazards! People (childreen included) with reduced mobility, psycological deseases or without experience and knowledge must be kept away from packaging. The stove is not a toy, please see ATTENTION page 74.
This chapter about the Chimney Flue has been drawn up in cooperation with Assocosma (www.assocosma. org) and is based on European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443 - UNI 10683:2012). It provides instructions for a good and correct execution of the chimney flue but it does not absolutely replace the current standards which the qualified manufacturer/installer should comply with.
Please check with your local authorities if exists any restrictive regulation which regards the combustible air inlet, the fumes exhaust system, the chimney flue and the chimney pot.
The company declines any responsibility regarding the bad running of the stove if it is due to the use of a no correctly dimensioned chimney flue which does not respect current regulations.


Fig. 2 - Chimney Flues
LEGEND Fig. 2 page 57 1 Chimney flue with insulated stainless-steel pipes 2 Chimney flue on the existing chimney 3 Inspection plug 4 Inspection door 5 ≥ 3,5 mt
It is forbidden to connect more pellet stoves or any other heating appliance to the same chimney flue.


Fig. 3 - Inclined roof
LEGEND Fig. 3 page 58 1 Height over the ridge of the roof = 0,5 mt 2 Roof inclination ≥ 10° 3 90° 4 Measured distance at 90° from the roof surface = 1,3 mt
It must be insulated to avoid condensation and to reduce fume cooling effects.


Fig. 4 - Example of label
The depression (draught) of a chimney flue depends also on its height. Check the depression with the values provided at FEATURES page 98. Minimum height 3,5 meters.

Fig. 5 - Anti-wind chimney pots


Fig. 6 - Chimney components
LEGEND Fig. 6 page 60 1 Chimney pot 2 Fume outlet 3 Chimney flue 4 Termal insulation 5 External wall 6 Chimney union 7 Fume pipe 8 Heat generator 9 Inspection door 10 T-union with inspection plug



Fig. 7 - Direct air inflow Fig. 8 - Indirect air inflow
LEGEND Fig. 7 page 61|Fig. 8 page 61 1 Room to ventilate 2 Adjacent room 3 External air inlet 4 Cleft under the door


Fig. 9 - Air inlet for sealed-chamber installation
LEGEND Fig. 9 page 62 1 ≥ 1,5 mt 2 ≥ 0,3 mt 3-3 Sectional view 4 Shield grid 5 Curve inlet to turn downwards
Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by specialized personnel or companies as provided by UNI 10683:2012. • The connection between the appliance and the chimney flue should be short in order to favor the

SYSTEM TYPE Ø80 mm PIPE Ø100 mm PIPE
Minimum vertical length 1,5 mt 2 mt
Maximum length (with 1 union) 6,5 mt 10 mt
Maximum length (with 3 unions) 4,5 mt 8 mt
Maximum number of unions 3 3
Level section (minimum inclination 3%) 2 mt 2 mt
Installation at a height above 1200 m a.s.l. NO Obligatory

Fig. 10 - Example 1

LEGEND Fig. 10 page 63 1 Insulating material 2 Reduction from Ø100 to Ø80 mm 3 Inspection plug 4 Minimum safety distance = 0,5 mt

Fig. 11 - Example 2
LEGEND Fig. 11 page 64 1 Insulating material 2 Inspection plug 3 Chimney inspection entrance 4 Minimum safety distance = 0,5 mt 5 Inclination ≥ 3° 6 Level section ≤ 1 mt

Fig. 12 - Example 3

LEGEND Fig. 12 page 64 1 Insulating material 2 Inspection plug 3 Minimum safety distance = 0,5 mt
We recommend to check with your chimney flue manufacturer the safety distances which must be respected and the type of insulating material. The aforesaid regulations are valid also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
Humid pellets cause a bad combustion and running, so please assure you that they are stored in dry places and far at least one meter from the stove and/or any other source of heat.


