1. TECHNICAL DATA As a stove of construction type 1, it is possible to connect it to the chimney together with an existing other stove or another hearth for solid fuels, as long as the chimney calculation complies with DIN 4705, Part 3.
Austroflamm Moby diagram (page 1)
Fig. 1
TECHNICAL DATA Height918 mm Width510 mm Depth420 mm Weight130 kg Weight HMS46 kg Flue pipe outlet diameter130 mm Nominal thermal output (EN 13240)5 kW Maximum thermal capacity7 kW Smallest heating capacity2,5 kW Room heating capacity (depending on building insulation)48 - 124 m³
Exhaust values for multiple use of the chimney in accordance with DIN 4705, Part 3 and for the calculation of the chimney measurements in accordance with DIN 4705, Part 2 Fluegas mass flow closed4,21 g/s Fluegas temperature closed302 °C closed Minimum feed pressure Nominal thermal output at 0.8 times n. ther. outp.12 Pa 10 Pa
2. IMPORTANT INFORMATION The installation and operation information given here is of general nature. National and European standards, local and building regulations as well as fire prevention laws must be observed during the operation of the stove. General safety instructions for the operation of your stove Thoroughly read the entire manual before starting up your stove and observe the caution notices.

Do not lay laundry onto the stove for drying. Laundry hung up to dry must be kept at a safe distance from the stove because of the danger of fire.

The woodstove Moby is not suitable for long term heating.

Subject to technical and optical modifications. Formatting and printing errors excepted.

During the operation of your heating unit it is forbidden to use flammable or explosive materials in the same or an adjacent room to the one in which your heating unit is located. The appliance must be operated with the stove door closed.

Your heating unit must not be moved without approved means of transport with sufficient load-bearing capacity.

The stove door and all fittings for adjusting the stove must be closed, if the appliance is out of use. Setting up your stove

Your heating unit is not suitable to be used as a stand or as a ladder.

Austroflamm Moby diagram (page 1)
Fig. 2

Please keep in mind that your stove’s surface heats up considerably during operation. We therefore recommend wearing a safety mitten when operating your stove.

Required safety distances (Minimum distances – see name plate - in Fig. 2) a > 1000 mm (a – toward the front in the radiated area) b > 300 mm c > 200 mm (b – to the side) (c – to the back) Make sure that the room in which the stove is set up has at least one door or window into the outside or is directly adjacent to such a room. Other fireplaces and extractor hoods must not be operated in the same room as the stove. Floor load capacity Make sure that the load capacity of the supporting construction is sufficient to carry the weight of the entire unit, before the heating unit is installed.

Make your children aware of this particular danger and keep them at a distance from the heating unit whenever it is in operation.

Only burn approved fuels and materials listed in the chapter “Clean Burning”.

The burning or placing of flammable or explosive materials, such as empty spray cans, etc. into the firebox as well as the storage of such materials in the immediate vicinity of your heating unit is strictly forbidden due the danger of explosion.

Do not wear loose or flammable clothing when adding fuel to the fire.

Placing non-heat-resistant objects on the heating unit or in the vicinity of the heating unit is forbidden.

english 5 Moby

Page 2 of the Austroflamm Moby user manual — 3. CORRECT OPERATION OF YOUR STOVE
Pagina 2 · clicca per ingrandire
Pagina 2

Combustion air Being the user of the stove you must take care of a sufficient combustion air supply. Sealed-up windows and doors may not allow a sufficient combustion air supply or disturb the draught behaviour of your stove. Please ensure the additional supply of fresh combustion air if necessary. For details please consult your specialist retailer. Make sure that the combustion air intakes are not blocked!

Stove pipe connection For your own safety stringent laws apply for connecting the stove pipes to the chimney. Your professional dealer or distributor knows these laws. Please have your certified retailer carry out the connection of your stove.

3. CORRECT OPERATION OF YOUR STOVE

Approved fuels Dry, well cured and natural wood (hardwood preferred), wood briquettes. Maximum amount of fuel Maximum amount of fuel to be added: 1,5 kg wood or briquettes. Larger amounts of fuel can lead to overheating and thus damage the stove. Clean burning The wood must be dry (relative wood moisture < 15%) and untreated and the right amount of wood must be burned in order to ensure a clean fire that releases only small amounts of emissions. Startup procedures During the first 3-4 operations - at nominal heat output - there may be some odour development and the varnish has not yet hardened. Making a fire For the correct and safe operation of your stove please pay attention of the chimney developing the necessary feed pressure. This must especially be considered before the initial operation (or e.g. after the summer heating break) and during the mid-season heating periods (e.g. at strong wind, etc.). If there is not enough feed pressure, please light only some paper or small kindling first, in order to “warm up” the stove and the chimney. The air inlet must not be covered or closed. Clean grate, empty ash drawer if necessary (watch out for ambers!)! Position the lever for the combustion air to the open (“AUF”) position (see fig. 2 and 4). Place 2-3 logs (approx. 1,0 kg in total) crossways in the combustion chamber (1) with sufficient distance from each other (min. 2 cm), on top of that place some softwood chippings (0,5 kg) (2) and some ignition aid and light (3). (see fig. 3)

Close the door! We recommend to let the first load burn down without changing the air lever position. As soon as no visible flames are left (only embers in the combustion chamber), you can put another load of logs (max. 1,5 kg) in the combustion chamber if desired. When reloading the stove please repeat the procedure as mentioned under “first lighting”: air lever position on “AUF” (= open), open door carefully, place logs, close door.

