INSTALLATION & OPERATIONAL MANUAL GRM SERIES GAS FRYERS MODELS: 1GR35M ML-136407 1GR45M ML-136408 1GR65M ML-136409 1GR85M ML-136410 2GR45MF ML-136417 2GR65MF ML-136418 2GR85MF ML-136419 3GR45MF ML.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY……………………………… ……….
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -5- Check that the followi ng have been included: Crumb Rack Basket Hanger Tank Brush Adjustable Casters (4) two locking, two non- locking for freestanding fryers. Fryer Batteries with the KleenScreen PLUS® Filtration System have casters installed from the factory.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -6- Minimum clearance from noncombustible construction: 0” from the sides of the fryer 0” from the back of the fryer Between the fryer and any open-top flame units: 16” (41 cm) Allow space for servicing and operation.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -7- CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association 178 Rexdale Blvd., Etobicoke, Ontario Canada M9W 1R3. ASSEMBLY The fryer must be restrained to prevent tipping and the splashing of ho t liquid.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -8- Prior to lighting, check all joints in the g as supply line for leaks. Use soap and water solution. Do not use an open flame. After piping has been checked for leaks, fully purge gas pipes to remove air.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -9- In Australia, use only the caster suppl ied by the manufacturer for the fryer device. The fryer must be installed usi ng a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -10- BEFORE FIRST USE Cleaning New units are wiped down at the fa ctory to remove an y visible signs of dirt, oil, grease, etc.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -11- LIGHTING THE PILOT A B A Thermostat Knob B G a s C o n t r o l H a n d l e 1. Open the door. 2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located behind the door.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -12- TURNING ON THE FRYER Set the temperature knob to desired temperature. After the set temperature has been reac hed, the thermostat shuts off the gas flow to burners. The pilot remains lit.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -13- When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket several times. Batter-covered foods should be dropped carefully, one by one, into shortening or basket.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -14- DAILY FILTERING Hot oil and hot parts can cause burns. Use care when operating, cleanin g, and servicing the fryer. Filter shortening at least once a day. Refer to the instructions provided with your filtering equipment.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -15- Use a damp cloth with warm water and a mild soap or detergent. Do not use chlorine or sulfate/sulfide cleaners.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -16- KleenScreen PLUS ® Filtration System Installation and Operational Manual For GRMF and 2XGMF Models 2GR45MF Shown GAS KleenScreen.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -17- Filtering Instructions for KleenScreen PLUS ® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be dr ained and filtered at a time.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -18- Fully assembled filter screen assembly: F i g . 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -19- INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS ® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RA TE WE RECOMME ND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -20- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -21- 4. Drain the oil out of the fry tank by turning t he red handle drain valve. The filter pan will begin to fill with oil. When the oil level fills half of the filter pan, pull the red handled filter lever towards you.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -22- FLUSH AND DISCARD: 1. Follow filtering instructions 1-3, however do not put oil treatment media into the fryer.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -23- THERMAL OVERLOAD PROTECTION BUTTON: The motor/pump supplied wi th the filtering system has a thermal overload protec tion circuit that senses when excess heat occurs due to filtering for long periods of time or under heavy load prior to discarding debris buildup.
GRM SERIES GAS FRYERS VULCAN-HART F-312 33 Rev. F (Janu ary 2008) -24- Troubleshooting Chart: Problem: Probable Cause: No Heat: Thermostat dial not turned on.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Vulcan-Hart ML-136409 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Vulcan-Hart ML-136409 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Vulcan-Hart ML-136409 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Vulcan-Hart ML-136409 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Vulcan-Hart ML-136409, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Vulcan-Hart ML-136409.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Vulcan-Hart ML-136409. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Vulcan-Hart ML-136409 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.