Fig. 13 - General dimensions

LEGEND Fig. 13 page 66 1 Hole combustion air inlet d.6 cm 2 Exhaust fumes d.8 cm 3 80,3 cm 4 76,5 cm 5 15,8 cm 6 26,8 cm 7 6,5 cm 8 8,5 cm 9 8,2 cm 10 71 cm 11 8,5 cm 12 20,5 cm 13 33 cm

Fig. 14 - General installation with pedestal
LEGEND Fig. 14 page 67 1 Stove 2 Minimum lateral distance = 300 mm 3 Minimum rear distance = 200 mm 4 Minimum front distance = 1000 mm



Fig. 15 - Assembling the pedestal Fig. 16 - Stove on the pedestal
The stove is suitable for wall mounting. The can be attached to a load-bearing wall in masonry (NOT plasterboard, wood, etc...) suitable for the entire weight of the stove.

Fig. 17 - Wall mounting
LEGEND Fig. 17 page 68 1 Stove 2 Minimum lateral distance = 300 mm 3 Minimum front distance = 1000 mm
In some countries also masonring load-bearing walls are considered flammable.


Fig. 18 - Mounting on non-flammable wall
LEGEND Fig. 18 page 69 1 695 mm 2 179 mm 3 260 mm 4 202 mm 5 710 mm 6 206 mm 7 332 mm 8 Wall support 9 Metal plugs 10 Fumes outlet hole d.120 mm 11 Combustion air inlet hole d.80 mm


Fig. 19 - Mounting on flammable wall
LEGEND Fig. 19 page 70 1 695 mm 2 179 mm 3 260 mm 4 202 mm 5 710 mm 6 206 mm 7 332 mm 8 Wall support 9 M8x20 bolt 10 Fumes outlet hole d.120 mm 11 Combustion air inlet hole d.80 mm 12 Spacer (WAL0002 code) 13 Metal plugs 14 735 mm 15 159 mm
Assembly must be carried out by an authorised technician.
For panels installation, proceed as follows:



Fig. 20 - Countersunk screw Fig. 21 - Threaded seat


Fig. 22 - Lower slots Fig. 23 - Lower panel insert


Fig. 24 - Side slots Fig. 25 - Side panels insert


Fig. 26 - Upper slots


Fig. 27 - Glass upper panel Fig. 28 - M5x6 cylinder head screw
A. Proceed as previous steps and fix on the 2 upper slots (see Fig. 26 page 72) no.2 M5x6 cylinder head
screws (see Fig. 27 page 72 and Fig. 28 page 72)

Fig. 29 - Metal upper panel Fig. 30 - M5x10 countersunk screw
Proceed as previous steps and fix on the 2 upper slots (see Fig. 26 page 72) no.2 M5x10 countersunk screws (see Fig. 29 page 72 and Fig. 30 page 72).
Assembly must be carried out by an authorised technician.
For panels installation, proceed as follows:



Fig. 31 - Panels assembly Fig. 32 - Panels fixing
The cable must not get in touch with the fume exhaust pipe and nor with every other part of the stove.

Fig. 33 - Electric socket with master switch


Fig. 34 - Do not cover air slits
Do not cover the hot air outlet slits with any object to avoid stove’s overheating!
The stove is not suitable for food cooking.
This appliance must not be used by people (childreen included) with reduced mobility, psycological deseases or without experience and knowledge except in case of supervision or instruction about the use of the appliance by people responsible for their safety.