Austroflamm Moby — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 3

Fig. 4: adjust air lever After a few minutes, when the logs burn well on all sides (bright, high flames – see fig. 5), you can adjust the heat output with the air lever (lever on max. position “AUF” = maximum heat output), the flames should be yellow and never look blueish or have black tips (otherwise add more air) – see fig. 4. Never close air supply completely during operation. (danger of flash-fire!)

The stove door may be opened only for refuelling or disposing of ashes and is to be closed again afterwards.

Austroflamm Moby — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 4
Austroflamm Moby — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 2)
Fig. 5

Figure 3:ignite the fire

Show 4 more labels / short text on this page
Moby 6 english · symbol figures · symbol figures · symbol figures
Page 3 of the Austroflamm Moby user manual — 3. CORRECT OPERATION OF YOUR STOVE
Pagina 3 · clicca per ingrandire
Pagina 3

Heating in-between seasons If you heat the stove in between seasons, when the outside temperatures are higher, the flue gases may not be able to escape completely and this may lead to disturbances in the chimney draught, especially if the temperatures are rising suddenly. The stove has to be charged with less wood then and the primary air has to be increased so that the wood can burn down faster (with visible flames) and thus the chimney draught can stabilize.

Chimney fire A chimney fire may occur, due to sooting and deposits in the chimney, if wrong or humid fuel is used. In case of a chimney fire close all air inlets on the fireplace/chimney immediately and call the fire brigade. Please have an expert inspect your chimney for cracks and air-tightness after the burning out of the chimney.

Austroflamm Moby — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 3)
Fig. 6
Austroflamm Moby — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 3)
Fig. 7
DescriptionNr.drawingPart number Wood retainer, Keramott1719674 Bottom left, Keramott2719668 Bottom right, Keramott3719669 Bottom rear, Keramott4719675 Rear Keramott5719670 Side left, Keramott6719671 Side right Keramott7719672 Baffle plate Keramott8719673

Keramott numbering = installation instructions

Austroflamm Moby — 3. CORRECT OPERATION OF YOUR STOVE diagram (page 3)
Fig. 8
DescriptionNr.drawingPart number Gasket 15x8 mm, L=1800 mm9718571 Gasket flat 10x5 mm, L=1700 mm10718438
DescriptionNr.drawingPart number Door complete11719622 Door handle12719685 Door glass13719616 Glass cleaner ½ litre--640070 Stove lacquer--650002

english 7 Moby

Page 4 of the Austroflamm Moby user manual — problem possible reason solution
Pagina 4 · clicca per ingrandire
Pagina 4

5. SPECIAL FEATURES MOBY Operation with external air supply Moby can be operated with an external air connection. If the combustion air is being supplied directly to the furnace by an air-tight pipe including closing mechanism from the outside, then the stove may be used in residential property with mechanical ventilation. Attention – all gaskets must be inspected periodically for tightness and have to be replaced if necessary. If the stove in being used like that, a multiple stove installation on the same chimney is forbidden.

problem possible reason solution

generally: door glasses must be cleaned with Austroflamm glass cleaner from time to time (depending on the frequency of use)

contact your chimney sweep (elongate chimney/draught metering)

door glass gets sooty too fast

please operate air lever according to user's instructions (if secondary air is closed, the door glass soots rather fast)

incorrect use of the combustion air supply lever

wood logs are too large keep to the max. fuel quantity according to user's instruction

operating temperature was not reached

more fuel, use dry wood (< 15 % residual moisture), attend air regulation

chimney draught not sufficient contact your chimney sweep (elongate chimney/draught metering)

stove does not get enough combustion air

stove is sooted inside more fuel, use dry wood (< 15 % residual moisture), attend air regulation

baking phase of the varnish there may be some odour development during the first operations

stove smells strongly and there is smoke on the outside surface

stove is dusty/dirty cleaning before the heating season starts!

inspect joints and seal up again if necessary

chimney draught no sufficient, flue pipe connection leaky

check chimney draught, examine operating - for info video follow: http://www.austroflamm.com/de/Video/index.html

exhaust gas emission while putting more wood on the fire and during operation

the stove door was opened before the wood has burnt down to embers

put more fuel wood into the combustion chamber only if there are only embers left (no more visible flame)

Moby 8 english · bad chimney draught

Fai una domanda su Austroflamm Moby

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Austroflamm Moby

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Austroflamm Moby manuale in PDF

20 pagine·1.1 MB·Riscaldatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…