Childreen must be constantly overseen in order to assure that they do not play with the appliance.
The stove is provided with a hand rejector: this rejector can be removed exclusively by the stove manufacturer or by the Technical Assistance Service.
During its running, the stove reaches high temperatures: keep away childreen and animals and for your safety please use appropriate fireproof devices, such as heat- protecting gloves.
Set values from 1 to 5 are defined by the manufacturer and they can be changed only by an authorized technician.
Do not use flammable liquids during the ignition (alcool, petrol, oil, etc...).
PANEL ELEMENT DESCRIPTION
P1 and P2: when in set temperature mode, they are useful to increase or decrease the thermostat value from min. 6°C to max 40°C. Keeping pressed P2 key it is possible to see the fume temperature at the exhaust. Both have programming functions.
P3: it enables to enter set temperature and User and Technician parameters menu.
P4: switching on and off, alarm reset and exit from programming.
P5 and P6: increase and decrease the calorific power from 1 to 5.

Chrono: active time programming.
Ignition plug: active ignition.
Auger: active.
Fume fan: active.
Exchanger fan: active.
Alarm: active.

Fig. 35 - LCD control display
LEGEND Fig. 35 page 76 1 Time 2 Power 3 State 4 Message 5 Temperature

By once pressing P3 key you can hace access to user parameter controlling. To let them slide press P5 and P6 keys. They are:
1 FAN ADJUST (supplementary) Module not included in this type of stove.
2 SET CLOCK Set date and time. The board is provided with a lithium battery which enables a clock autonomy of 3/5 years. See CLOCK SETTING page 79.
Press once P3: “CHRONO ENABLE” appears. Press P3 again and with P1 and P2 put in “OFF” or “ON”. For daily, week-end or weekly programming, see DAILY PROGRAMMING page 79. CAUTION: do not active if STAND-BY function is active!
4 SELECT LANGUAGE Press once P3 key and with P1 and P2 keys select the desired language.
It activates a function which, if the set ambient temperature has been exceeded for more then 10 minutes, start the switching off phase up. If the ambient temperature has fall at more than 2°C, the stove will restart automatically up, starting from START UP page 77. Press once P3 key and with P1 and P2 keys put in “OFF” or “ON”. CAUTION: do not activate if CHRONO function is active!
6 BUZZER MODE (audio alarm) Press once P3 key and with P1 and P2 keys put in “OFF” or “ON”.
When the stove has its first ignition, the auger is completely empty. If it should be necessary do a precharge by pressing P3 key, then P1 key for starting up and P4 key for stop.
8 STOVE STATE It shows all parameters connected to the stove state: this is a menu for the Authorized Techinician
9 TECHNICA SETTING Only for the Authorized Technician.
10 SET FLAME It enables to set the flame dipending on the draught of the chimney flue.

Pay attention if the value is positive or negative..
If the pellets do not burn, the failed ignition will be indicated by the alarm “FAILED IGNITION”. • If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for example firelighters cubes).
After a failed ignition the burning pot must be empty from the amassed pellets, before starting the stove up again.
If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.
To check the fume temperature at the exhaust it is sufficient to keep pressed P2 key.

To switch the stove off, keep pressed P4 key: the display shows “FINAL CLEANING”. After about 10 minutes, also the fume fan switches off (this happens always, independently if the stove is hot or cold). Then “OFF” will be shown.
If the pellets are of bad quality (if contains sizing agents, oils, varnishes, plastic remains or if it is mealy), deposits will form along pellets drop pipe during the running. When the stove is switched off, these remains could form little hot coals that rising along the pipe could reach the pellets on the hopper burning them and creating a thick and harmful smoke inside the room. Please always keep the hopper closed with its own lid. If the pipe is sooty, please clean it (see INTRODUCTION page 83).

In case it would be necessary to extinguish the fire emitted by the stove or by the chimney flue, use a fire- extinguisher or contact the firemen. DO NOT use water to extinguish the fire inside the burning pot.


Fig. 36 - Wrong opening of the pellets bag Fig. 37 - Right opening of the pellets bag
The pellet hopper must always be closed with its own lid.

The stove can be operated through a remote control. (Please install 12V N type battery)

Fig. 38 - Remote control
LEGEND Fig. 38 page 81 Button 1 Increase the desired temperature Button 2 Decrease the desired temperature Button 5 Decrease the power level from 1 to 5 Button 6 Increase the power level from 1 to 5 Buttons 1
and 6 Pressed together enable to turn the stove on and off
Safety devices are used to prevent and avoid the risk of damages to people, animales and objects. It is forbidden to execute repearing by no authorized personnel otherwise the warranty and the manufacturer liability fall.
Before of every intervention leave the fire completely extinguish till the cooling and always disconnect the plug from the electric socket.
To the exhaust is connected a probe which contantly controls the temperature during working time.


All these operations must be planned in time with your Autorized Technical Assistance Service.
Before any movement let the fire inside the combustion chamber extinguish till the total cooling and always disconnect the plug from the socket.
The burning pot and ash tray cleaning must be executed at least every 2 days. • Open the door.



Fig. 39 - Burning pot extraction Fig. 40 - Ash tray extraction Fig. 41 - Burning pot cleaning




Fig. 42 - Burning pot box cleaning Fig. 43 - Ash tray box cleaning Fig. 44 - Cleaning with a brush
Per each pellets supply, check the probable presence of meal, sawdust and other remanins on the hopper bottom. If present, they must be removed with the aid of a vacuum cleaner (see Fig. 45 page 84).

Fig. 45 - Hopper and auger cleaning
The hand rejector grid must not ever be removed fron its housing. Clean the hopper bottom and the visible part of the auger exclusively as shown in the picture (see Fig. 45 page 84).

If the auger is blocked by a foreign object (for example: nails), and if it needs to be cleaned, DO NOT remove the hand rejector and DO NOT touch the auger. Please contact the stove manufacturer or the Technical Assistance service of the stove manufacturer.
The hand rejector can be removed exclusively by an authorized technician.
Every 4/8 weeks the fume chamber cleaning must be executed. For CLOE model: remove top panel and then right panel. For SQUARE model: loosen the 2 screws that lock front right panel and remove it.


Fig. 46 - Fume chamber Fig. 47 - Fume chamber cleaning
The exhaust system must be cleaned every month.

Fig. 48 - Fume conduit cleaning

Is it important to hermetically seal the cap to avoid harmful fumes escaping into the room.
Clean every the year the fume fan from ash or dust which can cause a blade unbalance and a greater noise.
As this operation is so delicate it must therefore be executed by an Authorized Technician.



Fig. 49 - Fume fan cleaning: phase1 Fig. 50 - Phase 2 Fig. 51 - Phase 3
Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
As this operation is so delicate it must therefore be executed by an Authorized Technician.

Fig. 52 - Room fan cleaning

Clean the fume passages every year.


Fig. 53 - Remove upper grid Fig. 54 - Remove top cover


Fig. 55 - Fume passages cleaning Fig. 56 - Silicon laying

Clean once a week from soot with brushes. The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This operation must be executed at least once a year.
For cleaning external and inner parts of the stove do not use steel wools, muriatic acid or other corrosive and abrasive materials.
To clean painted metal panels use a soft cloth. Do not use degreasant agents like alcool, diluents, acetone, gasoline because these could irremediably damage the varnish.
Some stove models has an external lining made up of ceramic or stone. These pieces are handmade therefore they could inevitably present crazings, seedinesses, shadings. To clean ceramic or stone panels use a soft and dry cloth. If using any cleaners this will seep through the crazings putting them in evidence.
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in order to guarantee the good running of the stove.
Use exclusively original spare parts.
The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks. The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions.
You should clean the fire door glass every day!

Before of every intervention of the Authorized Technician, the same Technician has the duty to check that the parameters of the mother board correspond with those of the table you own.
In case of doubts regarding the use of the stove, please call ALWAYS the Authorized Technician in order to avoid irreparable damages!
AL 1 - BLACK OUT
Power cut during ignition phase.
Clean the burning pot and switch the stove on again.
Disconnected fume temperature probe Have the stove checked.
Faulty fume temperature probe Replace the fume probe.
Faulty fume probe Replace the fume probe.
Faulty mother board Replace the electronic board.
The exchanger fan does not work Replace the ambient fan.
Too high pellet drop value Adjust the pellet loading.
Faulty protection fuse of the fume fan Replace the fuse (1,25A).
The pellets can burn also thanks to the chimney flue depression and without the aid of the fume fan. Have the fume fan replaced immediately. It can be noxious to health to let the stove running without fume fan.
Faulty fume fan


The burning pot has not been cleaned Clean the burning pot.
Clean the burning pot and switch the stove on again.
Too sever external temperature Start the stove up again.
Humid pellet The pellets must be stored in a dry place. Please check it.
AL 6 - NO PELLET Empty hopper Full the hopper.
Boiler overheating Let the stove cooling. (If the problem persits please call an Authorized Technician).
The ambient exchanger fan does not work Replace the ambient fan.
The lack of tension during the running implies the overheating of the boiler and the intervention of the automatic thermostat. Let the stove cooling and start the stove up again.

The exhaust chimney is partially or totally obstructed. Call en expert stove-repairer who executes a check from the exhaust up to the chimney pot.
The pellet can burn also thanks to the chimney flue depression without the aid of the fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fan.
Fume fan out of order
Obstructed connecting nozzle Clean the connecting nozzle.
Faulty pressostat Replace the pressostat.
Faulty electronic board Replace the mother board.
Contact an expert stove repairer and check that the exhaust chimney is in compliance with regulations: see CHIMNEY FLUE page 56.
In case of strong wind there can be a negative pressure to the chimney. Check and switch the stove on again.
The fire door is not correctly closed
Close the fire door correctly and check if the gaskets are broken.
Fire door microswitch faulty or out of order Replace the fire door microswitch.
Obstructed exhaust · Extreme chimney lenght · Advers whether conditions

Before of every Authorized Technician intervention, the same Technician has the duty to check if the parameters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to avoi irreparable damages!
The stove is without power supply
Check if the plug is connected.
Burned board protection fuse Replace the protection fuse in the board (4A-250V)
Burned protection fuse in the electric socket
Replace the protection fuses in the electric socket (3.15A-250V).
The control display does not switch on
Faulty control display Replace the control display.
Faulty flat cable Replace the flat cable.
Faulty electronic board Replace the mother board.
Empty hopper Full the hopper.
Auger blocked by a foreign object (for example nails)
Clean the auger.
Pellets do not reach the combustion chamber
The auger geared motor is out of order
Replace the geared motor.
Check if on the display there is an “ACTIVE ALARM”
Have the stove checked.

Empty hopper Full the hopper.
Auger blocked by a foreign object (for example nails)
Clean the auger.
The fire extinguish and the stove stops
Bad quality pellets Try other types of pellets.
Pellet drop value too low “phase 1” Adjust the pellet loading.
Check if on the display there is an “ACTIVE ALARM”
Have the stove checked.
Stove running and display showing “BURN POT CLEANING”
Automatica burning pot cleaning
The stove is at minimum, fume fan at maximum. NO PROBLEM!
Check as following: probable obstructions of the combustible air inlet from the back or from the bottom of the stove; burning pot obstructed holes with too ash remains. Have the fan blades and auger cleaned.
Not sufficient combustion air
The exhaust chimney is partially or totally obsturcted. Contact an expert stove-repairer who checks the stove from the exhaust up to the chimney pot. Provide immediately for stove cleaning.
Flames are weak and orange coloured, pellets do not burn properly and the glass blackens
Obstructed stove Provide immediately at the inner cleaning of the stove.
The pellets can burn also thanks to chimney flue depression without the aid of the fume fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fume fan.
The fume fan is out of order
Faulty fume temperature probe
The exchanger fan continues to turn even though the stove has just cooled
Replace the fume probe.
Faulty mother board Replace the mother board.
Faulty or out of order door gaskets
Replace the gaskets.
Ash remains along the stove
Contact an expert stove-repairer who will immediately provide for sealing the junctions with high-temperature silicone and/or for replacing pipes with those in compliance to current regulations. A not sealed fume channelisation can be noxious to health.
Not sealed fume pipes
Obstructed exhaust

The stove runs at minimum. NO PROBLEM!
Stove running and display showing “WORK, MODULATI”
Reached fume outlet limit temperature
The stove runs at minimum. NO PROBLEM!

Fig. 57 - Wiring scheme
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical components. • For fuse replacement in the electric socket which lies on the back of the stove, extract the fuses to change with the aid of a screwdriver in the shutter (see Fig. 58 page 95).
Reached ambient temperature


Fig. 58 - Shutter with the fuse to remove


Fig. 59 - Spare parts


15 CLO5210 CERAMIC GLASS 217x217x4 (SQUARE AND CALDARA MODELS)
21 CLO5412 COLOURED METAL HORIZONTAL TRAPEZIUM PANEL 810x198 (CLOE MODEL)
22 CLO5413 COLOURED METAL VERTICAL TRAPEZIUM PANEL 760x198 (CLOE MODEL)
23 CLO5446 GLASS HORIZONTAL TRAPEZIUM PANEL 815,6x200 (CLOE MODEL)
24 CLO5447 GLASS VERTICAL TRAPEZIUM PANEL 761x200 (CLOE MODEL)
25 CLO5444 SERPENTINE HORIZONTAL TRAPEZIUM PANEL 815,6x200 (CLOE MODEL)
26 CLO5445 SERPENTINE VERTICAL TRAPEZIUM PANEL 761x200 (CLOE MODEL)
The undermentioned information are indicatives and no binding. The manufacturer reserves the ability of bringing modifications of every type with the aim to improve performances.

DESCRIPTION CLOE 6,5 kW SQUARE 6,5 kW
WIDTH 82 cm 82 cm
DEPTH 28,5 cm 27 cm
HEIGHT with pedestal 91,5 cm 92 cm
WEIGHT with pedestal 92-98-107 kg 92-98 kg
INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,3 kW 2,8 - 7,3 kW
NOMINAL THERMIC POWER (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW
EFICIENCY (Min/Max) 88 - 89,5 % 88 - 89,5 %
FUME TEMPERATURE (Min/Max) 129 - 193 °C 129 - 193 °C
FUME MAXIMUM LOADING CAPACITY (Min/Max) 3,4 - 4,4 g/s 3,4 - 4,4 g/s
CO EMISSIONS (13% O2) (Min/Max) 0,049 - 0,010 % 0,049 - 0,010 %
OGC EMISSIONS (13% O2) 0,4 mg/Nm3 0,4 mg/Nm3
NOX EMISSIONS (13% O2) 118 mg/Nm3 118 mg/Nm3
CO2 EMISSIONS (Min/Max) 5,3 - 10,5 % 5,3 - 10,5 %
Medium CO CONTENTS at 13% O2 (Min/Max) 610 - 123 mg/Nm3 610 - 123 mg/Nm3
Medium POWDER CONTENTS at 13% O2 (Max) 16 mg/Nm3 16 mg/Nm3
CHIMNEY DEPRESSION (Min/Max) 11 - 12 Pa 11 - 12 Pa
MINIMUM SAFETY DISTANCE from flammable materials 30 cm 30 cm
FUME OUTLET DIAMETER Ø80 mm Ø80 mm
COMBUSTIBLE Pellet Ø6-7 mm Pellet Ø6-7 mm
PELLETS HEATING VALUE 5 kWh/kg 5 kWh/kg
HEATING VOLUME 18/20°C Coeff. 0,045 kW (Min/ Max) 60 - 156 m3 60 - 156 m3
HOURLY CONSUMPTION (Min/Max) 0,6 - 1,5 kg/h 0,6 - 1,5 kg/h
HOPPER CAPACITY 8 kg 8 kg
RANGE (Min/Max) 13,3 - 5,3 h 13,3 - 5,3 h
SUPPLY 230 V - 50 Hz 230 V - 50 Hz
POWER INPUT (Max) 350 W 350 W
MINIMUM EXTERNAL AIR INLET (last effective area) 80 cm2 80 cm2
EXTERNAL AIR INLET FOR SEALED CHAMBER Ø60 mm Ø60 mm

Fig. 60 - Declaration of Conformity



DESCRIPTION CLOE 6,5 kW SQUARE 6,5 kW
LARGEUR 82 cm 82 cm
PROFONDEUR 28,5 cm 27 cm
HAUTEUR avec piédestal 91,5 cm 92 cm
POIDS avec piédestal 92-98-107 kg 92-98 kg
PUISSANCE THERMIQUE INTRODUITE (Min/Max) 2,8 - 7,3 kW 2,8 - 7,3 kW
PUISSANCE THERMIQUE NOMINALE (Min/Max) 2,5 - 6,5 kW 2,5 - 6,5 kW
EFFICIENCE (Min/Max) 88 - 89,5 % 88 - 89,5 %
TEMPÉRATURE FUMÉES (Min/Max) 129 - 193 °C 129 - 193 °C
DÉBIT MAXIMUM DES FUMÉES 3,4 - 4,4 g/s 3,4 - 4,4 g/s
EMISSIONS CO (13% O2) (Min/Max) 0,049 - 0,010 % 0,049 - 0,010 %
EMISSIONS OGC (13% O2) 0,4 mg/Nm3 0,4 mg/Nm3
EMISSIONS NOX (13% O2) 118 mg/Nm3 118 mg/Nm3
ÉMISSIONS CO2 (Min/Max) 5,3 - 10,5 % 5,3 - 10,5 %
TENEUR moyenne de CO à 13% O2 (Min/Max) 610 - 123 mg/Nm3 610 - 123 mg/Nm3
TENEUR moyenne de POUSSIÈRES à 13% O2 (Max) 16 mg/Nm3 16 mg/Nm3
DÉPRESSION CHEMINÉE (Min/Max) 11 - 12 Pa 11 - 12 Pa
DISTANCE MINIMAL de sécurité du matériel inflammable 30 cm 30 cm
DIAMÈTRE ÉVACUATION FUMÉES Ø80 mm Ø80 mm
COMBUSTIBLE Pellet Ø6-7 mm Pellet Ø6-7 mm
POUVOIR CALORIFIQUE PELLETS 5 kWh/kg 5 kWh/kg
VOLUME RECHAUFFABLE 18/20°C Coefficient 0,045 Kw (Min/Max) 60 - 156 m3 60 - 156 m3
CONSOMMATION HORAIRE (Min/Max) 0,6 - 1,5 kg/h 0,6 - 1,5 kg/h
CAPACITÉ RÉSERVOIR 8 kg 8 kg
AUTONOMIE (Min/Max) 13,3 - 5,3 h 13,3 - 5,3 h
ALIMENTATION 230 V - 50 Hz 230 V - 50 Hz
PUISSANCE ABSORBÉE (Max) 350 W 350 W
MINIMUM PRISE D’AIR EXTÉRIEUR (derniere surface nette) 80 cm2 80 cm2
PRISE D’AIR EXTÉRIEUR POUR CHAMBRE ÉTANCHE Ø60 mm Ø60 mm

FR
Fig. 58 - Déclaration de Conformité


Pagine di riferimento in questo manuale: produttore, supporto e download.
Il significato dei codici di errore mostrati sul display e come cancellarli.
| Codice | Significato | Risolvi | |
|---|---|---|---|
| AL5 | FAILED | p.40 |
Problemi comuni, cause probabili e soluzioni.
| Problema | Possibile causa | Soluzione | |
|---|---|---|---|
| The control display does not switch on | The stove is without power supply | Check if the plug is connected. | p.42 |
| The control display does not switch on | Burned board protection fuse | Replace the protection fuse in the board (4A-250V) | p.42 |
| The control display does not switch on | Burned protection fuse in the electric socket | Replace the protection fuses in the electric socket (3.15A-250V). | p.42 |
| The control display does not switch on | Faulty control display | Replace the control display. | p.42 |
| The control display does not switch on | Faulty flat cable | Replace the flat cable. | p.42 |
| The control display does not switch on | Faulty electronic board | Replace the mother board. | p.42 |
| Pellets do not reach the combustion chamber | Empty hopper | Full the hopper. | p.42 |
| Pellets do not reach the combustion chamber | Auger blocked by a foreign object (for example nails) | Clean the auger. | p.42 |
| Pellets do not reach the combustion chamber | The auger geared motor is out of order | Replace the geared motor. | p.42 |
| Pellets do not reach the combustion chamber | Check if on the display there is an “ACTIVE ALARM” | Have the stove checked. | p.42 |
| The fire extinguish and the stove stops | Empty hopper | Full the hopper. | p.43 |
| The fire extinguish and the stove stops | Auger blocked by a foreign object (for example nails) | Clean the auger. | p.43 |
| The fire extinguish and the stove stops | Bad quality pellets | Try other types of pellets. | p.43 |
| The fire extinguish and the stove stops | Pellet drop value too low “phase 1” | Adjust the pellet loading. | p.43 |
| The fire extinguish and the stove stops | Check if on the display there is an “ACTIVE ALARM” | Have the stove checked. | p.43 |
| Stove running and display showing “BURN POT CLEANING” | Automatica burning pot cleaning | The stove is at minimum, fume fan at maximum. NO PROBLEM! | p.43 |
| Flames are weak and orange coloured, pellets do not burn properly and the glass blackens | Not sufficient combustion air | Check as following: probable obstructions of the combustible air inlet from the back or from the bottom of the stove; burning pot obstructed holes with too ash remains. Have the fan blades and auger cleaned. | p.43 |
| Flames are weak and orange coloured, pellets do not burn properly and the glass blackens | Obstructed exhaust | The exhaust chimney is partially or totally obsturcted. Contact an expert stove-repairer who checks the stove from the exhaust up to the chimney pot. Provide immediately for stove cleaning. | p.43 |
| Flames are weak and orange coloured, pellets do not burn properly and the glass blackens | Obstructed stove | Provide immediately at the inner cleaning of the stove. | p.43 |
| Flames are weak and orange coloured, pellets do not burn properly and the glass blackens | The fume fan is out of order | The pellets can burn also thanks to chimney flue depression without the aid of the fume fan. Have the fume fan immediately replaced. It can be noxious to health to let the stove running without fume fan. | p.43 |
| The exchanger fan continues to turn even though the stove has just cooled | Faulty fume temperature probe | Replace the fume probe. | p.43 |
| The exchanger fan continues to turn even though the stove has just cooled | Faulty mother board | Replace the mother board. | p.43 |
| Ash remains along the stove | Faulty or out of order door gaskets | Replace the gaskets. | p.43 |
| Ash remains along the stove | Not sealed fume pipes | Contact an expert stove-repairer who will immediately provide for sealing the junctions with high-temperature silicone and/or for replacing pipes with those in compliance to current regulations. A not sealed fume channelisation can be noxious to health. | p.43 |
| Stove running and display showing “WORK, MODULATI” | Reached ambient temperature | The stove runs at minimum. NO PROBLEM! | p.44 |
| Stove running and display showing “WORK, MODULATI” | Reached fume outlet limit temperature | The stove runs at minimum. NO PROBLEM! | p.44 |
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.